Metal halide lamps - Performance specification

CM to be merged with PR=24308

Halogen-Metalldampflampen - Anforderungen an die Arbeitsweise

Lampes aux halogénures métalliques - Spécifications de performance

Sijalke s kovinskim halidom - Tehnična specifikacija - Dopolnilo AA

General Information

Status
Not Published
Public Enquiry End Date
31-Dec-2015
Current Stage
98 - Abandoned project (Adopted Project)
Start Date
14-Oct-2019
Due Date
19-Oct-2019
Completion Date
14-Oct-2019

Relations

Buy Standard

Draft
k FprEN 61167:2014/oprAA:2015
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
kSIST FprEN 61167:2014/oprAA:2015
01-december-2015
6LMDONHVNRYLQVNLPKDOLGRP7HKQLþQDVSHFLILNDFLMD'RSROQLOR$$
Metal halide lamps - Performance specification
Halogen-Metalldampflampen - Anforderungen an die Arbeitsweise
Lampes aux halogénures métalliques - Spécifications de performance
Ta slovenski standard je istoveten z: FprEN 61167:2014/prAA:2015
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
kSIST FprEN 61167:2014/oprAA:2015 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

kSIST FprEN 61167:2014/oprAA:2015

---------------------- Page: 2 ----------------------

kSIST FprEN 61167:2014/oprAA:2015

EUROPEAN STANDARD DRAFT
FprEN 61167:2014
NORME EUROPÉENNE

EUROPÄISCHE NORM
prAA
October 2015
ICS 29.140.30
English Version
Metal halide lamps - Performance specification
Lampes aux halogénures métalliques - Spécifications de Halogen-Metalldampflampen - Anforderungen an die
performance Arbeitsweise
This draft amendment prAA, if approved, will modify the European Standard FprEN 61167:2014; it is submitted to CENELEC members for
enquiry.
Deadline for CENELEC: 2016-01-29.

It has been drawn up by CLC/TC 34A.

If this draft becomes an amendment, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

This draft amendment was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 58960 Ref. No. FprEN 61167:2014/prAA:2015 E

---------------------- Page: 3 ----------------------

kSIST FprEN 61167:2014/oprAA:2015
FprEN 61167:2014/prAA:2015
1 European foreword
2 This draft amendment to the draft European Standard FprEN 61167:2014 was prepared by
3 CLC/TC 34A “Lamps”. It contains common modifications to 34A/1809/FDIS (IEC 61167:2015) and is
4 submitted to the Enquiry.
5 If approved, this draft amendment will be merged together with EN 61167:201X and both drafts will be
6 published as one single document, i.e. EN 61167:201X (based on IEC 61167:2015, modified), with the
7 implementation dates of this FprAA.
8 The following dates are proposed:
– latest date by which the existence of this document has to be (doa) dor + 6 months
announced at national level
– latest date by which this document has to be implemented at (dop) dor + 12 months
national level by publication of an identical
national standard or by endorsement
– latest date by which the national standards conflicting with this (dow) dor + 36 months
document have to be withdrawn (to be confirmed or
modified when voting)
9 EN 61167:201X will supersede EN 61167:2011.
10 Clauses, subclauses, notes, tables, figures and annexes which are additional to those in
11 IEC 61167:2015 are prefixed “Z”.
12 For the relationship with EU Directives see informative Annexes ZZA, ZZB and ZZC, which are integral
13 parts of this document.
14 This standard provides test methods related to parameters as prescribed by EC Regulation 245/2009,
15 EU Regulation 1194/2012 and EU Regulation 874/2012 while conformity assessment (sampling,
16 conformity procedures as well as limits) for market surveillance are specified in the text of the above
17 Regulations.
18
2

---------------------- Page: 4 ----------------------

kSIST FprEN 61167:2014/oprAA:2015
FprEN 61167:2014/prAA:2015
19 Text of prAA to FprEN 61167
20 The text of this draft European Amendment consists of the text of the International Standard
21 IEC 61167:2015 (34A/1809/FDIS) with the following common modifications:
22 COMMON MODIFICATIONS
23 CONTENTS Add the following annexes:
24 Annex ZA (normative) Normative references to international publications with
25 their corresponding European publications
26 Annex ZZA (informative) Relationship between this European Standard and the
27 requirements of Commission Regulation (EC) No 245/2009
28 Annex ZZB (informative) Relationship between this European Standard and the
29 requirements of Commission Regulation (EU) No 1194/2012
30 Annex ZZC (informative) Relationship between this European Standard and the
31 requirements of Commission Regulation (EU) No 874/2012
32
33 Add the following clause before Clause 2
34 Z1 Overall statement
35 Where a Commission Regulation specifies limits for parameters these limits shall be
36 used instead of the limits specified in this standard.
37 3 Terms and definitions
38 After 3.18 add new definitions 3.Z1 up to 3.Z7:
39 3.Z1
40 directional lamp
41 lamp having at least 80 % light output within a solid angle of π sr (corresponding to a
42 cone with angle of 120°)
43 [SOURCE: Regulation 1194/2012, Article 2]
44 3.Z2
45 beam angle
46 the angle between two imaginary lines in a plane through the optical beam axis, such
47 that these lines pass through the centre of the front face of the lamp and through
48 points at which the luminous intensity is 50 % of the centre beam intensity
49 [SOURCE: EN 61341]
50 3.Z3
51 partial luminous flux (of a light source, within a specified cone angle)
52 total luminous flux emitted from a light source within a specified cone angle α
53 determined from the luminous intensity distribution I(θ, φ) of the source:
2π α / 2
54 = I(θ,ϕ)sinθdθdϕ (2)
α
∫ ∫
ϕ=0θ=0
55 Note 1 to entry: Partial luminous flux is expressed in lumen (lm)
56 Note 2 to entry: (θ, φ)=(0,0) is the direction of the cone axis
57 Note 3 to entry: The cone angle α is the full angle (diameter) of the cone
58 [SOURCE: EN 13032-4, 3.41, modified, – Notes 4 and 5 removed]
3

Φ

---------------------- Page: 5 ----------------------

kSIST FprEN 61167:2014/oprAA:2015
FprEN 61167:2014/prAA:2015
59 3.Z4
60 useful luminous flux, Φuse
61 partial luminous flux of a lamp falling within the cone used for calculating the lamp’s
62 energy efficiency according Annex III, point 1.1 of regulation (EU) No 1194/2012
63 Note 1 to entry: Useful luminous flux is expressed in lumen (lm).
64 Note 2 to entry: The regulation specifies 90° or 120° cones according to the product characteristics.
65  Note 3 to entry: Useful luminous flux is similar to partial luminous flux. It is determined with the cone
66 axis coincident with the observed optical beam axis of the light source, the axis about which the luminous
67 intensity is substantially symmetrical.
68 3.Z5
69 efficacy
70 ‘luminous efficacy of a source’, ‘light source efficacy’ or ‘lamp efficacy’
71 (ηsource)
72 means the quotient of the luminous flux emitted (Ф) by the power consumed by the
73 source (Psource). ηsource = Ф / Psource. Unit: lm/W.
74 The power dissipated by auxiliary equipment such as ballasts is not included in the
75 power consumed by the source
76 [SOURCE: Regulation 245/2009 Annex II, 1.a)]
77 3.Z6
78 Lamp Lumen Maintenance Factor (LLMF)
79 means the ratio of the luminous flux emitted by the lamp at a given time in its life to the
80 initial luminous flux
81 [SOURCE: Regulation 245/2009 Annex II, 1.b)]
82 3.Z7
83 Lamp Survival Factor (LSF)
84 means the fraction of the total number of lamps which continue to operate at a given
85 time under defined conditions and switching frequency
86 [SOURCE: Regulation 245/2009 Annex II, 1.c)]
87 4 Lamp requirements
88 4.2 Marking
89 Add the following paragraph at the end of 4.2
90 Where a lamp is to be considered as a special purpose product according to
91 Regulation (EC) No 1194/2012 this shall be declared by the supplier.
92 4.8.4 Requirements and test conditions
93 Replace “Under consideration” with the following new text:
94 The chromaticity coordinates and correlated colour temperature of an individual lamp
95 shall be calculated according to CIE 15 from a measurement made under the
96 conditions of Annex B or Annex E as appropriate
97 The colour rendering index of an individual lamp shall be calculated according to
98 CIE 13.3 from a measurement made under the conditions of Annex B or Annex E as
99 appropriate.
4

---------------------- Page: 6 ----------------------

kSIST FprEN 61167:2014/oprAA:2015
FprEN 61167:2014/prAA:2015
100 4.Z1 After Subclause 4.7 add new Subclause 4.Z1 as follows:
101 4.Z1 Useful luminous flux
102 The useful luminous flux of a directional lamp shall be measured under the conditions
103 of Annex A or Annex E as appropriate, by luminous intensity integration as described
104 in EN 13032-4 , 6.3 "Partial luminous flux".
105 Alternative measurement methods may be used if they can be shown to give
106 equivalent results for the product being tested, if necessary by applying correction
107 factors. Measurements with lamps operating horizontally are often much easier to
108 carry out. The reference method, however, uses the measurement position according
109 to A.1.
110 In case of doubt a goniophotometry measurement of EN 13032-4 clause 6.3 shall be
111 used.
112 NOTE  Below are a few examples of alternative measurement methods. It is not an exhaustive list.
113 • For small beam angles shine into integrating sphere.
114 • Mount lamp on internal surface of integrating sphere.
115 • Mount lamp inside integrating sphere with screening (LM-20 technique).
116 • Illuminate a surface and measure the illuminance across the surface with a photometer.
117 • Illuminate a surface and measure the surface luminance with a luminance camera.
118 • Illuminate a translucent screen and measure the surface luminance of the rear side with a
119 luminance camera
120 4.Z2 After 4.9 add new Subclauses 4.Z2 up to 4.Z5 as follows:
121 4.Z2
122 The efficacy of an individual lamp shall be calculated from a measurement of luminous
123 flux and power according to the conditions of Annex B or Annex E as appropriate.
124 4.Z3
125 The lamp lumen maintenance factor of an individual lamp shall be calculated from
126 measurements of its luminous flux made at appropriate times according to the
127 conditions of Annex B or Annex E as appropriate. Lamp operation between these
128 measurements shall be as prescribed in Annex C.
129 4.Z4
130 The survival of an individual lamp shall be determined by
...

Questions, Comments and Discussion