SIST EN ISO 18777:2005
(Main)Transportable liquid oxygen systems for medical use - Particular requirements (ISO 18777:2005)
Transportable liquid oxygen systems for medical use - Particular requirements (ISO 18777:2005)
Registered under VA/CEN upon receipt of document for processing to // DIS/CEN Enq and further to confirmation from ISO/CS (NT/030417).
Flüssigsauerstoffsysteme für medizinische Anwendungen - Besondere Anforderungen (ISO 18777:2005)
Systemes transportables d'oxygene liquide a usage médical - Exigences particulieres (ISO 18777:2005)
Prenosni sistemi tekočega kisika za medicinsko uporabo – Posebne zahteve (ISO 18777:2005)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN ISO 18777:2005
01-junij-2005
3UHQRVQLVLVWHPLWHNRþHJDNLVLND]DPHGLFLQVNRXSRUDER±3RVHEQH]DKWHYH,62
Transportable liquid oxygen systems for medical use - Particular requirements (ISO
18777:2005)
Flüssigsauerstoffsysteme für medizinische Anwendungen - Besondere Anforderungen
(ISO 18777:2005)
Systemes transportables d'oxygene liquide a usage médical - Exigences particulieres
(ISO 18777:2005)
Ta slovenski standard je istoveten z: EN ISO 18777:2005
ICS:
11.040.10 Anestezijska, respiratorna in Anaesthetic, respiratory and
reanimacijska oprema reanimation equipment
SIST EN ISO 18777:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN ISO 18777:2005
---------------------- Page: 2 ----------------------
SIST EN ISO 18777:2005
EUROPEAN STANDARD
EN ISO 18777
NORME EUROPÉENNE
EUROPÄISCHE NORM
February 2005
ICS 11.040.99
English version
Transportable liquid oxygen systems for medical use - Particular
requirements (ISO 18777:2005)
Systèmes transportables d'oxygène liquide à usage Flüssigsauerstoffsysteme für medizinische Anwendungen -
médical - Exigences particulières (ISO 18777:2005) Besondere Anforderungen (ISO 18777:2005)
This European Standard was approved by CEN on 28 January 2005.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2005 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 18777:2005: E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN ISO 18777:2005
EN ISO 18777:2005 (E)
Foreword
This document (EN ISO 18777:2005) has been prepared by Technical Committee CEN/TC 215 "Respiratory
and anaesthetic equipment", the secretariat of which is held by BSI, in collaboration with Technical
Committee ISO/TC 121 "Anaesthetic and respiratory equipment”.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by August 2005, and conflicting national standards shall be withdrawn
at the latest by August 2005.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland
and United Kingdom.
2
---------------------- Page: 4 ----------------------
SIST EN ISO 18777:2005
EN ISO 18777:2005 (E)
ANNEX ZA
(informative)
Relationship between this International Standard and the Essential
Requirements of EU Directive 93/42 EEC Medical devices
This International Standard has been prepared under a mandate given to CEN by the European Commission
and the European Free Trade Association to provide one means of conforming to Essential Requirements of
the New Approach Directive 93/42 EEC Medical devices.
Once this standard is cited in the Official Journal of the European Communities under that Directive and has
been implemented as a national standard in at least one Member State, compliance with the normative
clauses of this standard given in Table ZA.1 confers, within the limits of the scope of this standard, a
presumption of conformity with the corresponding Essential Requirements of that Directive and associated
EFTA regulations.
WARNING: Other requirements and other EU Directives may be applicable to the product(s) falling within
the scope of this standard.
Table ZA.1 — Correspondence between this International Standard and Directive 93/42/EEC
Medical devices
Clause(s)/Subclause(s) of this Essential Requirements (Ers) Qualifying remarks/Notes
International Standard of EU Directive 93/42/EEC
4 All
5 All
6 13, 13.2
6.1 13.1, 13.3, 13.4, 13.5
6.3 10.2, 10.3, 12.8, 12.9
6.8 13.1, 13.3, 13.4, 13.6
6.101 12.9
7 12.6
8 12.6
9 12.6
10.1 5
10.2 5
13 12.6
14 12.6
15 12.6
3
---------------------- Page: 5 ----------------------
SIST EN ISO 18777:2005
EN ISO 18777:2005 (E)
16 12.6, 12.7
17 12.6
18 12.6
19 12.6
20 12.6
21 12.7
22 12.7
23 12.7
24 12.7
25 12.7
26 12.7.2, 12.7.3
27 12.8
28 12.7
29 11
36 9.2, 12.5
38 13
39 9.2, 9.3, 12.6, 12.7
40 9.2, 9.3, 12.6, 12.7
41 9.2, 9.3, 12.6, 12.7
42 12.7
43 9.3, 12.7
44.3 7.6, 12.6
44.6 7.6, 12.6
44.7 8.1
44.8 7.1, 7.3, 7.5, 9.3
45 12.7
46 9, 10, 12.9
47 12.5
48 7.1, 7.5
49 9.2, 12.8
50 10
51 10, 12.8
52 12.1, 12.6, 12.7, 12.8
53 5
4
---------------------- Page: 6 ----------------------
SIST EN ISO 18777:2005
EN ISO 18777:2005 (E)
54 9
55 9
56 9
56.3 9.1
56.7 12.2
57 12.6, 12.7
58 12.6, 12.7
101.2.1 9.2, 12.8
101.2.3 12.8
101.2.4 12.8
101.2.6 12.8
101.2.7 12.2
101.2.8 9.3, 12.6, 12.8
101.3 12.3, 12.8
5
---------------------- Page: 7 ----------------------
SIST EN ISO 18777:2005
---------------------- Page: 8 ----------------------
SIST EN ISO 18777:2005
INTERNATIONAL ISO
STANDARD 18777
First edition
2005-02-15
Transportable liquid oxygen systems for
medical use — Particular requirements
Systèmes transportables d'oxygène liquide à usage médical —
Exigences particulières
Reference number
ISO 18777:2005(E)
©
ISO 2005
---------------------- Page: 9 ----------------------
SIST EN ISO 18777:2005
ISO 18777:2005(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2005
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2005 – All rights reserved
---------------------- Page: 10 ----------------------
SIST EN ISO 18777:2005
ISO 18777:2005(E)
Contents Page
Foreword. v
Introduction . vi
1 Scope. 1
2 Normative references . 1
3 Terms and definitions. 2
4 General requirements and general requirements for tests . 3
5 Classification. 3
6 Identification, marking and documents. 3
7 Power input. 8
8 Basic safety categories . 8
9 Removable protective means . 8
10 Environmental conditions. 8
11 Not used. 9
12 Not used. 9
13 General. 9
14 Requirements related to classification . 9
15 Limitation of voltage and/or energy . 9
16 Enclosures and protective covers . 9
17 Separation. 10
18 Protective earthing, functional earthing and potential equalization . 10
19 Continuous leakage currents and patient auxiliary currents . 10
20 Dielectric strength. 10
21 Mechanical strength . 10
22 Moving parts. 10
23 Surfaces, corners and edges. 10
24 Stability in normal use. 10
25 Expelled parts. 11
26 Vibration and noise. 11
27 Pneumatic and hydraulic power. 11
28 Suspended masses. 11
29 X-Radiation . 11
30 Alpha, beta, gamma, neutron radiation and other particle radiation. 11
31 Microwave radiation. 11
32 Light radiation (including lasers) . 11
33 Infrared radiation. 12
© ISO 2005 – All rights reserved iii
---------------------- Page: 11 ----------------------
SIST EN ISO 18777:2005
ISO 18777:2005(E)
34 Ultraviolet energy .12
35 Acoustical energy (including ultrasonics).12
36 Electromagnetic compatibility .12
37 Locations and basic requirements.12
38 Marking and accompanying documents.12
39 Common requirements for category AP and category APG equipment .12
40 Requirements and tests for category AP equipment, parts and components thereof.12
41 Requirements and tests for category APG equipment, parts and components thereof .12
42 Excessive temperatures .12
43 Fire prevention.13
44 Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization,
disinfection and compatibility.13
45 Pressure vessels and parts subject to pressure .14
46 Human errors .14
47 Electrostatic charges .15
48 Biocompatibility.15
49 Interruption of the power supply .15
50 Accuracy of operating data .15
51 Protection against hazardous output.15
52 Abnormal operation and fault conditions.15
53 Environmental tests .15
54 General .15
55 Enclosures and covers .15
56 Components and general assembly.16
57 Mains parts, components and layout.16
58 Protective earthing – Terminals and connections .16
59 Construction and layout .16
101 Additional requirements .16
Annex AA (informative) Rationale .19
Annex BB (informative) Environmental aspects.22
Annex CC (informative) Index of defined terms.24
Bibliography.25
iv © ISO 2005 – All rights reserved
---------------------- Page: 12 ----------------------
SIST EN ISO 18777:2005
ISO 18777:2005(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 18777 was prepared by the European Committee for Standardization (CEN) Technical Committee
CEN/TC 215, Respiratory and anaesthetic equipment, in collaboration with Technical Committee ISO/TC 121,
Anaesthetic and respiratory equipment, Subcommittee SC 3, Lung ventilators and related equipment, in
accordance with the Agreement on technical cooperation between ISO and CEN (Vienna Agreement).
© ISO 2005 – All rights reserved v
---------------------- Page: 13 ----------------------
SIST EN ISO 18777:2005
ISO 18777:2005(E)
Introduction
This International Standard specifies requirements for liquid oxygen systems which are used as a source of
supply for oxygen therapy.
Annex AA contains a rationale for some of the requirements. It is included to provide additional insight into the
committee’s reasoning that led to a requirement and identifying the hazards that the requirement addresses.
Clauses and subclauses marked with * after their number have corresponding rationale contained in
Annex AA.
This International Standard is a Particular Standard based on IEC 60601-1:1988, including Amendments 1
(1991) and 2 (1995), hereafter referred to as the General Standard. The General Standard is the basic
standard for the safety of all medical electrical equipment used by or under the supervision of qualified
personnel in the general medical and patient environment; it also contains certain requirements for reliable
operation to ensure safety.
The General Standard has associated Collateral Standards and Particular Standards. The Collateral
Standards include requirements for specific technologies and/or hazards and apply to all applicable equipment,
such as medical electrical systems, EMC, radiation protection in diagnostic X-ray equipment, software, etc.
The Particular Standards apply to specific equipment types, such as medical electron accelerators, high
frequency surgical equipment, hospital beds, etc.
NOTE Definitions of Collateral Standard and Particular Standard can be found in IEC 60601-1:1988, 1.5 and A.2,
respectively.
To facilitate the use of this International Standard, the following drafting conventions have been applied.
This International Standard uses the same main clause titles and numbering as the General Standard, for
ease of cross-referencing of the requirements. The changes to the text of the General Standard, as
supplemented by the Collateral Standards, are specified by the use of the following words.
“Replacement” means that the indicated clause or subclause of the General Standard is replaced
completely by the text of this International Standard.
“Addition” means that the relevant text of this Particular Standard is a new element (e.g. subclause, list
item, note, table, figure) additional to the General Standard.
“Amendment” means that an existing element of the General Standard is partially modified by deletion
and/or addition as indicated by the text of this Particular Standard.
To avoid confusion with any amendments to the General Standard itself, a particular numbering has been
employed for elements added by this International Standard: subclauses, tables and figures are numbered
starting from 101; additional list items are lettered aa), bb), etc. and additional annexes are lettered AA, BB,
etc.
In this International Standard, the following print types are used:
requirements, compliance with which can be verified, and definitions: roman type;
notes and examples: smaller roman type;
description of type of document change and test methods: italic type;
vi © ISO 2005 – All rights reserved
---------------------- Page: 14 ----------------------
SIST EN ISO 18777:2005
ISO 18777:2005(E)
terms defined in the General Standard IEC 60601-1:1988, Clause 2, or in this Particular Standard: bold
type.
Throughout this International Standard, text for which a rationale is provided in Annex AA is indicated by an
asterisk (*).
© ISO 2005 – All rights reserved vii
---------------------- Page: 15 ----------------------
SIST EN ISO 18777:2005
---------------------- Page: 16 ----------------------
SIST EN ISO 18777:2005
INTERNATIONAL STANDARD ISO 18777:2005(E)
Transportable liquid oxygen systems for medical use —
Particular requirements
1 Scope
IEC 60601-1:1988, Clause 1, applies except as follows:
Amendments (add at end of 1.1):
1.1
This International Standard specifies requirements for the safety and essential performance of transportable
liquid oxygen systems which are used as a supply source for oxygen therapy. These devices usually consist
of a portable unit to be carried by or with the patient whilst in use and the vessel used to refill the portable
unit. These devices are mostly used in home care applications and in health care facilities/institutions. These
devices are often used without professional supervision.
Liquid oxygen vessels used as a supply source for oxygen pipeline systems are excluded from this
International Standard.
The requirements of this International Standard which replace or modify the requirements of
IEC 60601-1:1998 and its Amendments 1 (1991) and 2 (1995) are intended to take precedence over the
corresponding general requirements.
1.4
Addition:
NOTE Planning and design of products complying with this Internatinal Standard can have environmental impact
during the product life cycle. Environmental aspects are addressed in Annex BB. Additional aspects of environmental
impact are addressed in ISO 14971.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 980:2003, Graphical symbols for use in the labelling of medical devices
EN 1041:1998, Information supplied by the manufacturer with medical devices
EN 1251-1:2000, Cryogenic vessels — Transportable vacuum insulated vessels of not more than 1 000 litres
volume — Part 1: Fundamental requirements
EN 1251-2:2000, Cryogenic vessels — Transportable vacuum insulated vessels of not more than 1 000 litres
volume — Part 2: Design, fabrication, inspection and testing
EN 1251-3:2000, Cryogenic vessels — Transportable vacuum insulated vessels of not more than 1 000 litres
volume — Part 3: Operational requirements
© ISO 2005 – All rights reserved 1
---------------------- Page: 17 ----------------------
SIST EN ISO 18777:2005
ISO 18777:2005(E)
ISO 4135:2001, Anaesthetic and respiratory equipment — Vocabulary
ISO 7000, Graphical symbols for use on equipment — Index and synopsis
ISO 15001:2003, Anaesthetic and respiratory equipment — Compatibility with oxygen
ISO 18779, Medical devices for conserving oxygen and oxygen mixtures — Particular requiremenrts
EN 13544-2:2002, Respiratory therapy equipment — Part 2: Tubing and connectors
IEC 60601-1:1988 + A1:1991 + A2:1995 + corrigendum 1995 mod), Medical electrical equipment — Part 1:
General requirements for safety
IEC 60529:2001, Degrees of protection provided by enclosures (IP code)
IEC 60079-4:1975, Electrical apparatus for explosive gas atmospheres — Part 4: Method of test for ignition
temperature
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60601-1:1988, ISO 4135 and the
following apply.
3.1
applied part
part of the transportable liquid oxygen system intended to be connected to the patient and which in normal
use
necessarily comes into physical contact with the patient for the transportable liquid oxygen system to
perform its function or
can be brought into contact with the patient or
needs to be touched by the patient.
[Adapted from IEC 60601-1:1988]
3.2
base unit
mobile device that is a vacuum-insulated cryogenic vessel intended to store oxygen and maintain it in the
liquid state for the purpose of refilling portable units and that can also include an internal vaporizer and a flow
control for the direct supply of gaseous oxygen to the patient
3.3
expected service life
period during which the performance of the transportable liquid oxygen system or any of its components is
expected to meet the requirements of this International Standard when used and maintained according to the
accompanying documents
3.4
liquid oxygen transfer connector
connector used to transfer liquid oxygen from the base unit to the portable unit or to refill the base unit
3.5
portable unit
portable device including a vacuum-insulated cryogenic vessel to maintain liquid oxygen at cryogenic
temperatures, an internal vaporizer and a flow control to provide gaseous oxygen to the patient
2 © ISO 2005 – All rights reserved
---------------------- Page: 18 ----------------------
SIST EN ISO 18777:2005
ISO 18777:2005(E)
3.6
transportable liquid oxygen system
system comprising one or more portable units and compatible base units for oxygen therapy
4 General requirements and general requirements for tests
IEC 60601-1:1988, Clauses 3 and 4 apply, except as follows:
Addition:
4.101 Other test methods
Test methods other than those specified in this International Standard, but of equal or greater accuracy may
be used to verify compliance with requirements.
5 Classification
IEC 60601-1:1988, Clause 5 applies, except as follows:
Replacement:
5.2 Applied part classification
The equipment and its applied parts shall be classified as type BF or type CF.
6 Identification, marking and documents
IEC 60601-1:1988, Clause 6 applies, except as follows
Addition:
Information and marking shall comply with EN 980, EN 1041 and EN 1251-1.
6.1 Marking on the outside of equipment or equipment parts
Replacement:
d) if the size of the portable unit does not permit the complete marking as specified throughout this clause,
at least the following shall be marked on the portable unit:
the name of the manufacturer;
a serial or lot or batch identifying number;
symbol ISO 7000-0434 (or see Table D1, Symbol 14 in of IEC 60601-1:1988
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.