Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 12: Fire resistance of composite doors

EXAP standard specific to the materials typically used within composite fire and smoke control doors.

Erweiterte Anwendung von Prüfergebnissen zur Feuerwiderstandsfähigkeit und/oder Rauchdichtigkeit von Türen, Toren und zu öffnenden Fenstern einschließlich ihrer Baubeschläge - Teil 12: Feuerwiderstandsfähigkeit von Verbundtüren

Dieses Dokument behandelt Dreh- und Schwenktüren sowie Türen mit Türblättern aus Verbund-/Polymer werkstoffen und/oder Türzargen aus Verbund-/Polymerwerkstoffen. Dieses Dokument behandelt außerdem holzbasierte Türblätter, die in Türzargen aus Verbund-/Polymerwerkstoffen eingehängt sind. Verbundtüren, mit einem oder beiden Türblättern oder der Türzarge aus Verbund-/Polymerwerkstoff werden in diesem Dokument behandelt. Es schreibt die Methodologie zur Erweiterung der Anwendung von Ergebnissen der Prüfung(en) der Feuerwiderstandsfähigkeit nach EN1634-1 und/oder EN1634-3 vor. Dieses Dokument behandelt Türen aus Verbund-/Polymerwerkstoffen.
In Abhängigkeit von der Durchführung der entsprechenden Prüfung oder Prüfungen kann die erweiterte Anwendung alle oder einige der folgenden Beispiele abdecken:
- Integrität (E), Integrität & Strahlung (EW) oder Integrität & Isolierung (EI1 oder EI2) & Sa (Sa3 oder Sa4) Umgebungstemperatur-Rauchdichtheitsklassifizierungen;
- verglaste Elemente einschließlich Sichtfenster und gerahmte verglaste Türen;
- verglaste Seitenteile oder Türoberlichter, die durch Querträger/Pfosten oder gekoppelte Türzargen verbunden sind;
- massive (undurchsichtige) Seitenteile oder obere Türblenden, die durch Querträger/Pfosten oder gekoppelte Türzargen verbunden sind;
- Baubeschläge;
- dekorative Beschichtungen;
- dämmschichtbildende Dichtungen, sowie Dichtungen zur Behinderung von Rauchdurchtritt (Rauchschutz
dichtungen), Durchzug oder der Schallübertragung (Schallschutzdichtungen);
- alternative Stützkonstruktion(en) und Befestigungsmethoden.
Die Auswirkung auf eine „C“-Klassifizierung für Türen im Rahmen eines erweiterten Anwendungsprozesses wird nicht in diesem Dokument behandelt.
Dieses Dokument behandelt keine horizontalen Türen.
Siehe BildA.1 mit Darstellungen von Beispielen für durch dieses Dokument behandelte Verbundtüren.

Razširjena uporaba rezultatov preskusov požarne odpornosti in/ali dimotesnosti za vrata, zaporne elemente in okna, ki se odpirajo, vključno z njihovim okovjem - 12. del: Požarna odpornost kompozitnih vrat

General Information

Status
Not Published
Public Enquiry End Date
30-Oct-2025
Technical Committee
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
01-Sep-2025
Due Date
19-Jan-2026

Buy Standard

Draft
prEN 15269-12:2025
English language
308 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2025
Razširjena uporaba rezultatov preskusov požarne odpornosti in/ali dimotesnosti
za vrata, zaporne elemente in okna, ki se odpirajo, vključno z njihovim okovjem -
12. del: Požarna odpornost kompozitnih vrat
Extended application of test results for fire resistance and/or smoke control for door,
shutter and openable window assemblies, including their elements of building hardware -
Part 12: Fire resistance of composite doors
Erweiterte Anwendung von Prüfergebnissen zur Feuerwiderstandsfähigkeit und/oder
Rauchdichtigkeit von Türen, Toren und zu öffnenden Fenstern einschließlich ihrer
Baubeschläge - Teil 12: Feuerwiderstandsfähigkeit von Verbundtüren
Ta slovenski standard je istoveten z: prEN 15269-12
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
91.060.50 Vrata in okna Doors and windows
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
August 2025
ICS
English Version
Extended application of test results for fire resistance
and/or smoke control for door, shutter and openable
window assemblies, including their elements of building
hardware - Part 12: Fire resistance of composite doors
Erweiterte Anwendung von Prüfergebnissen zur
Feuerwiderstandsfähigkeit und/oder Rauchdichtigkeit
von Türen, Toren und zu öffnenden Fenstern
einschließlich ihrer Baubeschläge - Teil 12:
Feuerwiderstandsfähigkeit von Verbundtüren
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 127.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 15269-12:2025 E
worldwide for CEN national Members.

Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 7
3 Terms and definitions . 7
4 Determination of the field of extended application . 11
4.1 General. 11
4.2 How to use the extended application rules in Annex A . 11
4.3 Procedure for maximum field of extended application . 13
4.4 Analysis of test results . 13
5 Extended application report . 13
6 Classification report. 14
Annex A (normative) Construction parameter variations . 15
Annex B (normative) Primary test requirements (hierarchy) . 274
B.1 Door Types Permitted: . 274
B.2 Primary test requirements (hierarchy) figures. 275
Annex C (normative) Primary test requirements (hierarchy) . 282
C.1 Door Types Permitted: . 282
C.2 Primary test requirements (hierarchy) figures. 283
Annex D (normative) Secondary test requirements (hierarchy) . 289
D.1 Door Types Permitted: . 289
D.2 The following figures detail the permitted designs based on successful testing. Testing
shall be undertaken for Fire Resistance to EN 1634-1 and / or Ambient Temperature
Smoke Control to EN 1634-3 where applicable to the classification desired from the
product family. . 289
D.3 Where a test undertaken on the left most design within the figures has been
successful it is permitted to cover the doorset style to the right of the figure
downstream. Testing shall be undertaken on the door leaf design which exhibited the
highest level of deflection within the primary testing undertaken. The configurations
achieved within the secondary testing may be applied to both glazed and unglazed
leaves covered by the primary testing which were deemed less onerous than the one
tested. Primary testing as detailed within Annex B or C shall be undertaken to
establish the range applicable for the product family including solid and / or glazed
leaves. . 289
D.4 The X shown in the following figures indicates that the bottom aperture may be tested
as a glazed or a solid panel. If tested glazed then the same glazing system shall be used
to cover the relevant doorset styles to the right of the figure downstream. If tested as
a solid panel, then the same solid panel system shall be used to cover the relevant
doorset styles to the right of the figure downstream. Testing X as a glazed aperture
does not cover a solid panel and vice versa. . 289
Bibliography . 308

Table A.2 - Construction parameter variations - Section AB - Composite leaf – fixed size sub-frame 52
Table A.3 - Construction parameter variations - Section AC - Timber door leaf – made from a single sheet
of material without a sub-frame     85
Table A.4 - Construction parameter variations - Section AD - Composite leaf – PVC-U  119
Table A.5 - Construction parameter variations - Section B – Door frame   152
Table A.6 - Construction parameter variations - Section C – Hardware   171
Table A.7 - Construction parameter variations - Section D - Side / Overpanels (glazed and panelled) –
Transomed and Coupled      238
Table A.8 - Construction parameter variations - Section E – Glazing for door leaf  254
Table A.9 - Construction parameter variations - Section F - Supporting Construction and Attachment
(Technique) of door frame and /or side / over panels / fanlights   265

European foreword
This document (prEN 15269-12:2025) has been prepared by Technical Committee CEN/TC 127 “Fire
safety in buildings”, the secretariat of which is held by BSI.
This document is currently submitted to the CEN Enquiry.

1 Scope
This document covers hinged or pivoted doorsets and door assemblies with composite/polymeric based
leaves and / or composite/polymeric door frames. This document also covers timber-based door leaves
hung within composite / polymeric door frames. Composite doorsets with both or either the leaf or the
frame manufactured from a composite/polymeric material are covered by this document. It prescribes
the methodology for extending the application of test results obtained from fire resistance test(s)
conducted in accordance with EN 1634-1 and / or EN 1634-3. This document covers doorsets with
elements which are comprised of composite / polymeric material.
Subject to the completion of the appropriate test or tests, the extended application can cover all or some
of the following examples:
— integrity (E), integrity & radiation (EW) or integrity & insulation (EI or EI ) & Sa (S or S )
1 2 a3 a4
ambient temperature smoke control classifications;
— Glazed elements including vision panels and framed glazed doorsets;
— Glazed sidepanel or fanlight connected by transom/mullion or coupled frames;
— Solid (Non vision) sidepanel, or overpanel connected by transom/mullion or coupled frames;
— Items of building hardware;
— Decorative finishes;
— Intumescent, smoke, draught or acoustic seals;
— Alternative supporting construction(s) and fixing techniques.
The effect on the Classification ‘C’ for the doorsets following an extended application process is not
addressed in this document.
This document does not cover horizontal doorsets.
Refer to figure A.1 for example illustrations of composite doorsets covered by this document.

Composite door frame with composite door leaf:

Composite door frame with timber based door leaf:

Timber door frame with composite door leaf:

Metal door frame with composite door leaf:

Key
1 A composite door leaf as defined in section 3.
Figure A.1 — Composite doorsets covered by this document
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 1363-1, Fire resistance tests — Part 1: General requirements
EN 1634-1, Fire resistance and smoke control tests for door, shutter and openable window assemblies and
elements of building hardware — Part 1: Fire resistance test for doors, shutters and openable windows
EN 1634-3, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and
elements of building hardware – Part 3: Smoke control test for door and shutter assemblies.
EN 12519, Windows and pedestrian doors — Terminology
EN 15269-1, Extended application of test results for fire resistance and/or smoke control for door, shutter
and openable window assemblies, including their elements of building hardware — Part 1: General
Requirements
EN 15725, Extended application reports on the fire performance of construction products and building
elements
EN ISO 13943, Fire safety — Vocabulary (ISO 13943)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 1363-1, EN 12519, EN ISO
13943, EN 1634-1, EN 1634-3 and EN 15269-1, EN 15725 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp/
— IEC Electropedia: available at https://www.electropedia.org/
3.1
door frame
part of the doorset or door assembly from which the door leaf is supported and to which the door leaf is
hinged
Note 1 to entry: The door frame may also be used to support glazed sidepanels or fanlights or overpanels
3.2
door leaf
hinged or pivoted part within the door frame of a door assembly or doorset
3.3
glazing cassette
glass retention components used as a glazing system to secure and position a glass in a composite door
leaf or panel
3.4
composite doorset
hinged or pivoted doorset with non-cellulosic polymeric based leaf, with or without glazing in the leaf,
and/or a non-cellulosic polymeric door frame
Note 1 to entry: A timber/cellulosic-based door leaf hung within a non-cellulosic polymeric door frame is also
considered a composite doorset within this document
Note 2 to entry: A doorset with a non-cellulosic polymeric based door leaf hung within a timber/cellulosic or metal
door frame is also considered a composite doorset within this document
Note 3 to entry: A composite doorset may be ei
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.