SIST EN 27740:2000/AC:2000
(Amendment)Instruments for surgery, scalpels with detachable blades, fitting dimensions (ISO 7740:1985)
Instruments for surgery, scalpels with detachable blades, fitting dimensions (ISO 7740:1985)
Chirurgische Instrumente, Skalpelle mit auswechselbaren Klingen, Paßmaße (ISO 7740:1985)
Instruments chirurgicaux, bistouris a lames détachables, dimensions d'assemblage (ISO 7740:1985)
Kirurški instrumenti, skalpeli s snemnimi rezili, mere nastavkov (ISO 7740:1985)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 27740:2000/AC:2000
01-januar-2000
Kirurški instrumenti, skalpeli s snemnimi rezili, mere nastavkov (ISO 7740:1985)
Instruments for surgery, scalpels with detachable blades, fitting dimensions (ISO
7740:1985)
Chirurgische Instrumente, Skalpelle mit auswechselbaren Klingen, Paßmaße (ISO
7740:1985)
Instruments chirurgicaux, bistouris a lames détachables
...
This May Also Interest You
This document specifies the general requirements for instruments to be used in association with nonactive
surgical implants. These requirements apply to instruments when they are manufactured and
when they are supplied after refurbishment.
NOTE In this document, unless otherwise specified, the term “instrument” refers to an instrument for use in
association with non-active surgical implants.
This document also applies to instruments which can be connected to power-driven systems, but it
does not apply to the power-driven systems themselves.
With regard to safety, this document gives the requirements for intended performance, design
attributes, materials, design evaluation, manufacture, sterilization, packaging, and information
supplied by the instrument manufacturer, hereafter referred to as the manufacturer.
This document is not applicable to instruments associated with dental implants, transendodontic and
transradicular implants and ophthalmic implants.
- Standard23 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft19 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of ISO 7153 specifies metals commonly used to manufacture various types of standard
surgical instruments, including but not limited to those used in general surgery, orthopaedics and
dentistry.
While this part of ISO 7153 is not intended for surgical instruments used in special applications, such
as implantology and minimally invasive surgery, parts of it might be applicable to those instruments.
NOTE When selecting the grade of steel and the shape, dimensions and delivery conditions of the raw
material for manufacturing surgical instruments, it is necessary to take into account factors, such as the design
of the instrument or the production facilities of the manufacturer, that are not covered by this part of ISO 7153.
For this reason, it is not intended, nor is it possible, for the information given in this part of ISO 7153 to remove
the decision-making responsibility from the instrument manufacturer for selecting an appropriate raw product
with suitable properties; nor is it intended to preclude the use of other types of steel in the manufacture of
instruments, such as the use of carbon steel for cutting instruments. International Standards for surgical
instruments, when published, can be observed when making this decision as they may contain additional or new
information to be taken into account when selecting appropriate steel grades.
- Standard20 pagesEnglish languagesale 10% offe-Library read for×1 day
This International Standard is applicable to disposable and reusable, as well as woven and non-woven
materials used as surgical drapes and other patient-protective covers which claim to be laser-resistant.
The purpose of this International Standard is to provide a standardized method for testing and
classifying surgical drapes and other patient-protective covers with respect to laser-induced hazards.
An appropriate classification system is given. It is not the purpose of this International Standard to
serve as a general fire safety specification, and as such, this International Standard does not cover other
sources of ignition.
All materials reflect portions of the beam and it is necessary for the user to decide whether specular
reflectance can be a hazard. This measurement, however, is not covered in this International Standard.
The test procedure can be used to assess the laser induced flammability properties of non-laserresistant
items
NOTE Users of products tested by this method are cautioned that the laser resistance of a surgical drape
and/or patient-protective cover will be wavelength sensitive and that a surgical drape and/or patient-protective
cover are better tested at the wavelength for which it is intended to be used. If tested using other wavelengths, it
is necessary to explicitly state the power settings and modes of delivery.
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
Describes test methods to determine the resistance of stainless steel surgical and dental hand instruments against autoclaving, corrosion and thermal exposure.
- Standard7 pagesEnglish languagesale 10% offe-Library read for×1 day
This International Standard lays down the dimensions of two sizes of fitting features for detachable scalpel blades and the handles with which they are used.
- Standard5 pagesEnglish languagesale 10% offe-Library read for×1 day
2020-01-20: Originator of XML version: NEN (on behalf of NEN, ASI, DS, SFS, SIS, SN)
- Amendment4 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of SURGICAL
LUMINAIRES and LUMINAIRES FOR DIAGNOSIS, hereafter referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the
case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
This particular standard does not apply to
– headlights;
– endoscopes, laparoscopes and their light sources, which are covered by IEC 60601-2-18;
– luminaires used in dentistry, which are covered by ISO 9680;
– luminaires for general purposes, which are covered by IEC 60598-2-1 and IEC 60598-2-4;
– luminaires dedicated to therapeutic purposes;
– special purpose lights with different conditions of use such as light sources intended solely
for decontamination of air and surfaces, UV lights for dermatological diagnosis, slit lamps
for ophthalmology, lights for surgical microscopes and lights for surgical navigation systems;
– lights connected to surgical instruments, such as luminous retractors;
– luminaires for emergency lighting, which are covered by IEC 60598-2-22.
NOTE See also 4.2 of the general standard.
SURGICAL LUMINAIRES and LUMINAIRES FOR DIAGNOSIS are medical devices and not general
lighting equipment.
- Standard63 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 80601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
ROBOTICALLY ASSISTED SURGICAL EQUIPMENT (RASE) and ROBOTICALLY ASSISTED SURGICAL
SYSTEMS (RASS), hereafter referred to as ME EQUIPMENT and ME SYSTEMS together with their
INTERACTION CONDITIONS and INTERFACE CONDITIONS. If a clause or subclause is specifically
intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of
that clause or subclause will say so. If that is not the case, the clause or subclause applies
both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
If RASE or RASS, or its ACCESSORIES fall within scope of another particular standard, then the
particular standard applies in addition to this standard.
EXAMPLES IEC 60601-2-2[3] for HF SURGICAL EQUIPMENT; IEC 60601-2-18[4] for ENDOSCOPIC EQUIPMENT;
IEC 60601-2-22[5] for laser equipment; IEC 60601-2-37[6] for ultrasound equipment; IEC 60601-2-46[7] for
operating tables, etc
- Standard55 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the general requirements for instruments to be used in association with nonactive
surgical implants. These requirements apply to instruments when they are manufactured and
when they are supplied after refurbishment.
NOTE In this document, unless otherwise specified, the term “instrument” refers to an instrument for use in
association with non-active surgical implants.
This document also applies to instruments which can be connected to power-driven systems, but it
does not apply to the power-driven systems themselves.
With regard to safety, this document gives the requirements for intended performance, design
attributes, materials, design evaluation, manufacture, sterilization, packaging, and information
supplied by the instrument manufacturer, hereafter referred to as the manufacturer.
This document is not applicable to instruments associated with dental implants, transendodontic and
transradicular implants and ophthalmic implants.
- Standard23 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft19 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HF
SURGICAL EQUIPMENT and HF SURGICAL ACCESSORIES as defined in 201.3.224 and 201.3.223.
HF SURGICAL EQUIPMENT having a RATED OUTPUT POWER not exceeding 50 W (for example for
micro-COAGULATION, or for use in dentistry or ophthalmology) is exempt from certain of the
requirements of this particular standard. These exemptions are indicated in the relevant
requirements.
- Standard93 pagesEnglish languagesale 10% offe-Library read for×1 day