Metal halide lamps - Performance specification (IEC 61167:2018)
This document specifies the performance requirements for metal halide lamps for general
lighting purposes.
For some of the requirements given in this document, reference is made to “the relevant lamp
data sheet”. For some lamps, these data sheets are contained in this document. For other
lamps, falling under the scope of this document, the relevant data are supplied by the lamp
manufacturer or responsible vendor.
The requirements of this document relate only to type testing.
The requirements and tolerances specified in this document correspond to testing of a type
test sample submitted by the manufacturer for that purpose. In principle this type test sample
consists of units having characteristics typical of the manufacturer’s production and being as
close to the production centre point values as possible.
It can be expected that with the tolerances given in this document, the product manufactured
in accordance with the type test sample will comply with this document for the majority of
production. Due to the production spread however, it is inevitable that there will sometimes be
products outside the specified tolerances. For guidance on sampling plans and procedures for
inspection by attributes, see ISO 2859-10.
Halogen-Metalldampflampen - Anforderungen an die Arbeitsweise
Lampe aux halogénures métalliques - Spécification de performances (IEC 61167:2018)
L'IEC 61167:2018 spécifie les exigences de performances applicables aux lampes aux halogénures métalliques pour les applications d'éclairage générales.
Cette quatrième édition annule et remplace la troisième édition parue en 2015. Cette édition constitue une révision technique.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente.
a) Un ensemble de nouvelles fiches techniques sur les lampes a été introduit pour les types de lampes conçus pour remplacer les lampes à vapeur de sodium à haute pression.
b) Un ensemble de nouvelles fiches techniques sur les lampes a été introduit pour les versions 4 200 K des types de lampes à 3 000 K déjà présents dans la norme.
c) Un ensemble de nouvelles fiches techniques sur les lampes a été introduit pour les nouveaux types de lampes pour lesquels les données d'amorçage à haute fréquence sont importantes.
d) L'Annexe G a été révisée pour intégrer l'amorçage à haute fréquence. A la suite de cette modification, toutes les fiches techniques de la norme ont été révisées et ont reçu un nouveau format.
e) Une nouvelle annexe informative, l'Annexe K, a été introduite pour indiquer des méthodes recommandées de mesurage de la température des lampes.
Sijalke s kovinskim halidom - Tehnična specifikacija (IEC 61167:2018)
Ta dokument določa zahteve glede zmogljivosti za sijalke s kovinskim halidom za splošno razsvetljavo.
Pri nekaterih zahtevah iz tega dokumenta je omenjen »tehnični list ustrezne sijalke«. Tehnični listi za nekatere sijalke so vključeni v ta dokument. Ustrezne podatke za druge sijalke, ki sodijo na področje uporabe tega dokumenta, zagotovi njihov proizvajalec ali odgovorni prodajalec.
Zahteve iz tega dokumenta se nanašajo samo na tipsko preskušanje.
Zahteve in tolerance, ki so opredeljene v tem dokumentu, ustrezajo rezultatom tipskega preskušanja vzorca, ki ga proizvajalec predloži za ta namen. Ta preskusni vzorec načeloma vsebuje enote z lastnostmi, ki so značilne za proizvajalčev izdelek, in katerih vrednosti so kar se da podobne središčnim vrednostim proizvedenih izdelkov.
S tolerancami, podanimi v tem dokumentu, se lahko pričakuje, da bo večina primerkov izdelka, ki je proizveden v skladu z vzorcem za tipsko preskušanje, skladna s tem dokumentom. Vendar zaradi razpršene proizvodnje ni mogoče zagotoviti, da bi bili vsi izdelki znotraj določenih toleranc. Za smernice glede načrtov vzorčenja in postopkov za kontrolo po opisnih spremenljivkah glej standard ISO 2859-10.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61167:2019
01-januar-2019
1DGRPHãþD
SIST EN 61167:2016
6LMDONHVNRYLQVNLPKDOLGRP7HKQLþQDVSHFLILNDFLMD,(&
Metal halide lamps - Performance specification (IEC 61167:2018)
Lampe aux halogénures métalliques - Spécification de performances (IEC 61167:2018)
Ta slovenski standard je istoveten z: EN 61167:2018
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
SIST EN 61167:2019 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 61167:2019
---------------------- Page: 2 ----------------------
SIST EN 61167:2019
EUROPEAN STANDARD EN 61167
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2018
ICS 29.140.30 Supersedes EN 61167:2016
English Version
Metal halide lamps - Performance specification
(IEC 61167:2018 , modified)
Lampes aux halogénures métalliques - Spécification de Halogen-Metalldampflampen - Anforderungen an die
performances Arbeitsweise
(IEC 61167:2018 , modifiée) (IEC 61167:2018 , modifiziert)
This European Standard was approved by CENELEC on 2018-06-01. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61167:2018 E
---------------------- Page: 3 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
European foreword
The text of document 34A/2051/FDIS, future edition 4 of IEC 61167, prepared by IEC/SC 34A "Lamps"
of IEC/TC 34 "Lamps and related equipment" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 61167:2018.
A draft amendment, which covers common modifications to IEC 61167 (34A/2051/FDIS), was
prepared by CLC/TC 34A “Lamps” and approved by CENELEC.
The following dates are fixed:
• latest date by which this document has to be (dop) 2019-05-02
implemented at national level by publication
of an identical national standard or by
endorsement
• latest date by which the national standards (dow) 2021-11-02
conflicting with this document have to be
withdrawn
EN 61167:2018 supersedes EN 61167:2016.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Clauses, subclauses, notes, tables, figures and annexes which are additional to those in
IEC 61167:2018 are prefixed “Z”.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association, and supports essential requirements of EU Directives.
For the relationship with EU Directives see informative Annexes ZZA, ZZB and ZZC, which are integral
parts of this document.
This standard provides test methods related to parameters as prescribed by EC Regulation 245/2009,
EU Regulation 1194/2012 and EU Regulation 874/2012 while conformity assessment (sampling,
conformity procedures as well as limits) for market surveillance are specified in the text of the above
Regulations.
Endorsement notice
The text of the International Standard IEC 61167:2018 was approved by CENELEC as a European
Standard with agreed common modifications.
COMMON MODIFICATIONS
CONTENTS Add the following annexes:
Annex ZA (normative) Normative references to international publications with
their corresponding European publications
Annex ZZA (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EC) No 245/2009
Annex ZZB (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EU) No 1194/2012
Annex ZZC (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EU) No 874/2012
2
---------------------- Page: 4 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
Add the following clause before Clause 2:
Z1 Overall statement
Where a Commission Regulation specifies limits for parameters these limits shall be
used instead of the limits specified in this standard.
3 Terms and definitions
After 3.18 add new definitions 3.Z1 up to 3.Z7:
3.Z1
directional lamp
lamp having at least 80 % light output within a solid angle of π sr (corresponding to a
cone with angle of 120°)
[SOURCE: Regulation 1194/2012, Article 2]
3.Z2
beam angle
angle between two imaginary lines in a plane through the optical beam axis, such that
these lines pass through the centre of the front face of the lamp and through points at
which the luminous intensity is 50 % of the centre beam intensity
[SOURCE: EN 61341]
3.Z3
partial luminous flux (of a light source, within a specified cone angle)
luminous flux emitted from a light source within a specified cone angle α determined
from the luminous intensity distribution I(θ, φ) of the source:
2π α / 2
= I(θ,ϕ)sinθdθdϕ (2)
α
∫ ∫
ϕ=0θ=0
Note 1 to entry: Partial luminous flux is expressed in lumen (lm).
Note 2 to entry: (θ, φ)=(0,0) is the direction of the cone axis.
Note 3 to entry: The cone angle α is the full angle (diameter) of the cone.
[SOURCE: EN 13032-4:2015, 3.41, modified, – Notes 4 and 5 removed]
3
Φ
---------------------- Page: 5 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
3.Z4
useful luminous flux, Φuse
partial luminous flux of a lamp falling within the cone used for calculating the lamp’s
energy efficiency according Annex III, point 1.1 of regulation (EU) No 1194/2012
Note 1 to entry: Useful luminous flux is expressed in lumen (lm).
Note 2 to entry: The regulation specifies 90° or 120° cones according to the product characteristics.
Note 3 to entry: Useful luminous flux is similar to partial luminous flux. It is determined with the cone axis
coincident with the observed optical beam axis of the light source, the axis about which the luminous
intensity is substantially symmetrical.
3.Z5
efficacy
‘luminous efficacy of a source’, ‘light source efficacy’ or ‘lamp efficacy’
(ηsource)
quotient of the luminous flux emitted (Ф) by the power consumed by the source
(Psource). ηsource = Ф / Psource. Unit: lm/W.
The power dissipated by auxiliary equipment such as ballasts is not included in the
power consumed by the source
[SOURCE: Regulation 245/2009 Annex II, 1.a)]
3.Z6
Lamp Lumen Maintenance Factor (LLMF)
ratio of the luminous flux emitted by the lamp at a given time in its life to the initial
luminous flux
[SOURCE: Regulation 245/2009 Annex II, 1.b)]
3.Z7
Lamp Survival Factor (LSF)
fraction of the total number of lamps which continue to operate at a given time under
defined conditions and switching frequency
[SOURCE: Regulation 245/2009 Annex II, 1.c)]
4 Lamp requirements
4.2 Marking
Add the following new sub-clause after 4.2.2
4.2.Z1 Special purpose product
Where a lamp is to be considered as a special purpose product according to
Regulation (EC) No 1194/2012 this shall be declared by the supplier.
4.8.4 Requirements and test conditions
Replace “Under consideration” with the following new text:
The chromaticity coordinates and correlated colour temperature of an individual lamp
shall be calculated according to CIE 15 from a measurement made under the
conditions of Annex B or Annex E as appropriate.
4
---------------------- Page: 6 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
The colour rendering index of an individual lamp shall be calculated according to
CIE 13.3 from a measurement made under the conditions of Annex B or Annex E as
appropriate.
4.Z1 After sub-clause 4.7 add new sub-clause 4.Z1 as follows:
4.Z1 Useful luminous flux
The useful luminous flux of a directional lamp shall be measured under the conditions
of Annex B or Annex E as appropriate, by luminous intensity integration as described
in EN 13032-4:2015, 6.3 "Partial luminous flux".
Alternative measurement methods may be used if they can be shown to give
equivalent results for the product being tested, if necessary by applying correction
factors. Measurements with lamps operating horizontally are often much easier to
carry out. The reference method, however, uses the measurement position according
to A.1.
In case of doubt a goniophotometry measurement of EN 13032-4:2015, 6.3 shall be
used.
NOTE Below are a few examples of alternative measurement methods. It is not an exhaustive list.
• For small beam angles shine into integrating sphere.
• Mount lamp on internal surface of integrating sphere.
• Mount lamp inside integrating sphere with screening (LM-20 technique).
• Illuminate a surface and measure the illuminance across the surface with a photometer.
• Illuminate a surface and measure the surface luminance with a luminance camera.
• Illuminate a translucent screen and measure the surface luminance of the rear side with a
luminance camera
4.Z2 After 4.9 add new sub-clauses 4.Z2 up to 4.Z5 as follows:
4.Z2
The efficacy of an individual lamp shall be calculated from a measurement of luminous
flux and power according to the conditions of Annex B or Annex E as appropriate.
4.Z3
The lamp lumen maintenance factor of an individual lamp shall be calculated from
measurements of its luminous flux made at appropriate times according to the
conditions of Annex B or Annex E as appropriate. Lamp operation between these
measurements shall be as prescribed in Annex C.
4.Z4
The survival of an individual lamp shall be determined by operating lamps under the
conditions prescribed in Annex C until the lamp fails to remain alight or delivers low
light output (in case of doubt, low light output refers to noticeably less than 50 % of
rated light output).
5
---------------------- Page: 7 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
4.Z5
The average mercury content shall be measured in accordance with the CV AAS
method as described in EN 62321-4.
Annex B (normative) Method of measuring electrical and photometrical characteristics
(lamps for operation on 50 Hz or 60 Hz supply frequencies
B.1 General
Replace the following paragraph in B.1
Photometric characteristics shall be measured in accordance with the relevant
recommendations of the CIE (Commission Internationale de l’Éclairage) 84. For
measurement for the centre beam intensity of reflector lamps, IEC/TR 61341 shall be
used.
By
Photometric characteristics shall be measured in accordance with EN 13032-1. For
determination of the centre beam intensity of reflector lamps, EN 61341 shall be used.
Annex E (normative) Method of measuring electrical and photometrical characteristics
on low frequency square wave reference ballast
E.1 Purpose of this annex
Replace the following paragraph in E.1
Photometric characteristics shall be measured in accordance with the relevant
recommendations of the CIE (Commission Internationale de l’Éclairage) 84. For
measurement for the centre beam intensity of reflector lamps, IEC/TR 61341 shall be
used.
By
Photometric characteristics shall be measured in accordance with EN 13032-1. For
determination of the centre beam intensity of reflector lamps, EN 61341 shall be used.
6
---------------------- Page: 8 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Publication Year Title EN/HD Year
- - Light and lighting - Measurement and EN 13032-1 2004
presentation of photometric data of lamps +A1 2012
and luminaires -
Part 1: Measurement and file format
- - Light and lighting - Measurement and EN 13032-4 2015
presentation of photometric data of lamps
and luminaires -
Part 4: LED lamps, modules and
luminaires
IEC 60050-845 - International Electrotechnical Vocabulary - -
- Chapter 845: Lighting
IEC 60061-1 - Lamp caps and holders together with EN 60061-1 1993
gauges for the control of
interchangeability and safety -
Part 1: Lamp caps
IEC 60598-1 - Luminaires - General requirements and EN 60598-1 2015
tests
IEC 60923 - Auxiliaries for lamps - Ballasts for EN 60923 2005
discharge lamps (excluding tubular
fluorescent lamps) - Performance
requirements
IEC 60927 - Auxiliaries for lamps - Starting devices EN 60927 2007
(other than glow starters) - Performance
requirements
IEC/TR 61341 - Method of measurement of centre beam EN 61341 2011
intensity and beam angle(s) of reflector
lamps
IEC 62035 - Discharge lamps (excluding fluorescent EN 62035 2014
lamps) - Safety specifications
IEC 62321-4 Determination of certain substances in EN 62321-4 2014
electrotechnical products -
Part 4: Mercury in polymers, metals
and electronics by CV-AAS, CV-AFS,
ICP-OES and ICP-MS
IEC 62471 - Photobiological safety of lamp and lamp EN 62471 2008
systems
7
---------------------- Page: 9 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
Publication Year Title EN/HD Year
CIE 84 - The measurement of luminous flux - -
CIE 13.3 - Method of Measuring and Specifying - -
Colour Rendering Properties of Light
Sources
8
---------------------- Page: 10 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
Annex ZZA
(informative)
Relationship between this European Standard and the ecodesign requirements
of Commission Regulation (EC) No 245/2009 aimed to be covered
This European Standard has been prepared under a Commission’s standardization request M/495 to
provide one voluntary means of conforming to the ecodesign requirements of Commission Regulation
(EC) No 245/2009 of 18 March 2009 implementing Directive 2009/125/EC of the European Parliament
and of the Council with regard to ecodesign requirements for fluorescent lamps without integrated
ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps,
and repealing Directive 2000/55/EC of the European Parliament and of the Council [2009 OJ L76].
Once this standard is cited in the Official Journal of the European Union under that Regulation,
compliance with the normative clauses of this standard given in Table ZZA.1 confers, within the limits
of the scope of this standard, a presumption of conformity with the corresponding ecodesign
requirements of that Regulation and associated EFTA Regulations.
Table ZZA.1 – Correspondence between this European Standard and Commission Regulation
(EC) No 245/2009 of 18 March 2009 implementing Directive 2009/125/EC of the European
Parliament and of the Council with regard to ecodesign requirements for fluorescent lamps
without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires
able to operate such lamps, and repealing Directive 2000/55/EC of the European Parliament and
of the Council [2009 OJ L76] and Commission’s standardization request M/495
Ecodesign requirements of Clause(s) / sub-clause(s) Remarks / Notes
Regulation No 245/2009
of this EN
[2009 OJ L76]
Annex III, Article 2 Annex B or Annex E as Lamp power
appropriate
Annex III, Article 1.3 Annex B or Annex E as Luminous flux
appropriate
Annex III, Article 1.2, Table 14 Subclause 4.Z4 Lamp survival factor
Annex III, Article 1.2, Table 14 Subclause 4.Z3 Lumen maintenance
Annex II, Article 3(b) Subclause 4.8.4 Chromaticity coordinates
Annex III, Article 1.3 (h) Subclause 4.8.4 Colour rendering index (CRI)
Annex III, Article 1.3 (g) Subclause 4.8.4 Correlated colour temperature
(CCT)
Annex III, Article 2 Annex B or Annex E as Spectral power distribution
appropriate
Annex I, Article 1(d), (h) Annex B or Annex E as specific effective radiant UV
appropriate power
Annex I, Article 1 (i) Subclause 4.4 Caps
Annex III, Article 1.3 (f), Subclause 4.Z5 Mercury content
Annex V, Article 2
WARNING 1 — Presumption of conformity stays valid only as long as a reference to this European
Standard is maintained in the list published in the Official Journal of the European Union. Users of this
standard should consult frequently the latest list published in the Official Journal of the European
Union.
WARNING 2 — Other Union legislation may be applicable to the products falling within the scope of
this standard.
9
---------------------- Page: 11 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
Annex ZZB
(informative)
Relationship between this European Standard and the ecodesign requirements
of Commission Regulation (EU) No 1194/2012 aimed to be covered
This European Standard has been prepared under a Commission’s standardization request M/495 to
provide one voluntary means of conforming to the ecodesign requirements of Commission Regulation
(EU) No 1194/2012 of 12 December 2012 implementing Directive 2009/125/EC of the European
Parliament and of the Council with regard to ecodesign requirements for directional lamps, light
emitting diode lamps and related equipment [2012 OJ L342].
Once this standard is cited in the Official Journal of the European Union under that Regulation,
compliance with the normative clauses of this standard given in Table ZZB.1 confers, within the limits
of the scope of this standard, a presumption of conformity with the corresponding ecodesign
requirements of that Regulation and associated EFTA Regulations.
Table ZZB.1 – Correspondence between this European Standard and Commission Regulation
(EU) No 1194/2012 of 12 December 2012 implementing Directive 2009/125/EC of the European
Parliament and of the Council with regard to ecodesign requirements for directional lamps,
light emitting diode lamps and related equipment [2012 OJ L342] and Commission’s
standardization request M/495
Ecodesign requirements of Clause(s) / sub-clause(s) Remarks / Notes
Regulation No 1194/2012
of this EN
[2012 OJ L342]
Article 2.4, 3.1, Annex I Subclause 4.2 Technical description of special
purpose lamps for eco-design
Annex III, Article 1 Annex B or Annex E as Lamp power
appropriate
Annex III, Article 3.1
Annex III, Article 3.1.1, 3.1.2 (a), Subclause 4.Z1 Useful luminous flux
3.1.3 (c)
Annex III, Article 3.1.2 (i), 3.1.3 Annex B or Annex E as Beam angle
(k) appropriate
Annex III, Table 4, Article 3.1.3 Subclause 4.Z4 Lamp life
Annex III, Table 4, Table 7, Subclause 4.Z3 Lumen maintenance
Article 3.1.3
Not covered in this standard Number of switching cycles
before failure
Annex III, Table 4 Subclause 4.5, Annex A Starting time
Annex III, Table 4 Subclause 4.5, Annex A Warm-up time to 60% ɸ
Annex I Subclause 4.8.4 Chromaticity coordinates
Annex III, article 3.1.3 (h) Subclause 4.8.4 Colour rendering index (CRI)
Annex III, article 3.1.1, 3.1.2 (c) Subclause 4.8.4 Correlated colour temperature
(CCT)
Not covered in this standard Power factor
(only for lamps with integrated control
gear)
Annex III, article 3.1.2 (h) Subclause 4.3 (Data sheets Lamp dimensions
Clause 6)
Annex III, article 3.1.3 (m) Annex B or Annex E as Spectral power distribution
10
---------------------- Page: 12 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
Ecodesign requirements of Clause(s) / sub-clause(s) Remarks / Notes
Regulation No 1194/2012
of this EN
[2012 OJ L342]
appropriate
Annex III, article 3.1.2 (n), (o) Subclause 4.Z5 Mercury content
Not covered in this standard Dimmability
Not covered in this standard Lamp type (MR11 GU4 etc.)
Annex III, article 3.1.3 (j) Annex B or Annex E as Peak intensity in candela
appropriate
WARNING 1 — Presumption of conformity stays valid only as long as a reference to this European
Standard is maintained in the list published in the Official Journal of the European Union. Users of this
standard should consult frequently the latest list published in the Official Journal of the European
Union.
WARNING 2 — Other Union legislation may be applicable to the products falling within the scope of
this standard.
11
---------------------- Page: 13 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
Annex ZZC
(informative)
Relationship between this European Standard and the energy labelling
requirements of Commission Delegated Regulation (EU) No 874/2012 aimed to
be covered
This European standard has been prepared under a Commission’s standardisation request M/495 to
provide one voluntary means of conforming to the energy labelling requirements of Commission
Delegated Regulation (EU) No 874/2012 of 12 July 2012 supplementing Directive 2010/30/EU of the
European Parliament and of the Council with regard to energy labelling of electrical lamps and
luminaires [2012 OJ L258].
Once this standard is cited in the Official Journal of the European Union under that Regulation,
compliance with the normative clauses of this standard given in Table ZZC.1 confers, within the limits
of the scope of this standard, a presumption of conformity with the corresponding energy labelling
requirements of that Regulation and associated EFTA Regulations.
Table ZZC.1 – Correspondence between this European Standard and Commission Delegated
Regulation (EU) No 874/2012 of 12 July 2012 supplementing Directive 2010/30/EU of the
European Parliament and of the Council with regard to energy labelling of electrical lamps and
luminaires [2012 OJ L258] and Commission’s standardisation request M/495
Energy labelling requirements of Clause(s) / sub-clause(s) Remarks / Notes
Regulation No 874/2012
of this EN
[2012 OJ L258]
Article 1 Annex B or Annex E as Applicable parameter according
appropriate to Article 1: luminous flux
Annex VII Annex B or Annex E as Lamp power
appropriate
Annex VII Annex B or Annex E as Luminous flux (non-directional
appropriate only)
Annex VII Subclause 4.Z1 Useful luminous flux (directional
only)
Annex VII Annex B or Annex E as Beam angle
appropriate
WARNING 1 — Presumption of conformity stays valid only as long as a reference to this European
Standard is maintained in the list published in the Official Journal of the European Union. Users of this
standard should consult frequently the latest list published in the Official Journal of the European
Union.
WARNING 2 — Other Union legislation may be applicable to the products falling within the scope of
this standard.
12
---------------------- Page: 14 ----------------------
SIST EN 61167:2019
EN 61167:2018 (E)
Bibliography
Add the following notes for the standards indicated:
IEC 60081 NOTE Harmonized as EN 60081.
IEC 60188 NOTE Harmonized as EN 60188.
IEC 60357:2002 NOTE Harmonized as EN 60357:2003 (modified).
IEC 60682 NOTE Harmonized as EN 60682.
IEC 61231 NOTE Harmonized as EN 61231.
Add the following documents:
COMMISSION REGULATION (EC) No 245/2009 of 18 March 2009 implementing
Directive 2005/32/EC of the European Parliament and of the Council with regard to
ecodesign requirements for fluorescent lamps without integrated ballast, for high
intensity discharge lamps, and for ballasts and luminaires able to operate such lamps,
and repealing Directive 2000/55/EC of the European Parliament and of the Council
COMMISSION REGULATION (EU) No 874/2012 of 12 July 2012 supplementing
Directive 2010/30/EU of the European Parliament and of the Council with regard to
energy labelling of electrical lamps and luminaires
COMMISSION REGULATION (EU) No 1194/2012 of 12 December 2012
implementing Directive 2009/125/EC of the European Parliament and of the Council
with regard to ecodesign requirements for directional lamps, light emitting diode lamps
and related equipment
13
---------------------- Page: 15 ----------------------
SIST EN 61167:2019
---------------------- Page: 16 ----------------------
SIST EN 61167:2019
IEC 61167
®
Edition 4.0 2018-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Metal halide lamps – Performance specification
Lampes aux halogénures métalliques – Spécifications de performances
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.140.30 ISBN 978-2-8322-5649-7
Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 17 ----------------------
SIST EN 61167:2019
– 2 – IEC 61167:2018 © IEC 2018
CONTENTS
FOREWORD . 6
INTRODUCTION . 8
1 Scope . 10
2 Normative references . 10
3 Terms and definitions . 11
4 Lamp requirements . 13
4.1 General . 13
4.2 Marking . 13
4.2.1 Colour appearance . 13
4.2.2 Lamps for operation on high pressure sodium controlgear . 13
4.3 Dimensions . 14
4.4 Caps . 14
4.5 Starting and warm-up characteristics . 14
4.5.1 Lamps that may operate on electromagnetic ballasts . 14
4.5.2 Lamps suitable for low frequency square wave ballasts only . 14
4.6 Electrical characteristics . 14
4.7 Photometric characteristics . 14
4.8 Colour characteristics . 14
4.8.1 Lamps with non-standardised chromaticity co-ordinates . 14
4.8.2 Lamps with standardised chromaticity co-ordinates . 15
4.8.3 Colour rendering index . 15
4.8.4 Requirements and test conditions . 15
4.9 Lumen maintenance and life . 15
5 Information for ballast, ignitor and luminaire design . 15
6 Data sheets . 15
6.1 General principles of numbering sheets . 15
6.2 Lists of data sheets . 15
6.2.1 List of diagrammatic lamp data sheets .
...
Questions, Comments and Discussion