This part of IEC 60598 specifies requirements for fixed general purpose luminaires for use
with electric light sources on supply voltages not exceeding 1 000 V.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part 1 of IEC 60598 specifies general requirements for luminaires, incorporating electric
light sources for operation from supply voltages up to 1 000 V. The requirements and related
tests of this document cover: classification, marking, mechanical construction, electrical
construction and photobiological safety.
Each section of this Part 1 is read in conjunction with this Section 0 and with other relevant
sections to which reference is made.
Each part of IEC 60598-2 details requirements for a particular type of luminaire or group of
luminaires on supply voltages not exceeding 1 000 V. These parts are published separately
for ease of revision and additional sections will be added as and when a need for them is
recognized.
The presentation of photometric data for luminaires is under consideration by the International
Commission on Illumination (CIE) and is not, therefore, included in this Part 1.
Requirements are included in this Part 1 for luminaires incorporating ignitors with nominal
peak values of the voltage pulse not exceeding those of Table 11.2. The requirements apply
to luminaires with ignitors built into ballasts and to luminaires with ignitors separate from
ballasts. For luminaires with ignitors built into lamps, the requirements are under
consideration.
Requirements for semi-luminaires are included in this Part 1.
In general, this Part 1 covers safety requirements for luminaires. The object of this Part 1 is to
provide a set of requirements and tests which are considered to be generally applicable to
most types of luminaires and which can be called up as required by the detail specifications of
IEC 60598-2. This Part 1 is thus not regarded as a specification in itself for any type of
luminaire, and its provisions apply only to particular types of luminaires to the extent
determined by the appropriate part of IEC 60598-2.
The parts of IEC 60598-2, in making reference to any of the sections of Part 1, specify the
extent to which that section is applicable and the order in which the tests are performed; they
also include additional requirements as necessary.
The order in which the sections of Part 1 are numbered has no particular significance as the
order in which their provisions apply is determined for each type of luminaire or group of
luminaires by the appropriate part of IEC 60598-2. All parts of IEC 60598-2 are self-contained
and therefore do not contain references to other parts of IEC 60598-2.
Where the requirements of any of the sections of Part 1 are referred to in the parts of
IEC 60598-2 by the phrase "The requirements of section... of IEC 60598-1 apply", this phrase
is interpreted as meaning that all the requirements of that section of Part 1 apply except those
which are clearly inapplicable to the particular type of luminaire covered by that part of
IEC 60598-2.
For explosion proof luminaires, as covered by IEC 60079, the requirements of IEC 60598
(selecting the appropriate parts 2) are applied in addition to the requirements of IEC 60079. In
the event of any conflict between IEC 60598 and IEC 60079, the requirements of IEC 60079
take priority.
Improvements in safety to take into account the state of the art technology are incorporated in
the standards with revisions and amendments on an ongoing basis. Regional standardization
bodies can include statements in their derived standards to cover products which have
complied with the previous document as shown by the manufacturer or standardization body.
The statements may require that for such products, the previous standard may continue to
apply to production until a defined date after which the new standard shall apply.

  • Standard
    239 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60598 specifies requirements for extra-low-voltage lighting systems for ELV
light sources, intended for ordinary interior use on supply voltages not exceeding 1 000 V. The
luminaires, being connected in parallel, are supplied via freely suspended continuous
supporting conductors or profiles, the current in the ELV part of the system not exceeding 25 A.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-1:2020 is available as IEC 60598-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source;
- Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0;
- Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984;
- Addition of Subclause 3.3.25, UV protection of cable;
- Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493);
- Revision of the requirements for functional earth and protective earth;
- Addition of Clause 4.35, Protection against fast rotating parts;
- Revision of Clause 3.2, Rated voltage marking;
- Revision of Subclause 5.2.10, Cord anchorage;
- Revision of Annex G for touch current and protective conductor current test set-up;
- Addition of requirements for constant light output function and programmable current output;
- Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage;
- Introduction of PELV;
- Introduction of Ethernet power supply connection for luminaires (PoE);
- Section 9, Introduction of IPX9;
- Addition of Subclause 3.3.26 for wall mounted luminaires;
- Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C;
- Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits;
- Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019;
- Revision of Subclause 10.2.2, alternative DC electric strength test;
- Revision of Annex D for recessed luminaires;
- Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands;
- Revision of use of bridging capacitors in luminaires;
- Revision of electrical connection to class III plugs.

  • Standard
    229 pages
    English language
    sale 15% off

IEC 60598-2-23:2020 specifies requirements for extra-low-voltage lighting systems for ELV light sources, intended for ordinary interior use on supply voltages not exceeding 1 000 V. The luminaires, being connected in parallel, are supplied via freely suspended continuous supporting conductors or profiles, the current in the ELV part of the system not exceeding 25 A.
This second edition cancels and replaces the first edition published in 1996 and Amendment 1:2000. This edition constitutes a technical revision.
This edition includes the following technical changes with respect to the previous edition (there are no major technical changes, see Annex A):
a) The title has been modified to allow the inclusion of other light sources;
b) The scope has been updated to be aligned with the other parts of the IEC 60598-2 series and to include other light sources;
c) Normative references and the reference to transformer and controlgear standards have been updated;
d) The short circuit test (23.7.6.1 and 23.7.6.2) was removed and reference is now made to the same test in Part 1.

  • Standard
    25 pages
    English and French language
    sale 15% off

NEXT ACTION: CCMC to finalize publication
2019-11-13 PeC: BT approved the publication
2019-03-21 - GEM - TC discussed with consultant (C. Maes) at meeting (MArch 2019) - comments accepted - Annex ZA to be dated. Project has normative refverence to PR=63474, which creates a dependency.
2019-02-28 PC: to be flagged for LVD citation when ready
2018-12-17 PC: "Lack of compliance" for LVD, undated references in the Annex ZA and some points in the standards should be clarified
2017-11-21 - Negative assessment is received during CDV stage. Consultant assessment request is missing for FDIS.

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: CCMC to finalize publication
2019-11-13 PeC: BT approved the publication
2019-03-21 - GEM - TC discussed with consultant (C. Maes) at meeting (MArch 2019) - comments accepted - Annex ZA to be dated. Project has normative refverence to PR=63474, which creates a dependency.
2019-02-28 PC: to be flagged for LVD citation when ready
2018-12-17 PC: "Lack of compliance" for LVD, undated references in the Annex ZA and some points in the standards should be clarified
2017-11-21 - Negative assessment is received during CDV stage. Consultant assessment request is missing for FDIS.

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: PUBLICATION EXPECTED BY 2020-04

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-1:2020 specifies requirements for fixed general purpose luminaires for use with electric light sources on supply voltages not exceeding 1 000 V.
This second edition cancels and replaces the first edition published in 1979 and Amendment 1:1987. This edition constitutes a technical revision.
This edition includes the following technical changes with respect to the previous edition (there are no major technical changes, see Annex A):
a) the scope has been modified to be in line with Part 1 to include all electric light sources,
b) references to Part 1 have been updated.

  • Standard
    13 pages
    English and French language
    sale 15% off

IEC 62990-1:2019 specifies general requirements for design, function and performance, and describes the test methods that apply to portable, transportable, and fixed equipment for the detection and concentration measurement of toxic gases and vapours in workplace atmospheres and other industrial and commercial applications.
This document is applicable to continuously sensing equipment whose primary purpose is to provide an indication, alarm and/or other output function the purpose of which is to indicate the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate automatic or manual protective action(s). It is applicable to equipment in which the sensor generates an electrical signal when gas is present.
This document applies to two types of equipment:
• Type HM (Health Monitoring) ‘occupational exposure’ equipment:
For occupational exposure measurement, the performance requirements are focused on uncertainty of measurement of gas concentrations in the region of Occupational Exposure Limit Values (OELV). The upper limit of measurement will be defined by the manufacturer in accordance with 4.2.1.
• Type SM (Safety Monitoring) ‘general gas detection’ equipment:
For general gas detection applications (e.g. safety warning, leak detection), the performance requirements are focused on alarm signalling. The upper limit of measurement will be defined by the manufacturer according to the intended use of the equipment.
In general, the requirements for accuracy will be higher for Type HM equipment than for Type SM equipment. The same equipment may meet the requirements of both Type HM and Type SM.
For equipment used for sensing the presence of multiple gases this document applies only to the detection of toxic gas or vapour.
This document is not applicable to equipment:
- with samplers and concentrators such as sorbents or paper tape having an irreversible indication;
- used for the measurement of gases and vapours related to the risk of explosion;
- used for the measurement of oxygen;
- used only in laboratories for analysis or measurement;
- used only for process measurement purposes;
- used in the domestic environment;
- used in environmental air pollution monitoring;
- used for open-path (line of sight) area gas measurement;
- used for ventilation control in car parks or tunnels.
The contents of the corrigendum of December 2019 have been included in this copy.

  • Standard
    124 pages
    English and French language
    sale 15% off

This European Standard defines a measure for the spectral quality of LED luminaires in terms of the ratio of the amount of visual light emitted by the luminaire versus the amount effective for charging photoluminescent products contained in that spectrum.
Fulfilment of this European Standard by a LED luminaire will ensure general compatibility of the luminaire with photoluminescent marking systems.
This European Standard alone does not provide any means of compliance to fulfil any airworthiness requirements.
For a specific aircraft installation, the spectral power distribution and illuminance at the photoluminescent marking systems are relevant.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2018-09-14 PeC: Cited under the LVD in C 326/02
20180129: BT decision D139/C142 for implementation dates

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60598-2 specifies requirements for portable general purpose luminaires for
indoor and/or outdoor use (e.g. garden use), other than handlamps, designed to be used with
or incorporating electrical light sources on supply voltages not exceeding 250 V.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60598-2 specifies requirements for stage, television, film and photographic
studio luminaires (including spot and floodlighting projectors) for use outdoors and indoors, with
electric light sources on supply voltages not exceeding 1 000 V.
NOTE A hanger (stirrup) is a part of the luminaire. Supporting devices such as tripods, telescopic booms and
suspensions are not parts of the luminaire. Where applicable, ballasts are built into or mounted separately from the
luminaires.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 60598-2-4:2017 is available as IEC 60598-2-4:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60598-2-4:2017 specifies requirements for portable general purpose luminaires for indoor and/or outdoor use (e.g. garden use), other than handlamps, designed to be used with or incorporating electrical light sources on supply voltages not exceeding 250 V. This third edition cancels and replaces the second edition published in 1997. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - alignment with IEC 60598-1; - modification of the scope, classification and requirements to cover portable luminaires for both indoor and outdoor applications, by introducing the requirements already listed in IEC 60598-2-7; NOTE  In this edition of IEC 60598-2-4 all requirements listed in IEC 60598-2-7 have been incorporated. As a consequence, IEC 60598-2-7 will be withdrawn after publication of this standard. - modification of the scope to cover all electrical light sources (it was previously limited to tungsten filament, tubular fluorescent and other discharge lamps); - introduction of the symbol for luminaires which are other than ordinary, but suitable for indoor applications only (e.g. luminaire using PVC cable); - modification in the detail of test to clarify that the stability test on an inclined plane (see 4.7.3) shall be carried out with the light source(s) in place; - modification of the minimum degree of protection against dust and moisture for portable luminaires for outdoor use from IPX3 to IPX4 (see 4.5.2); as a consequence, the requirements for cable entry position, as given in IEC 60598-2-7:1982, 7.6.3 were deleted as they are covered by IPX4; - modification of the requirements for the acceptance criteria of plug and socket outlet; - modification of the IP test requiring the most unfavourable of the overturned positions to cover all classes (and not only class II luminaires as in 7.13.1 of IEC 60598-2-7:1982).

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-17:2017 specifies requirements for stage, television, film and photographic studio luminaires (including spot and floodlighting projectors) for use outdoors and indoors, with electric light sources on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published in 1984 and Amendement 2:1990. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) extension of the applicable scope from light source to electric light source and replacement of "tungsten filament, tubular fluorescent and other discharge lamps" with "electric light source" in 17.1. b) consideration of the fact that there are many LED luminaires with non-replaceable light source, and light source without a glass bulb, or with low operation temperature: the applicable scope of relevant clauses therefore only applies to replaceable light source luminaires with a glass bulb lamp, or with high surface temperature.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2017-05-02: D156/C084 - Ratified standards not being made available.
2017-03-28: BT decided to have this standard published (D156/C084)
2016-11-23: includes common modifications from 63999

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-17:2017 specifies requirements for stage, television, film and photographic studio luminaires (including spot and floodlighting projectors) for use outdoors and indoors, with electric light sources on supply voltages not exceeding 1 000 V.
This second edition cancels and replaces the first edition published in 1984 and Amendement 2:1990. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) extension of the applicable scope from light source to electric light source and replacement of "tungsten filament, tubular fluorescent and other discharge lamps" with "electric light source" in 17.1.
b) consideration of the fact that there are many LED luminaires with non-replaceable light source, and light source without a glass bulb, or with low operation temperature: the applicable scope of relevant clauses therefore only applies to replaceable light source luminaires with a glass bulb lamp, or with high surface temperature.

  • Standard
    17 pages
    English and French language
    sale 15% off

IEC corrigendum

  • Corrigendum
    4 pages
    French language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-4:2017 is available as IEC 60598-2-4:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60598-2-4:2017 specifies requirements for portable general purpose luminaires for indoor and/or outdoor use (e.g. garden use), other than handlamps, designed to be used with or incorporating electrical light sources on supply voltages not exceeding 250 V.
This third edition cancels and replaces the second edition published in 1997. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- alignment with IEC 60598-1;
- modification of the scope, classification and requirements to cover portable luminaires for both indoor and outdoor applications, by introducing the requirements already listed in IEC 60598-2-7;
NOTE In this edition of IEC 60598-2-4 all requirements listed in IEC 60598-2-7 have been incorporated. As a consequence, IEC 60598-2-7 will be withdrawn after publication of this standard.
- modification of the scope to cover all electrical light sources (it was previously limited to tungsten filament, tubular fluorescent and other discharge lamps);
- introduction of the symbol for luminaires which are other than ordinary, but suitable for indoor applications only (e.g. luminaire using PVC cable);
- modification in the detail of test to clarify that the stability test on an inclined plane (see 4.7.3) shall be carried out with the light source(s) in place;
- modification of the minimum degree of protection against dust and moisture for portable luminaires for outdoor use from IPX3 to IPX4 (see 4.5.2); as a consequence, the requirements for cable entry position, as given in IEC 60598-2-7:1982, 7.6.3 were deleted as they are covered by IPX4;
- modification of the requirements for the acceptance criteria of plug and socket outlet;
- modification of the IP test requiring the most unfavourable of the overturned positions to cover all classes (and not only class II luminaires as in 7.13.1 of IEC 60598-2-7:1982).

  • Standard
    21 pages
    English and French language
    sale 15% off

2017-05-02: D156/C084 - Ratified standards not being made available.
2017-03-28: BT decided to have this standard published (D156/C084)
2016-11-23: includes common modifications from 63999

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-10-02: EC formal rejection from citation LVD 2014/35/EU
2019-09-26 PeC: cannot be cited for LVD, Annex ZZ is not in the right format
2017-05-02: D156/C084 - Ratified standards not being made available.

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-10-02: EC formal rejection from citation LVD 2014/35/EU
2019-09-26 PeC: cannot be cited for LVD, Annex ZZ is not in the right format
2017-05-02: D156/C084 - Ratified standards not being made available.

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC corrigendum

  • Corrigendum
    3 pages
    English and French language
    sale 10% off
    e-Library read for
    1 day

This Part 2 of IEC 60598 specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V, for indoor or outdoor use, e.g. in gardens, yards, carriageways, parking lots, cycleways, footways, pedestrian areas, swimming pools areas outside zones for SELV, nurseries and similar applications.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61204-3:2016 is available as IEC 61204-3:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61204-3:2016 specifies the electromagnetic compatibility (EMC) requirements for switch mode power supply (SMPS) units supplied by source voltages up to 1 000 V AC or 1 500 V DC providing AC and/or DC output(s), except inverter output(s) establishing AC mains. This edition includes the following significant technical changes with respect to the previous edition:
a) the title has been changed by deleting the wording "DC output-" from the title and adding "switch mode" in the title;
b) changes in the scope: 1.1.1 Equipment covered by this document;
c) update of the normative references to the latest editions or dated references;
d) change of wording or/and notes regarding the requirements of CENELEC Guide 24 and IEC Guide 107;
e) revision of the emission limits to align with the latest editions of the applicable normative references;
f) revision of the immunity requirements to align with the latest editions of the applicable normative references;
g) correction of typographical errors.

  • Standard
    82 pages
    English and French language
    sale 15% off

This Part 2 of IEC 60598 specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V, for indoor or outdoor use, e.g. in gardens, yards, carriageways, parking lots, cycleways, footways, pedestrian areas, swimming pools areas outside zones for SELV, nurseries and similar applications.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62722 specifies the performance requirements for LED luminaires, together with the test methods and conditions, required to show compliance with this standard. It applies to LED luminaires for general lighting purposes.
The following types of LED luminaires are distinguished.
– Type A – Luminaires using LED modules where compliance with IEC 627171 has been proven.
– Type B – Luminaires using LED modules where compliance with IEC 627171 has not been proven.
– Type C – Luminaires using a LED lamp and covered in IEC 62722-1.
The requirements of this standard only relate to type testing.
This standard does not cover Type C luminaires.
This standard does not cover LED luminaires that intentionally produce coloured light, neither does it cover luminaires using OLEDs (organic LEDs).
These performance requirements are additional to the requirements in IEC 62722-1,
Clauses 1 to 9, except where in this Part 2-1 alternative methods of measurement or limits are specified.
As this standard has been simultaneously developed and edited with the standard for LED modules, where appropriate the compliance of the LED modules to the provisions of IEC 62717 may be transferred to the whole luminaire.
Life time of LED luminaires is in most cases much longer than the practical test times. Consequently, verification of manufacturer’s life time claims cannot be made in a sufficiently confident way. For that reason the acceptance or rejection of a manufacturer’s life time claim, past 25 % of rated life (with a maximum of 6 000 h), is out of the scope of this standard.
Instead of life time validation, this standard has opted for lumen maintenance categories at a defined finite test time. Therefore, the category number does not imply a prediction of achievable life time. The categories are lumen-depreciation character categories showing behaviour in agreement with manufacturer’s information which is provided before the test is started.
In order to validate a life time claim, an extrapolation of test data is needed. A general method of projecting measurement data beyond limited test time is under consideration.
For explanation of recommended life time metrics see IEC 62717, Annex C.
It may be expected that LED luminaires which comply with this standard will start and operate satisfactorily at voltages between 92 % and 106 % of rated supply voltage and at an ambient air temperature within the declared range of the manufacturer.
Evaluation of LOR (light output ratio) for LED luminaire is under consideration.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2018-09-26 PeC: not to be offered for citation under the LVD, includes modifications
IEC corrigendum

  • Corrigendum
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62722-2-1:2014 specifies the performance requirements for LED luminaires, together with the test methods and conditions, required to show compliance with this standard. It applies to LED luminaires for general lighting purposes. This first edition of IEC 62722-2-1 cancels and replaces IEC PAS 62722-2-1. published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the Publicly Available Specification. a) The testing time is aligned with IEC 62717 and the option of 2 000 h is removed. Products containing modules not in compliance with IEC 62717 are now tested to 6 000 h. b) Testing sample sizes have been modified to give valid statistical data. c) The temperature reduction of 10 °C for street lanterns and floodlights has been removed. d) Life definitions have been updated and aligned with IEC 62717.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC corrigendum

  • Corrigendum
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60598 specifies requirements for floodlights for use with electrical light
sources on supply voltages not exceeding 1 000 V.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC corrigendum

  • Corrigendum
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62722 covers specific performance and environmental requirements for
luminaires, incorporating electric light sources for operation from supply voltages up to
1 000 V. Unless otherwise detailed, performance data covered under the scope of this
standard are for the luminaires in a condition representative of new manufacture, with any
specified initial aging procedures completed.
IEC 62722-1 covers requirements for luminaires to support energy efficient use and
responsible environmental management to the end of life. The object of this Part 1 is to
provide a set of requirements which are considered to be generally applicable to most types
of luminaires. Where additional performance requirements for specific types of light source
are relevant, these are specified in the IEC 62722-2 series. The IEC 62722-2 series may also
cover a wider scope of performance aspects appropriate to the particular light source
technology.
NOTE The structure of these performance standards also allows for the possibility of Part 3 standards to be
introduced in the future should standardisation of performance criteria linked to specific luminaire applications be
determined as necessary (e.g. floodlighting, street lighting, etc.).
It is the intention that the requirements of this Part 1 are to be met by the provision of
information and data provided by the luminaire manufacturer (or responsible vendor).
Conformity is considered to be met by the provision of the requested information. Any
verification of data is to be conducted by the measurement requirements of this standard.
Semi-luminaires are not covered under the scope of this standard.
For some types of luminaire (e.g. decorative/household) the provision of performance data
under the scope of this standard may not be appropriate.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day