Workplace air -- Determination of particulate lead and lead compounds -- Flame or electrothermal atomic absorption spectrometric method

Air des lieux de travail -- Dosage du plomb particulaire et des composés particulaires du plomb -- Méthode par spectrométrie d'absorption atomique dans la flamme ou méthode par spectrométrie d'absorption avec atomisation électrothermique

Zrak na delovnem mestu – Določevanje svinca in svinčevih spojin v delcih – Plamenska ali elektrotermijska atomska absorpcijska spektrometrijska metoda

General Information

Status
Withdrawn
Publication Date
30-Apr-2002
Withdrawal Date
15-Aug-2023
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
01-Aug-2023
Due Date
24-Aug-2023
Completion Date
16-Aug-2023

Relations

Buy Standard

Standard
ISO 8518:2002
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 8518:2001 - Workplace air -- Determination of particulate lead and lead compounds -- Flame or electrothermal atomic absorption spectrometric method
English language
30 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 8518:2001 - Air des lieux de travail -- Dosage du plomb particulaire et des composés particulaires du plomb -- Méthode par spectrométrie d'absorption atomique dans la flamme ou méthode par spectrométrie d'absorption avec atomisation électrothermique
French language
32 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

SLOVENSKI STANDARD
SIST ISO 8518:2002
01-maj-2002
=UDNQDGHORYQHPPHVWX±'RORþHYDQMHVYLQFDLQVYLQþHYLKVSRMLQYGHOFLK±
3ODPHQVNDDOLHOHNWURWHUPLMVNDDWRPVNDDEVRUSFLMVNDVSHNWURPHWULMVNDPHWRGD
Workplace air -- Determination of particulate lead and lead compounds -- Flame or
electrothermal atomic absorption spectrometric method
Air des lieux de travail -- Dosage du plomb particulaire et des composés particulaires du
plomb -- Méthode par spectrométrie d'absorption atomique dans la flamme ou méthode
par spectrométrie d'absorption avec atomisation électrothermique
Ta slovenski standard je istoveten z: ISO 8518:2001
ICS:
13.040.30 Kakovost zraka na delovnem Workplace atmospheres
mestu
SIST ISO 8518:2002 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO 8518:2002

---------------------- Page: 2 ----------------------

SIST ISO 8518:2002
INTERNATIONAL ISO
STANDARD 8518
Second edition
2001-12-15
Workplace air — Determination of
particulate lead and lead compounds —
Flame or electrothermal atomic absorption
spectrometric method
Air des lieux de travail — Dosage du plomb particulaire et des composés
particulaires du plomb — Méthode par spectrométrie d'absorption atomique
dans la flamme ou méthode par spectrométrie d'absorption avec
atomisation électrothermique

Reference number
ISO 8518:2001(E)
©
ISO 2001

---------------------- Page: 3 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not be
edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file,
parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters
were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event
that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2001
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's
member body in the country of the requester.
ISO copyright office
Case postale 56  CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.ch
Web www.iso.ch
Printed in Switzerland
©
ii ISO 2001 – All rights reserved

---------------------- Page: 4 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
Contents Page
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Principle . 5
5 Reactions . 6
6 Requirement . 6
7 Reagents . 6
8 Apparatus . 7
9 Occupational exposure assessment . 11
9.1 Assessment strategy . 11
9.2 Measurement strategy . 11
9.3 Selection of measurement conditions and measurement pattern . 11
10 Sampling . 12
10.1 Preliminary considerations . 12
10.2 Preparation of sampling equipment . 13
10.3 Sampling position . 14
10.4 Collection of samples . 14
10.5 Transportation . 14
11 Analysis . 15
11.1 Cleaning of glassware and plasticware . 15
11.2 Preparation of sample and blank solutions . 15
11.3 Instrumental analysis . 17
11.4 Estimation of the instrumental detection limit . 20
11.5 Estimation of the method detection limit . 20
11.6 Quality control . 20
12 Expression of results . 21
12.1 Calculation . 21
12.2 Method performance . 22
13 Special cases . 23
14 Test report . 23
Annexes
A Guidance on filter selection. 25
B Temperature and pressure correction . 27
Bibliography. 29
©
ISO 2001 – All rights reserved iii

---------------------- Page: 5 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
International Standard ISO 8518 was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee
SC 2, Workplace atmospheres.
This second edition cancels and replaces the first edition (ISO 8518:1990), which has been technically revised.
Annexes A and B of this International Standard are for information only.
©
iv ISO 2001 – All rights reserved

---------------------- Page: 6 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
Introduction
The health of workers in many industries, e.g. mining, metal refining, battery manufacture, construction, etc., is at risk
through exposure by inhalation of particulate lead and lead compounds. Industrial hygienists and other public health
professionals need to determine the effectiveness of measures taken to control workers' exposure, and this is
generally achieved by making workplace air measurements. This International Standard provides a method for
making valid exposure measurements for lead. It will be of benefit to: agencies concerned with health and safety at
work; industrial hygienists and other public health professionals; analytical laboratories; industrial users and workers
of metals and metalloids, etc.
It has been assumed in the drafting of this International Standard that the execution of its provisions, and the
interpretation of the results obtained, is entrusted to appropriately qualified and experienced people.
©
ISO 2001 – All rights reserved v

---------------------- Page: 7 ----------------------

SIST ISO 8518:2002

---------------------- Page: 8 ----------------------

SIST ISO 8518:2002
INTERNATIONAL STANDARD ISO 8518:2001(E)
Workplace air — Determination of particulate lead and lead
compounds — Flame or electrothermal atomic absorption
spectrometric method
1 Scope
1.1 This International Standard specifies flame and electrothermal atomic absorption spectrometric methods for
the determination of the time-weighted average mass concentration of particulate lead and lead compounds in
workplace air.
1.2 The method is applicable to personal sampling of the inhalable fraction of airborne particles, as defined in
ISO 7708, and to static (area) sampling.
1.3 The sample dissolution procedure specifies hot plate or microwave digestion, or ultrasonic extraction (11.2).
The use of an alternative, more vigorous dissolution procedure is necessary when it is desired to extract lead from
compounds present in the test atmosphere that are insoluble using the dissolution procedures described herein.
1.4 The flame atomic absorption method is applicable to the determination of masses of approximately 1µg to
200µg of lead per sample, without dilution [1]. The electrothermal atomic absorption method is applicable to the
determination of masses of approximately 0,01µg to 0,5µg of lead per sample, without dilution [1].
1.5 The ultrasonic extraction procedure has been validated for the determination of masses of approximately 20µg
to 100µg of lead per sample, for laboratory-generated lead fume air filter samples [2].
1.6 The concentration range for lead in air for which this procedure is applicable is determined in part by the
sampling procedure selected by the user (see 10.1).
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of
this International Standard. For dated references, subsequent amendments to, or revisions of, any of these
publications do not apply. However, parties to agreements based on this International Standard are encouraged to
investigate the possibility of applying the most recent editions of the normative documents indicated below. For
undated references, the latest edition of the normative document referred to applies. Members of ISO and IEC
maintain registers of currently valid International Standards.
ISO 648:1977, Laboratory glassware — One-mark pipettes
ISO 1042:1998, Laboratory glassware — One-mark volumetric flasks
ISO 3585:1998, Borosilicate glass 3.3 — Properties
ISO 3696:1987, Water for analytical laboratory use — Specification and test methods
ISO 7708:1995, Air quality — Particle size fraction definitions for health-related sampling
ISO 8655-1, Piston-operated volumetric apparatus— Part1: Terminology, general requirements and user
recommendations
ISO 8655-2, Piston-operated volumetric apparatus — Part 2: Piston pipettes
©
ISO 2001 – All rights reserved 1

---------------------- Page: 9 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
ISO 8655-5, Piston-operated volumetric apparatus — Part 5: Dispensers
ISO 8655-6, Piston-operated volumetric apparatus— Part6: Gravimetric methods for the determination of
measurement error
ISO 15202-2:2001, Workplace air — Determination of metals and metalloids in airborne particulate matter by
inductively coupled plasma atomic emission spectrometry — Part 2: Sample preparation
1)
EN 13205 , Workplace atmospheres — Assessment of performance of instruments for measurement of airborne
particle concentrations
3 Terms and definitions
For the purposes of this International Standard, the following terms and definitions apply.
3.1 General definitions
3.1.1
chemical agent
any chemical element or compound, on its own or admixed as it occurs in the natural state or as produced, used or
released, including release as waste, by any work activity, whether or not produced intentionally and whether or not
placed on the market
[EN 1540]
3.1.2
breathing zone
space around a person's face from where he or she takes his or her breath
NOTE For technical purposes, a more precise definition is as follows: hemisphere (generally accepted to be 0,3 m in radius)
extending in front of the human face, centred on the midpoint of a line joining the ears; the base of the hemisphere is a plane
through this line, the top of the head and the larynx. This definition is not applicable when respiratory protective equipment is used.
[EN 1540]
3.1.3
exposure by inhalation
situation in which a chemical agent is present in air which is inhaled by a person
3.1.4
measuring procedure
procedure for sampling and analysing one or more chemical agents in the air, including storage and transportation of
the sample
3.1.5
operating time
period during which a sampling pump can be operated at specified flowrate and back-pressure without recharging or
replacing the battery
[EN 1232]
3.1.6
time-weighted average concentration
TWA concentration
concentration of a chemical agent in the atmosphere, averaged over the reference period
1) To be published.
©
2 ISO 2001 – All rights reserved

---------------------- Page: 10 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
NOTE A more detailed discussion of TWA concentrations and their use can be found in [3].
3.1.7
limit value
reference figure for concentration of a chemical agent in air
®
EXAMPLE Threshold Limit Value (TLV) for a given substance in workplace air, as established by the ACGIH [3].
3.1.8
reference period
specified period of time stated for the limit value of a specific chemical agent
NOTE Examples of limit values for different reference periods are short-term and long-term exposure limits, such as those
established by the ACGIH [3].
3.1.9
workplace
defined area or areas in which work activities are carried out
[EN 1540]
3.2 Particle size fraction definitions
3.2.1
inhalable convention
target specification for sampling instruments when the inhalable fraction is of interest
[ISO 7708]
3.2.2
inhalable fraction
mass fraction of total airborne particles which is inhaled through the nose and mouth
NOTE The inhalable fraction depends on the speed and direction of air movement, on breathing rate and other factors.
[ISO 7708]
3.2.3
respirable convention
target specification for sampling instruments when the respirable fraction is of interest
[ISO 7708]
3.2.4
respirable fraction
mass fraction of inhaled particles penetrating to the unciliated airways
[ISO 7708]
3.2.5
total airborne particles
all particles surrounded by air in a given volume of air
NOTE Because all measuring instruments are size-selective to some extent, it is often impossible to measure the total
concentration of airborne particles.
[ISO 7708]
©
ISO 2001 – All rights reserved 3

---------------------- Page: 11 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
3.3 Sampling definitions
3.3.1
personal sampler
device attached to a person that samples air in the breathing zone
[EN 1540]
3.3.2
personal sampling
process of sampling carried out using a personal sampler
[EN 1540]
3.3.3
sampling instrument
sampler
device for collecting airborne particles
NOTE Instruments used to collect airborne particles are frequently referred to by a number of other terms, e.g. sampling heads,
filter holders, filter cassettes, etc.
3.3.4
static sampling
area sampling
process of air sampling carried out in a particular location
3.3.5
static sampler
area sampler
device, not attached to a person, used in static sampling
3.4 Definitions used in analysis
3.4.1
sample dissolution
process of obtaining a solution containing the analytes of interest from a sample
NOTE This may or may not involve complete dissolution of the sample.
3.4.2
sample preparation
all operations carried out on a sample, after transportation and storage, to prepare it for analysis, including
transformation of the sample into a measurable state, where necessary
3.4.3
sample solution
solution prepared by the process of sample dissolution, but possibly needing to be subjected to further operations in
order to produce a test solution that is ready for analysis
3.4.4
test solution
solution prepared by the process of sample dissolution and, if necessary, having been subjected to any further
operations required to bring it into a state in which it is ready for analysis
3.5 Statistical terms
3.5.1
analytical recovery
ratio of the mass of analyte measured when a sample is analysed to the known mass of analyte in that sample
NOTE It is expressed as a percentage.
©
4 ISO 2001 – All rights reserved

---------------------- Page: 12 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
3.5.2
bias
consistent deviation of the results of a measurement process from the true value of the air quality characteristic itself
[ISO 6879]
3.5.3
overall uncertainty
〈of a measuring procedure or of an instrument〉 quantity used to characterize as a whole the uncertainty of a result
given by an apparatus or measuring procedure
NOTE It is expressed, as a percentage, by a combination of bias and precision, usually according to the formula:
|x−x |+ 2s
ref
× 100
x
ref
where
xnis the mean value of results of a number ( ) of repeated measurements;
x is the true or accepted reference value of concentration; and
ref
s is the standard deviation of repeated measurements.
[EN 482]
3.5.4
precision
closeness of agreement of results obtained by applying the same method several times under prescribed conditions
[ISO 6879]
NOTE Precision is often expressed in terms of the relative standard deviation.
3.5.5
true value
value which characterizes a quantity perfectly defined in the conditions which exist when that quantity is considered
[ISO 3534-1]
NOTE The true value of a quantity is a theoretical concept and, in general, cannot be known exactly (see EN 1540).
4 Principle
4.1 A known volume of air is drawn through a filter to collect particulate lead and lead compounds. For personal
sampling, a sampler designed to collect the inhalable fraction of airborne particles is used.
4.2 The filter and collected sample are subjected to a dissolution procedure in order to extract lead. The sample
dissolution procedure may use one of three techniques: hot plate digestion, microwave digestion or ultrasonic
extraction.
4.3 Sample solutions are analysed for lead content by aspirating into the oxidizing air-acetylene flame of an atomic
absorption spectrometer equipped with a lead hollow-cathode lamp or electrodeless discharge lamp. Absorbance
measurements are made at 283,3 nm, and analytical results are obtained by the analytical curve technique (see 6.1
of ISO 6955:1982). Potential interference by anions that form precipitates with lead is overcome by the addition of the
disodium salt of ethylenediamine tetraacetic acid (EDTA) when necessary.
4.4 For accurate lead determination when the concentration of lead in the solution is low, the analysis may be
repeated using electrothermal atomic absorption spectrometry. Aliquots of the test solution are injected into a
©
ISO 2001 – All rights reserved 5

---------------------- Page: 13 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
graphite furnace, and after drying and sample ashing stages, the sample is atomized electrothermally. Absorbance
measurements are made at 283,3 nm with background correction, and results are obtained by the analytical curve
technique (see 6.1 of ISO 6955:1982).
4.5 The results may be used for the assessment of workplace exposures to airborne particulate lead (see EN 689).
5 Reactions
In general, the overwhelming majority of particulate lead compounds that are commonly found in samples of
2+
workplace air are converted to water-soluble lead ions (Pb ) by the sample dissolution procedures described in
11.2. However, certain lead compounds, for example lead silicate, might not be dissolved. If necessary, a dissolution
procedure employing hydrofluoric acid should be used to dissolve silicate lead. If there is any doubt about the
effectiveness of these procedures for the dissolution of particulate lead compounds that may be present in the test
atmosphere, then this shall be investigated before proceeding with the analytical method described in clause 11.
6 Requirement
The measuring procedure shall comply with any relevant international, european or national standard that specifies
performance requirements for procedures for measuring chemical agents in workplace air (e.g. EN 482).
7Reagents
During the analysis, use only reagents of recognized analytical grade, and only water as specified in 7.1.
7.1 Water, complying with the requirements for ISO 3696 grade 2 water (electrical conductivity less than 0,1 mS/m

and resistivity greater than 0,01 MΩ·m2 at 5 C).
The concentration of lead in the water shall be less than 0, 01µg/ml.
It is recommended that the water used be obtained from a water purification system that delivers ultrapure water
having a resistivity greater than 0,18 MΩ·m (usually expressed by manufacturers of water purification systems as
18 MΩ·cm).
7.2 Nitric acid (HNO ), concentrated, ρ≈ 1,42 g/ml (about 70 % mass fraction).
3
The concentration of lead shall be less than 0,01µg/ml.
WARNING — Concentrated nitric acid is corrosive and oxidizing, and nitric acid fumes are irritant. Avoid
exposure by contact with the skin or eyes, or by inhalation of fumes. Use suitable personal protective
equipment (including suitable gloves, face shield or safety glasses, etc.) when working with the
concentrated or dilute nitric acid, and carry out sample dissolution with concentrated nitric acid in open
vessels in a fume hood.
7.3 Nitric acid, diluted 1+ 1.
Carefully add 500 ml of concentrated nitric acid (7.2) to 450 ml of water (7.1) in a 2-litre beaker. Swirl to mix, allow to
cool and transfer to a 1-litre one-mark volumetric flask (8.6.1.4). Dilute to the mark with water, stopper and mix
thoroughly.
7.4 Nitric acid, diluted 1+ 9.
Place approximately 800 ml of water (7.1) in a 1-litre one-mark volumetric flask (8.6.1.4). Carefully add 100 ml of
concentrated nitric acid (7.2) to the flask and swirl to mix. Allow to cool, dilute to 1 litre with water and mix thoroughly.
7.5 Hydrofluoric acid (HF), concentrated, ρ≈ 1,16 g/ml (about 48 % mass fraction), if required, for digestion of
samples containing lead silicates.
©
6 ISO 2001 – All rights reserved

---------------------- Page: 14 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
The concentration of lead in the HF shall be less than 0, 1µg/ml.
WARNING — Concentrated hydrofluoric acid and hydrogen fluoride vapour are extremely toxic and intensely
corrosive, and diluted hydrofluoric acid can also cause serious and painful burns that might not be felt until
up to 24 h after contact. Avoid exposure by contact with the skin or the eyes, or by inhalation of the vapour.
Use of personal protection (e.g. impermeable gloves, face shield or safety glasses, etc.) is essential when
working with concentrated or diluted hydrofluoric acid, and concentrated hydrofluoric acid should be used
in a fume hood. It is essential that hydrofluoric acid antidote gel containing calcium gluconate is readily
available to workers, both during and for 24 h after use of hydrofluoric acid.
7.6 Matrix modifier, NH H PO , Mg(NO ) or Pd(NO ) , or a combination of these, if required, for analysis by
4 2 4 3 2 3 2
electrothermal atomic absorption spectrometry.
7.7 Stock lead standard solution, 1 000 mg/l of lead.
Use a commercial standard solution with a certified lead concentration traceable to national standards. Observe the
manufacturer's expiration date or recommended shelf life.
Alternatively, prepare a lead standard solution by one of the following procedures.

a) Dissolve 1,598 g± 0,001 g of lead(II) nitrate [Pb(NO ) ], previously dried to constant mass at 110 C and
3 2
cooled in a desiccator, in 200 ml of 1+ 1 nitric acid (7.3). Quantitatively transfer the solution to a 1000 ml one-
mark volumetric flask (8.6.1.4). Dilute to the mark with water (7.1), stopper and mix thoroughly. Store in a suitable
container, e.g. a polypropylene bottle (8.6.2.2), for a maximum period of one year.
b) Dissolve 1,000 g± 0,001 g of lead wire (99,9 % mass fraction Pb) in 200 ml of 1+ 1 nitric acid (7.3).
Quantitatively transfer the solution into a 1 000 ml one-mark volumetric flask (8.6.1.4), dilute to the mark with
water (7.1), stopper and mix thoroughly. Store in a suitable container, e.g. a polypropylene bottle (8.6.2.2), for a
maximum period of one year.
7.8 Working lead standard solution, 1 mg/l of lead, if required, for analysis by electrothermal atomic absorption
spectrometry.
Accurately pipette 100µl of stock lead standard solution (7.7) into a 100 ml one-mark volumetric flask (8.6.1.4). Add
1ml of concentrated nitric acid (7.2), dilute to the mark with water (7.1), stopper and mix thoroughly. Store in a
suitable container, e.g. a polypropylene bottle (8.6.2.2), for a maximum period of one month.
7.9 Hydrogen peroxide (H O ), approximately 30 % mass fraction solution, if required, for use in the hot-plate
2 2
sample digestion method.
The concentration of lead in the hydrogen peroxide solution shall be less than 0,01µg/ml.
7.10 Acetylene, if required, for use in analysis by flame atomic absorption spectrometry.
7.11 Air, compressed and filtered, if required, for use in analysis by flame atomic absorption spectrometry.
8Apparatus
8.1 Inhalable samplers, designed to collect the inhalable fraction of airborne particles, complying with the
provisions of EN 13205, for use when the exposure limits of interest apply to the inhalable fraction of airborne
particles.
NOTE 1 In general, personal samplers for collection of the inhalable fraction of airborne particles do not exhibit the same size-
selective characteristics if used for static (area) sampling.
NOTE 2 Some inhalable samplers are designed to collect the fraction of airborne particles on a filter, and any particulate matter
deposited on the internal surfaces of the sampler is not of interest. Other inhalable samplers are designed such that airborne
particles that pass through the entry orifice(s) match the inhalable convention, in which case particulate matter deposited on the
internal surfaces of the sampler does form part of the sample. (Samplers of this second type generally incorporate an internal filter
cassette or cartridge that can be removed from the sampler to enable this material to be easily recovered.) The operating
©
ISO 2001 – All rights reserved 7

---------------------- Page: 15 ----------------------

SIST ISO 8518:2002
ISO 8518:2001(E)
instructions supplied by the manufacturer should be consulted to find out whether particulate matter deposited on the internal
surfaces of the sampler f
...

INTERNATIONAL ISO
STANDARD 8518
Second edition
2001-12-15
Workplace air — Determination of
particulate lead and lead compounds —
Flame or electrothermal atomic absorption
spectrometric method
Air des lieux de travail — Dosage du plomb particulaire et des composés
particulaires du plomb — Méthode par spectrométrie d'absorption atomique
dans la flamme ou méthode par spectrométrie d'absorption avec
atomisation électrothermique

Reference number
ISO 8518:2001(E)
©
ISO 2001

---------------------- Page: 1 ----------------------
ISO 8518:2001(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not be
edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file,
parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters
were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event
that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2001
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's
member body in the country of the requester.
ISO copyright office
Case postale 56  CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.ch
Web www.iso.ch
Printed in Switzerland
©
ii ISO 2001 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 8518:2001(E)
Contents Page
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Principle . 5
5 Reactions . 6
6 Requirement . 6
7 Reagents . 6
8 Apparatus . 7
9 Occupational exposure assessment . 11
9.1 Assessment strategy . 11
9.2 Measurement strategy . 11
9.3 Selection of measurement conditions and measurement pattern . 11
10 Sampling . 12
10.1 Preliminary considerations . 12
10.2 Preparation of sampling equipment . 13
10.3 Sampling position . 14
10.4 Collection of samples . 14
10.5 Transportation . 14
11 Analysis . 15
11.1 Cleaning of glassware and plasticware . 15
11.2 Preparation of sample and blank solutions . 15
11.3 Instrumental analysis . 17
11.4 Estimation of the instrumental detection limit . 20
11.5 Estimation of the method detection limit . 20
11.6 Quality control . 20
12 Expression of results . 21
12.1 Calculation . 21
12.2 Method performance . 22
13 Special cases . 23
14 Test report . 23
Annexes
A Guidance on filter selection. 25
B Temperature and pressure correction . 27
Bibliography. 29
©
ISO 2001 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 8518:2001(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
International Standard ISO 8518 was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee
SC 2, Workplace atmospheres.
This second edition cancels and replaces the first edition (ISO 8518:1990), which has been technically revised.
Annexes A and B of this International Standard are for information only.
©
iv ISO 2001 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 8518:2001(E)
Introduction
The health of workers in many industries, e.g. mining, metal refining, battery manufacture, construction, etc., is at risk
through exposure by inhalation of particulate lead and lead compounds. Industrial hygienists and other public health
professionals need to determine the effectiveness of measures taken to control workers' exposure, and this is
generally achieved by making workplace air measurements. This International Standard provides a method for
making valid exposure measurements for lead. It will be of benefit to: agencies concerned with health and safety at
work; industrial hygienists and other public health professionals; analytical laboratories; industrial users and workers
of metals and metalloids, etc.
It has been assumed in the drafting of this International Standard that the execution of its provisions, and the
interpretation of the results obtained, is entrusted to appropriately qualified and experienced people.
©
ISO 2001 – All rights reserved v

---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 8518:2001(E)
Workplace air — Determination of particulate lead and lead
compounds — Flame or electrothermal atomic absorption
spectrometric method
1 Scope
1.1 This International Standard specifies flame and electrothermal atomic absorption spectrometric methods for
the determination of the time-weighted average mass concentration of particulate lead and lead compounds in
workplace air.
1.2 The method is applicable to personal sampling of the inhalable fraction of airborne particles, as defined in
ISO 7708, and to static (area) sampling.
1.3 The sample dissolution procedure specifies hot plate or microwave digestion, or ultrasonic extraction (11.2).
The use of an alternative, more vigorous dissolution procedure is necessary when it is desired to extract lead from
compounds present in the test atmosphere that are insoluble using the dissolution procedures described herein.
1.4 The flame atomic absorption method is applicable to the determination of masses of approximately 1µg to
200µg of lead per sample, without dilution [1]. The electrothermal atomic absorption method is applicable to the
determination of masses of approximately 0,01µg to 0,5µg of lead per sample, without dilution [1].
1.5 The ultrasonic extraction procedure has been validated for the determination of masses of approximately 20µg
to 100µg of lead per sample, for laboratory-generated lead fume air filter samples [2].
1.6 The concentration range for lead in air for which this procedure is applicable is determined in part by the
sampling procedure selected by the user (see 10.1).
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of
this International Standard. For dated references, subsequent amendments to, or revisions of, any of these
publications do not apply. However, parties to agreements based on this International Standard are encouraged to
investigate the possibility of applying the most recent editions of the normative documents indicated below. For
undated references, the latest edition of the normative document referred to applies. Members of ISO and IEC
maintain registers of currently valid International Standards.
ISO 648:1977, Laboratory glassware — One-mark pipettes
ISO 1042:1998, Laboratory glassware — One-mark volumetric flasks
ISO 3585:1998, Borosilicate glass 3.3 — Properties
ISO 3696:1987, Water for analytical laboratory use — Specification and test methods
ISO 7708:1995, Air quality — Particle size fraction definitions for health-related sampling
ISO 8655-1, Piston-operated volumetric apparatus— Part1: Terminology, general requirements and user
recommendations
ISO 8655-2, Piston-operated volumetric apparatus — Part 2: Piston pipettes
©
ISO 2001 – All rights reserved 1

---------------------- Page: 6 ----------------------
ISO 8518:2001(E)
ISO 8655-5, Piston-operated volumetric apparatus — Part 5: Dispensers
ISO 8655-6, Piston-operated volumetric apparatus— Part6: Gravimetric methods for the determination of
measurement error
ISO 15202-2:2001, Workplace air — Determination of metals and metalloids in airborne particulate matter by
inductively coupled plasma atomic emission spectrometry — Part 2: Sample preparation
1)
EN 13205 , Workplace atmospheres — Assessment of performance of instruments for measurement of airborne
particle concentrations
3 Terms and definitions
For the purposes of this International Standard, the following terms and definitions apply.
3.1 General definitions
3.1.1
chemical agent
any chemical element or compound, on its own or admixed as it occurs in the natural state or as produced, used or
released, including release as waste, by any work activity, whether or not produced intentionally and whether or not
placed on the market
[EN 1540]
3.1.2
breathing zone
space around a person's face from where he or she takes his or her breath
NOTE For technical purposes, a more precise definition is as follows: hemisphere (generally accepted to be 0,3 m in radius)
extending in front of the human face, centred on the midpoint of a line joining the ears; the base of the hemisphere is a plane
through this line, the top of the head and the larynx. This definition is not applicable when respiratory protective equipment is used.
[EN 1540]
3.1.3
exposure by inhalation
situation in which a chemical agent is present in air which is inhaled by a person
3.1.4
measuring procedure
procedure for sampling and analysing one or more chemical agents in the air, including storage and transportation of
the sample
3.1.5
operating time
period during which a sampling pump can be operated at specified flowrate and back-pressure without recharging or
replacing the battery
[EN 1232]
3.1.6
time-weighted average concentration
TWA concentration
concentration of a chemical agent in the atmosphere, averaged over the reference period
1) To be published.
©
2 ISO 2001 – All rights reserved

---------------------- Page: 7 ----------------------
ISO 8518:2001(E)
NOTE A more detailed discussion of TWA concentrations and their use can be found in [3].
3.1.7
limit value
reference figure for concentration of a chemical agent in air
®
EXAMPLE Threshold Limit Value (TLV) for a given substance in workplace air, as established by the ACGIH [3].
3.1.8
reference period
specified period of time stated for the limit value of a specific chemical agent
NOTE Examples of limit values for different reference periods are short-term and long-term exposure limits, such as those
established by the ACGIH [3].
3.1.9
workplace
defined area or areas in which work activities are carried out
[EN 1540]
3.2 Particle size fraction definitions
3.2.1
inhalable convention
target specification for sampling instruments when the inhalable fraction is of interest
[ISO 7708]
3.2.2
inhalable fraction
mass fraction of total airborne particles which is inhaled through the nose and mouth
NOTE The inhalable fraction depends on the speed and direction of air movement, on breathing rate and other factors.
[ISO 7708]
3.2.3
respirable convention
target specification for sampling instruments when the respirable fraction is of interest
[ISO 7708]
3.2.4
respirable fraction
mass fraction of inhaled particles penetrating to the unciliated airways
[ISO 7708]
3.2.5
total airborne particles
all particles surrounded by air in a given volume of air
NOTE Because all measuring instruments are size-selective to some extent, it is often impossible to measure the total
concentration of airborne particles.
[ISO 7708]
©
ISO 2001 – All rights reserved 3

---------------------- Page: 8 ----------------------
ISO 8518:2001(E)
3.3 Sampling definitions
3.3.1
personal sampler
device attached to a person that samples air in the breathing zone
[EN 1540]
3.3.2
personal sampling
process of sampling carried out using a personal sampler
[EN 1540]
3.3.3
sampling instrument
sampler
device for collecting airborne particles
NOTE Instruments used to collect airborne particles are frequently referred to by a number of other terms, e.g. sampling heads,
filter holders, filter cassettes, etc.
3.3.4
static sampling
area sampling
process of air sampling carried out in a particular location
3.3.5
static sampler
area sampler
device, not attached to a person, used in static sampling
3.4 Definitions used in analysis
3.4.1
sample dissolution
process of obtaining a solution containing the analytes of interest from a sample
NOTE This may or may not involve complete dissolution of the sample.
3.4.2
sample preparation
all operations carried out on a sample, after transportation and storage, to prepare it for analysis, including
transformation of the sample into a measurable state, where necessary
3.4.3
sample solution
solution prepared by the process of sample dissolution, but possibly needing to be subjected to further operations in
order to produce a test solution that is ready for analysis
3.4.4
test solution
solution prepared by the process of sample dissolution and, if necessary, having been subjected to any further
operations required to bring it into a state in which it is ready for analysis
3.5 Statistical terms
3.5.1
analytical recovery
ratio of the mass of analyte measured when a sample is analysed to the known mass of analyte in that sample
NOTE It is expressed as a percentage.
©
4 ISO 2001 – All rights reserved

---------------------- Page: 9 ----------------------
ISO 8518:2001(E)
3.5.2
bias
consistent deviation of the results of a measurement process from the true value of the air quality characteristic itself
[ISO 6879]
3.5.3
overall uncertainty
〈of a measuring procedure or of an instrument〉 quantity used to characterize as a whole the uncertainty of a result
given by an apparatus or measuring procedure
NOTE It is expressed, as a percentage, by a combination of bias and precision, usually according to the formula:
|x−x |+ 2s
ref
× 100
x
ref
where
xnis the mean value of results of a number ( ) of repeated measurements;
x is the true or accepted reference value of concentration; and
ref
s is the standard deviation of repeated measurements.
[EN 482]
3.5.4
precision
closeness of agreement of results obtained by applying the same method several times under prescribed conditions
[ISO 6879]
NOTE Precision is often expressed in terms of the relative standard deviation.
3.5.5
true value
value which characterizes a quantity perfectly defined in the conditions which exist when that quantity is considered
[ISO 3534-1]
NOTE The true value of a quantity is a theoretical concept and, in general, cannot be known exactly (see EN 1540).
4 Principle
4.1 A known volume of air is drawn through a filter to collect particulate lead and lead compounds. For personal
sampling, a sampler designed to collect the inhalable fraction of airborne particles is used.
4.2 The filter and collected sample are subjected to a dissolution procedure in order to extract lead. The sample
dissolution procedure may use one of three techniques: hot plate digestion, microwave digestion or ultrasonic
extraction.
4.3 Sample solutions are analysed for lead content by aspirating into the oxidizing air-acetylene flame of an atomic
absorption spectrometer equipped with a lead hollow-cathode lamp or electrodeless discharge lamp. Absorbance
measurements are made at 283,3 nm, and analytical results are obtained by the analytical curve technique (see 6.1
of ISO 6955:1982). Potential interference by anions that form precipitates with lead is overcome by the addition of the
disodium salt of ethylenediamine tetraacetic acid (EDTA) when necessary.
4.4 For accurate lead determination when the concentration of lead in the solution is low, the analysis may be
repeated using electrothermal atomic absorption spectrometry. Aliquots of the test solution are injected into a
©
ISO 2001 – All rights reserved 5

---------------------- Page: 10 ----------------------
ISO 8518:2001(E)
graphite furnace, and after drying and sample ashing stages, the sample is atomized electrothermally. Absorbance
measurements are made at 283,3 nm with background correction, and results are obtained by the analytical curve
technique (see 6.1 of ISO 6955:1982).
4.5 The results may be used for the assessment of workplace exposures to airborne particulate lead (see EN 689).
5 Reactions
In general, the overwhelming majority of particulate lead compounds that are commonly found in samples of
2+
workplace air are converted to water-soluble lead ions (Pb ) by the sample dissolution procedures described in
11.2. However, certain lead compounds, for example lead silicate, might not be dissolved. If necessary, a dissolution
procedure employing hydrofluoric acid should be used to dissolve silicate lead. If there is any doubt about the
effectiveness of these procedures for the dissolution of particulate lead compounds that may be present in the test
atmosphere, then this shall be investigated before proceeding with the analytical method described in clause 11.
6 Requirement
The measuring procedure shall comply with any relevant international, european or national standard that specifies
performance requirements for procedures for measuring chemical agents in workplace air (e.g. EN 482).
7Reagents
During the analysis, use only reagents of recognized analytical grade, and only water as specified in 7.1.
7.1 Water, complying with the requirements for ISO 3696 grade 2 water (electrical conductivity less than 0,1 mS/m

and resistivity greater than 0,01 MΩ·m2 at 5 C).
The concentration of lead in the water shall be less than 0, 01µg/ml.
It is recommended that the water used be obtained from a water purification system that delivers ultrapure water
having a resistivity greater than 0,18 MΩ·m (usually expressed by manufacturers of water purification systems as
18 MΩ·cm).
7.2 Nitric acid (HNO ), concentrated, ρ≈ 1,42 g/ml (about 70 % mass fraction).
3
The concentration of lead shall be less than 0,01µg/ml.
WARNING — Concentrated nitric acid is corrosive and oxidizing, and nitric acid fumes are irritant. Avoid
exposure by contact with the skin or eyes, or by inhalation of fumes. Use suitable personal protective
equipment (including suitable gloves, face shield or safety glasses, etc.) when working with the
concentrated or dilute nitric acid, and carry out sample dissolution with concentrated nitric acid in open
vessels in a fume hood.
7.3 Nitric acid, diluted 1+ 1.
Carefully add 500 ml of concentrated nitric acid (7.2) to 450 ml of water (7.1) in a 2-litre beaker. Swirl to mix, allow to
cool and transfer to a 1-litre one-mark volumetric flask (8.6.1.4). Dilute to the mark with water, stopper and mix
thoroughly.
7.4 Nitric acid, diluted 1+ 9.
Place approximately 800 ml of water (7.1) in a 1-litre one-mark volumetric flask (8.6.1.4). Carefully add 100 ml of
concentrated nitric acid (7.2) to the flask and swirl to mix. Allow to cool, dilute to 1 litre with water and mix thoroughly.
7.5 Hydrofluoric acid (HF), concentrated, ρ≈ 1,16 g/ml (about 48 % mass fraction), if required, for digestion of
samples containing lead silicates.
©
6 ISO 2001 – All rights reserved

---------------------- Page: 11 ----------------------
ISO 8518:2001(E)
The concentration of lead in the HF shall be less than 0, 1µg/ml.
WARNING — Concentrated hydrofluoric acid and hydrogen fluoride vapour are extremely toxic and intensely
corrosive, and diluted hydrofluoric acid can also cause serious and painful burns that might not be felt until
up to 24 h after contact. Avoid exposure by contact with the skin or the eyes, or by inhalation of the vapour.
Use of personal protection (e.g. impermeable gloves, face shield or safety glasses, etc.) is essential when
working with concentrated or diluted hydrofluoric acid, and concentrated hydrofluoric acid should be used
in a fume hood. It is essential that hydrofluoric acid antidote gel containing calcium gluconate is readily
available to workers, both during and for 24 h after use of hydrofluoric acid.
7.6 Matrix modifier, NH H PO , Mg(NO ) or Pd(NO ) , or a combination of these, if required, for analysis by
4 2 4 3 2 3 2
electrothermal atomic absorption spectrometry.
7.7 Stock lead standard solution, 1 000 mg/l of lead.
Use a commercial standard solution with a certified lead concentration traceable to national standards. Observe the
manufacturer's expiration date or recommended shelf life.
Alternatively, prepare a lead standard solution by one of the following procedures.

a) Dissolve 1,598 g± 0,001 g of lead(II) nitrate [Pb(NO ) ], previously dried to constant mass at 110 C and
3 2
cooled in a desiccator, in 200 ml of 1+ 1 nitric acid (7.3). Quantitatively transfer the solution to a 1000 ml one-
mark volumetric flask (8.6.1.4). Dilute to the mark with water (7.1), stopper and mix thoroughly. Store in a suitable
container, e.g. a polypropylene bottle (8.6.2.2), for a maximum period of one year.
b) Dissolve 1,000 g± 0,001 g of lead wire (99,9 % mass fraction Pb) in 200 ml of 1+ 1 nitric acid (7.3).
Quantitatively transfer the solution into a 1 000 ml one-mark volumetric flask (8.6.1.4), dilute to the mark with
water (7.1), stopper and mix thoroughly. Store in a suitable container, e.g. a polypropylene bottle (8.6.2.2), for a
maximum period of one year.
7.8 Working lead standard solution, 1 mg/l of lead, if required, for analysis by electrothermal atomic absorption
spectrometry.
Accurately pipette 100µl of stock lead standard solution (7.7) into a 100 ml one-mark volumetric flask (8.6.1.4). Add
1ml of concentrated nitric acid (7.2), dilute to the mark with water (7.1), stopper and mix thoroughly. Store in a
suitable container, e.g. a polypropylene bottle (8.6.2.2), for a maximum period of one month.
7.9 Hydrogen peroxide (H O ), approximately 30 % mass fraction solution, if required, for use in the hot-plate
2 2
sample digestion method.
The concentration of lead in the hydrogen peroxide solution shall be less than 0,01µg/ml.
7.10 Acetylene, if required, for use in analysis by flame atomic absorption spectrometry.
7.11 Air, compressed and filtered, if required, for use in analysis by flame atomic absorption spectrometry.
8Apparatus
8.1 Inhalable samplers, designed to collect the inhalable fraction of airborne particles, complying with the
provisions of EN 13205, for use when the exposure limits of interest apply to the inhalable fraction of airborne
particles.
NOTE 1 In general, personal samplers for collection of the inhalable fraction of airborne particles do not exhibit the same size-
selective characteristics if used for static (area) sampling.
NOTE 2 Some inhalable samplers are designed to collect the fraction of airborne particles on a filter, and any particulate matter
deposited on the internal surfaces of the sampler is not of interest. Other inhalable samplers are designed such that airborne
particles that pass through the entry orifice(s) match the inhalable convention, in which case particulate matter deposited on the
internal surfaces of the sampler does form part of the sample. (Samplers of this second type generally incorporate an internal filter
cassette or cartridge that can be removed from the sampler to enable this material to be easily recovered.) The operating
©
ISO 2001 – All rights reserved 7

---------------------- Page: 12 ----------------------
ISO 8518:2001(E)
instructions supplied by the manufacturer should be consulted to find out whether particulate matter deposited on the internal
surfaces of the sampler forms part of the sample.
8.2 Filters, of a diameter suitable for use with the samplers (see 8.1), with a collection efficiency of not less than
99,5 % for particles with a 0,3µm diffusion diameter in accordance with 2.2 of ISO 7708:1995, with a minimum lead
content (typically less than 0,1µg Pb), and compatible with the selected sample preparation method.
NOTE See annex A for guidance on filter selection.
8.3 Sampling pumps with an adjustable flowrate and capable of maintaining the selected flowrate (between
1 l/min and 5 l/min for personal sampling pumps, and between 5 l/min and 400 l/min for high-volume sampling
pumps) to within ±5% of the nominal value throughout the sampling period (see 10.1.2).
NOTE A flow-stabilized pump may be required to maintain the flowrate within the specified limits.
For personal sampling the pumps shall be capable of being worn by the worker without impeding normal work
activity. Sampling pump flowmeters shall be calibrated using either a primary or secondary standard; if a secondary
standard is used, it shall be calibrated using a primary standard.
The pump should have, as a minimum, the following features:
— an automatic control that keeps the volumetric flowrate constant in the case of a changing back-pressure;
— either a malfunction indicator which, following completi
...

NORME ISO
INTERNATIONALE 8518
Deuxième édition
2001-12-15
Air des lieux de travail — Dosage du plomb
particulaire et des composés particulaires
du plomb — Méthode par spectrométrie
d'absorption atomique dans la flamme ou
méthode par spectrométrie d'absorption
avec atomisation électrothermique
Workplace air — Determination of particulate lead and lead compounds —
Flame or electrothermal atomic absorption spectrometric method

Numéro de référence
ISO 8518:2001(F)
©
ISO 2001

---------------------- Page: 1 ----------------------
ISO 8518:2001(F)
PDF — Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier peut
être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence autorisant
l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées acceptent de fait la
responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute responsabilité en la
matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info du
fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir l'exploitation de
ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation, veuillez en informer le
Secrétariat central à l'adresse donnée ci-dessous.
© ISO 2001
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de
l'ISO à l'adresse ci-après ou au comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56  CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.ch
Web www.iso.ch
Imprimé en Suisse
©
ii ISO 2001 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 8518:2001(F)
Sommaire Page
1 Domaine d'application . 1
2 Références normatives . 1
3 Termes et définitions . 2
4 Principe . 6
5 Réactions . 6
6 Exigence . 6
7 Réactifs . 7
8 Appareillage . 8
9 Évaluation de l'exposition professionnelle . 12
9.1 Stratégie de l'évaluation . 12
9.2 Stratégie de mesurage . 12
9.3 Sélection des conditions de mesurage et du mode de mesurage . 12
10 Échantillonnage . 13
10.1 Considérations préliminaires . 13
10.2 Préparation du matériel d'échantillonnage . 14
10.3 Point d'échantillonnage . 15
10.4 Collecte des échantillons . 15
10.5 Transport . 16
11 Analyse . 16
11.1 Nettoyage de la verrerie et des récipients en plastique . 16
11.2 Préparation des solutions d'échantillons et de blancs . 16
11.3 Analyse instrumentale . 18
11.4 Estimation de la limite de détection des instruments . 21
11.5 Estimation de la limite de détection de la méthode . 22
11.6 Contrôle qualité . 22
12 Expression des résultats . 23
12.1 Calcul . 23
12.2 Performances de la méthode . 23
13 Cas particuliers . 24
14 Rapport d'essai . 25
Annexes
A Recommandations pour le choix du filtre. 27
B Correction de la température et de la pression. 29
Bibliographie. 31
©
ISO 2001 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 8518:2001(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée aux
comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales, en liaison
avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec la Commission électrotechnique
internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI, Partie 3.
Les projets de Normes internationales adoptés par les comités techniques sont soumis aux comités membres pour
vote. Leur publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments de la présente Norme internationale peuvent faire l'objet
de droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne pas
avoir identifié de tels droits de propriété et averti de leur existence.
La Norme internationale ISO 8518 a été élaborée par le comité technique ISO/TC 146, Qualité de l'air, sous-comité
SC 2, Atmosphères des lieux de travail.
Cette deuxième édition annule et remplace la première édition (ISO 8518:1990), dont elle constitue une révision
technique.
Les annexes A et B de la présente Norme internationale sont données uniquement à titre d'information.
©
iv ISO 2001 – Tous droits réservés

---------------------- Page: 4 ----------------------
ISO 8518:2001(F)
Introduction
La santé des travailleurs dans de nombreuses industries (par exemple, l'industrie minière, le raffinage des métaux,
la fabrication de batteries, le bâtiment, etc.) est mise en danger du fait de l'exposition par inhalation de plomb
particulaire et de composés particulaires du plomb. Les hygiénistes industriels et autres professionnels de santé
publique ont besoin de déterminer l'efficacité des mesures prises pour contrôler l'exposition des travailleurs, et ceci
s'effectue en général en faisant des mesurages de l'air du lieu de travail. La présente Norme internationale fournit
une méthode permettant d'effectuer des mesurages d'exposition valables pour le plomb. Elle sera utile aux
organismes s'occupant d'hygiène et de sécurité du travail, aux hygiénistes industriels et autres professionnels de
santé publique, aux laboratoires d'analyses, aux industriels utilisateurs de métaux et métalloïdes et à leurs
employés, etc.
Lors de l'élaboration de la présente Norme internationale, il a été supposé que les personnes chargées de
l'exécution de ses dispositions et de l'interprétation des résultats obtenus possèdent les qualifications et l'expérience
appropriées.
©
ISO 2001 – Tous droits réservés v

---------------------- Page: 5 ----------------------
NORME INTERNATIONALE ISO 8518:2001(F)
Air des lieux de travail — Dosage du plomb particulaire et des
composés particulaires du plomb — Méthode par spectrométrie
d'absorption atomique dans la flamme ou méthode par
spectrométrie d'absorption avec atomisation électrothermique
1 Domaine d'application
1.1 La présente Norme internationale spécifie la méthode par spectrométrie d'absorption atomique dans la flamme
et la méthode par spectrométrie d’absorption avec atomisation électrothermique pour la détermination de la
concentration en masse moyenne pondérée dans le temps du plomb particulaire et des composés particulaires du
plomb présents dans l'air des lieux de travail.
1.2 La méthode est applicable à l'échantillonnage individuel de la fraction inhalable de particules en suspension
dans l'air, selon la définition de l’ISO 7708, et à l'échantillonnage (d'ambiance) à point fixe.
1.3 La méthode de mise en solution d'échantillons spécifie la digestion sur plaque chauffante ou par micro-ondes
ou l'extraction par ultrasons (11.2). L'utilisation d'une autre méthode de mise en solution plus énergique est
nécessaire lorsque le plomb doit être extrait de composés présents dans l'atmosphère d'essai non solubilisés par les
méthodes de mise en solution décrites dans la présente Norme internationale.
1.4 La méthode par spectrométrie d'absorption atomique dans la flamme est applicable au dosage de masses
d'environ 1µg à 200µg de plomb par échantillon, sans dilution [1]. La méthode par spectrométrie d'absorption avec
atomisation électrothermique est applicable au dosage de masses d'environ 0,01µg à 0,5µg de plomb par
échantillon, sans dilution [1].
1.5 Le mode opératoire d'extraction par ultrasons a été validé pour le dosage de masses d'environ 20µg à 100µg
de plomb par échantillon, pour des filtres échantillons obtenus en laboratoire par échantillonnage d'air après
génération de fumées de plomb [2].
1.6 L’étendue de concentration en plomb de l'air à laquelle ce mode opératoire est applicable est déterminée en
partie par le mode opératoire d'échantillonnage choisi par l'utilisateur (voir 10.1).
2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence qui y est faite,
constituent des dispositions valables pour la présente Norme internationale. Pour les références datées, les
amendements ultérieurs ou les révisions de ces publications ne s'appliquent pas. Toutefois, les parties prenantes
aux accords fondés sur la présente Norme internationale sont invitées à rechercher la possibilité d'appliquer les
éditions les plus récentes des documents normatifs indiqués ci-après. Pour les références non datées, la dernière
édition du document normatif en référence s'applique. Les membres de l'ISO et de la CEI possèdent le registre des
Normes internationales en vigueur.
ISO 648:1977, Verrerie de laboratoire — Pipettes à un trait
ISO 1042:1998, Verrerie de laboratoire — Fioles jaugées à un trait
ISO 3585:1998, Verre borosilicaté 3.3 — Propriétés
ISO 3696:1987, Eau pour laboratoire à usage analytique — Spécification et méthodes d'essai
©
ISO 2001 – Tous droits réservés 1

---------------------- Page: 6 ----------------------
ISO 8518:2001(F)
ISO 7708:1995, Qualité de l'air — Définitions des fractions de taille des particules pour l'échantillonnage lié aux
problèmes de santé
ISO 8655-1, Appareils volumétriques à piston — Partie 1: Définitions, exigences générales et recommandations
pour l'utilisateur
ISO 8655-2, Appareils volumétriques à piston — Partie 2: Pipettes à piston
ISO 8655-5, Appareils volumétriques à piston — Partie 5: Dispenseurs
ISO 8655-6, Appareils volumétriques à piston — Partie 6: Méthodes gravimétriques pour la détermination de l'erreur
de mesure
ISO 15202-2:2001, Air des lieux de travail — Détermination des métaux et métalloïdes dans les particules en
suspension dans l'air par spectrométrie d'émission atomique avec plasma à couplage inductif— Partie2:
Préparation des échantillons
1)
EN 13205 , Atmosphères des lieux de travail — Évaluation des performances des instruments de mesurage des
concentrations d'aérosols
3 Termes et définitions
Pour les besoins de la présente Norme internationale, les termes et définitions suivants s'appliquent.
3.1 Définitions générales
3.1.1
agent chimique
tout élément ou composé chimique, seul ou mélangé, tel qu'il se présente à l'état naturel ou tel qu'il est produit, utilisé
ou éliminé, y compris comme déchet, du fait d'une activité industrielle, qu'il soit ou non produit intentionnellement et
qu'il soit ou non commercialisé
[EN 1540]
3.1.2
zone respiratoire
volume autour de la face du travailleur dans lequel il ou elle respire
NOTE Une définition plus précise est utilisée à des fins techniques: hémisphère (généralement de rayon 0,3 m) s'étendant
devant la face de la personne, centrée sur le milieu du segment qui joint les deux oreilles et dont la base est le plan passant par
ce segment, le sommet de la tête et le larynx. Cette définition est inapplicable quand un équipement de protection respiratoire est
utilisé.
[EN 1540]
3.1.3
exposition par inhalation
situation dans laquelle un agent chimique est présent dans l'air inhalé par une personne
3.1.4
procédure de mesurage
mode opératoire pour l'échantillonnage et l'analyse d'un ou de plusieurs agents chimiques présents dans l'air, qui
comprend le stockage et le transport de l'échantillon
1) À publier.
©
2 ISO 2001 – Tous droits réservés

---------------------- Page: 7 ----------------------
ISO 8518:2001(F)
3.1.5
durée d'utilisation
période pendant laquelle une pompe d'échantillonnage peut être utilisée à un débit et avec une perte de charge
spécifiés sans recharger ni remplacer les batteries
[EN 1232]
3.1.6
concentration moyenne pondérée dans le temps
concentration d'un agent chimique dans l'atmosphère, en moyenne sur la période de référence
NOTE Une discussion plus détaillée sur les concentrations moyennes pondérées en temps et leur utilisation apparaît dans la
publication référencée sous [3] dans la bibliographie.
3.1.7
valeur limite
chiffre de référence pour la concentration d'un agent chimique dans l'air
®
EXAMPLE Valeur limite tolérable [Threshold Limit Value (TLV)] pour une matière donnée présente dans l'air des lieux de travail,
conformément à la définition de l'ACGIH [3].
3.1.8
période de référence
durée attachée à la définition de la valeur limite d'un agent chimique déterminé
NOTE Un exemple de valeur limite pour différentes périodes de référence sont les limites d'exposition à court et long terme,
conformément à la définition de l'ACGIH [3].
3.1.9
lieu de travail
l'endroit ou les endroits défini(s) où les activités du travail sont accomplies
[EN 1540]
3.2 Définitions des fractions de taille
3.2.1
convention inhalable
spécification-cible pour les instruments d'échantillonnage lorsque la fraction inhalable présente un intérêt
[ISO 7708]
3.2.2
fraction inhalable
fraction en masse du total des particules en suspension dans l'air qui est aspiré par le nez et la bouche
NOTE La fraction inhalable dépend de la vitesse et de la direction du mouvement de l'air, du rythme de la respiration et d'autres
facteurs.
[ISO 7708]
3.2.3
convention alvéolaire
spécification-cible pour les instruments d'échantillonnage lorsque la fraction alvéolaire présente un intérêt
[ISO 7708]
©
ISO 2001 – Tous droits réservés 3

---------------------- Page: 8 ----------------------
ISO 8518:2001(F)
3.2.4
fraction alvéolaire
fraction en masse des particules inhalées pénétrant dans les voies respiratoires non ciliées
[ISO 7708]
3.2.5
total des particules dans l'air
toutes les particules en suspension dans un volume donné d'air
NOTE Étant donné que tous les instruments de mesurage sélectionnent les dimensions jusqu'à un certain point, il est souvent
impossible de mesurer la concentration totale des particules en suspension dans l'air.
[ISO 7708]
3.3 Définitions relatives à l'échantillonnage
3.3.1
échantillonneur individuel
appareil fixé sur une personne qui échantillonne l'air dans sa zone respiratoire
[EN 1540]
3.3.2
échantillonnage individuel
processus d'échantillonnage exécuté en utilisant un échantillonneur individuel
[EN 1540]
3.3.3
instrument d'échantillonnage
échantillonneur
dispositif destiné à recueillir les particules en suspension dans l'air
NOTE Les instruments utilisés pour recueillir les particules en suspension dans l'air sont fréquemment désignés par d'autres
termes, tels que têtes de prélèvement, porte-filtre, cassettes de filtre, etc.
3.3.4
échantillonnage à point fixe
échantillonnage d'ambiance
processus d'échantillonnage de l'air exécuté à un emplacement particulier
3.3.5
échantillonneur à point fixe
échantillonneur d'ambiance
appareil utilisé pour effectuer un échantillonnage à point fixe, sans être fixé sur une personne
3.4 Définitions relatives à l'analyse
3.4.1
mise en solution d'échantillons
processus permettant d'obtenir une solution contenant les analytes étudiés à partir d'un échantillon
NOTE Ce processus peut ou non impliquer la mise en solution complète de l'échantillon.
3.4.2
préparation des échantillons
toutes les opérations effectuées sur un échantillon, après le transport et le stockage, pour le préparer à l'analyse, y
compris la transformation de l'échantillon en une forme mesurable si nécessaire
©
4 ISO 2001 – Tous droits réservés

---------------------- Page: 9 ----------------------
ISO 8518:2001(F)
3.4.3
solution d'échantillon
solution préparée au moyen du processus de mise en solution d'échantillons, mais devant éventuellement être
soumise à d'autres opérations afin de produire une solution d'essai prête pour l'analyse
3.4.4
solution d'essai
solution préparée au moyen du processus de mise en solution d'échantillons et, si besoin, ayant été soumise à
toutes les autres opérations nécessaires pour la rendre analysable
3.5 Termes statistiques
3.5.1
recouvrement analytique
rapport entre la masse d'analyte mesurée lors de l'analyse d'un échantillon et la masse connue d'analyte dans cet
échantillon
NOTE Le recouvrement analytique est exprimé en pourcentage.
3.5.2
erreur systématique
biais
écart systématique des résultats d'un processus de mesurage par rapport à la valeur vraie de la caractéristique de
la qualité de l'air elle-même
[ISO 6879]
3.5.3
incertitude globale
〈d’une procédure de mesurage ou d'un instrument〉 quantité utilisée pour caractériser dans son ensemble
l'incertitude du résultat indiqué par un appareil ou une procédure de mesurage
NOTE Elle s'exprime, en pourcentage, par une combinaison de l'erreur systématique et de la fidélité, en général conformément
à la formule suivante:
|x−x |+ 2s
ref
× 100
x
ref

xnest la valeur moyenne des résultats d’un nombre ( ) de mesurages répétés;
x est la valeur de référence vraie ou acceptée de concentration;
ref
s est la mesure de l'écart-type des mesurages répétés.
[EN 482]
3.5.4
fidélité
étroitesse de l'accord entre les résultats obtenus en appliquant la même méthode à plusieurs reprises, dans les
conditions stipulées
[ISO 6879]
NOTE La fidélité est souvent exprimée en termes d'écart-type relatif.
©
ISO 2001 – Tous droits réservés 5

---------------------- Page: 10 ----------------------
ISO 8518:2001(F)
3.5.5
valeur vraie
valeur qui caractérise une grandeur parfaitement définie, dans les conditions qui existent lorsque cette grandeur est
considérée
[ISO 3534-1]
NOTE La valeur vraie d'une grandeur est une notion théorique et, en général, ne peut pas être connue exactement (voir
l'EN 1540).
4Principe
4.1 Un volume défini d'air est prélevé à travers un filtre afin de recueillir du plomb particulaire et des composés
particulaires du plomb. L'échantillonnage individuel utilise un échantillonneur conçu pour recueillir la fraction
inhalable des particules en suspension dans l'air.
4.2 Le filtre et l'échantillon recueilli sont soumis à une méthode de mise en solution afin d'extraire le plomb. La
méthode de mise en solution de l'échantillon peut utiliser l’une des trois techniques suivantes: digestion sur plaque
chauffante, digestion par micro-ondes ou extraction par ultrasons.
4.3 Les solutions d'échantillons sont analysées pour déterminer leur teneur en plomb par aspiration des solutions
dans la flamme oxydante air-acétylène d'un spectromètre d'absorption atomique équipé d'une lampe à cathode
creuse en plomb ou d'une lampe à décharge sans électrode. L'absorbance est mesurée à 283,3 nm et les résultats
de l'analyse sont obtenus par la technique de la courbe analytique (voir 6.1 de l'ISO 6955:1982). Une éventuelle
interférence par des anions qui précipitent avec le plomb est éliminée par l'ajout de sel disodique d'acide éthylène-
diamino-tétra-acétique (EDTA) si nécessaire.
4.4 L'analyse peut être répétée par spectrométrie d'absorption avec atomisation électrothermique pour un dosage
du plomb précis lorsque la concentration en plomb dans la solution est faible. Les parties aliquotes de la solution
d'essai sont injectées dans un four à graphite et l'échantillon est atomisé électrothermiquement après séchage et
incinération de l'échantillon. L'absorbance est mesurée à 283,3 nm avec une correction de fond et les résultats sont
obtenus par la technique de la courbe analytique (voir 6.1 de l'ISO 6955:1982).
4.5 Les résultats peuvent être utilisés pour évaluer l'exposition sur les lieux de travail au plomb particulaire en
suspension dans l'air (voir l'EN 689).
5 Réactions
En général, la majorité des composés particulaires du plomb que l'on rencontre communément dans les échantillons
d'air de lieux de travail sont convertis, par les méthodes de mise en solution décrites en 11.2, en composés ioniques
2+
de plomb (Pb ) solubles dans l'eau. Cependant, il est possible que certains composés du plomb, par exemple le
silicate de plomb, ne se dissolvent pas. Si nécessaire, il convient d'utiliser une méthode de mise en solution utilisant
de l'acide fluorhydrique pour dissoudre le silicate de plomb. S'il existe le moindre doute concernant l'efficacité de ces
méthodes de mise en solution des composés particulaires du plomb susceptibles d'être présents dans l'atmosphère
d'essai, il est alors nécessaire d'étudier ce problème avant de poursuivre avec la méthode d’analyse décrite dans
l’article 11.
6 Exigence
La procédure de mesurage doit satisfaire à toute Norme internationale, européenne ou nationale correspondante qui
spécifie les exigences de performances relatives aux procédures de mesurage des agents chimiques présents dans
l'air des lieux de travail (par exemple EN 482).
©
6 ISO 2001 – Tous droits réservés

---------------------- Page: 11 ----------------------
ISO 8518:2001(F)
7 Réactifs
Lors de l'analyse, utiliser uniquement des réactifs de qualité analytique reconnue, et uniquement de l'eau telle que
spécifiée en 7.1.
7.1 Eau, conforme aux exigences pour une eau de qualité 2 selon l'ISO 3696 (conductivité électrique inférieure à

0,1 mS/m 0,01 MΩ·m25 C
et résistivité supérieure à à ).
La teneur en plomb de l’eau doit être inférieure à 0,01µg/ml.
Il est recommandé d'utiliser une eau provenant d'un système d'épuration d'eau qui fournit une eau ultrapure ayant
une résistivité supérieure à 0,18 MΩ·m (valeur habituellement exprimée par les fabricants de systèmes d'épuration
d'eau en 18 MΩ·cm).
7.2 Acide nitrique (HNO ), concentré, ρ ≈ 1,42 g/ml [environ 70 % (fraction massique)].
3
La teneur en plomb doit être inférieure à 0,01µg/ml.
AVERTISSEMENT — L'acide nitrique concentré est corrosif et oxydant et les fumées d'acide nitrique sont
irritantes. Éviter toute exposition par contact avec la peau ou les yeux, ou par inhalation de fumées. Utiliser
un équipement de protection individuelle (y compris gants appropriés, masque de protection ou lunettes de
sécurité, etc.) pour tout travail avec de l'acide nitrique concentré ou dilué, et effectuer la mise en solution
d'échantillons avec de l'acide nitrique concentré dans des récipients ouverts sous une hotte.
7.3 Acide nitrique, dilué 1+ 1.
Ajouter soigneusement 500 ml d'acide nitrique concentré (7.2) à 450 ml d'eau (7.1) dans un bécher de 2 l. Agiter en
tournant pour mélanger, laisser refroidir et verser dans une fiole jaugée à un trait de 1l (8.6.1.4). Diluer avec de l'eau
jusqu'au trait, boucher et mélanger énergiquement.
7.4 Acide nitrique, dilué 1+ 9.
Verser environ 800 ml d'eau (7.1) dans une fiole jaugée à un trait de 1 l (8.6.1.4). Ajouter soigneusement 100 ml
d'acide nitrique concentré (7.2) à la fiole et agiter en tournant pour mélanger. Laisser refroidir, diluer avec de l'eau
jusqu'à 1l et mélanger parfaitement.
7.5 Acide fluorhydrique (HF), concentré, ρ ≈ 1,16 g/ml [environ 48 % (fraction massique)], si nécessaire, pour
la digestion des échantillons contenant des silicates de plomb.
La teneur en plomb de l’acide fluorhydrique doit être inférieure à 0,1µg/ml.
AVERTISSEMENT — L'acide fluorhydrique concentré et la vapeur de fluorure d'hydrogène sont très toxiques
et fortement corrosifs; l'acide fluorhydrique dilué peut également entraîner de graves et douloureuses
brûlures qui peuvent n'être ressenties que 24 h après le contact. Éviter toute exposition par contact avec la
peau ou les yeux, ou par inhalation de vapeur. Il est essentiel d'utiliser un équipement de protection
individuelle (par exemple gants imperméables, masque de protection ou lunettes de sécurité, etc.) lors de
tout travail avec de l'acide fluorhydrique concentré ou dilué. Il convient d'utiliser l'acide fluorhydrique
concentré sous une hotte. Il est essentiel que les travailleurs aient à leur disposition le gel d'antidote à
l'acide fluorhydrique contenant du gluconate de calcium au cours de l'utilisation d'acide fluorhydrique et
pendant les 24 h suivantes.
7.6 Modifieur de matrice, NH H PO , Mg(NO ) ou Pd(NO ) , ou une combinaison de ces éléments, si
4 2 4 3 2 3 2
nécessaire, pour analyse par spectrométrie d'absorption avec atomisation électrothermique.
7.7 Solution mère de plomb, 1 000 mg/l de plomb.
Utiliser une solution étalon courante avec une teneur en plomb certifiée raccordable aux étalons nationaux.
Respecter la date d'expiration ou la durée de conservation recommandée par le fabricant.
©
ISO 2001 – Tous droits réservés 7

---------------------- Page: 12 ----------------------
ISO 8518:2001(F)
Alternativement, préparer une solution étalon de plomb à l'aide de l'un des modes opératoires suivants:
a) Dissoudre 1,598 g ± 0,001 g de nitrate de plomb(II) [Pb(NO ) ], préalablement séché à masse constante à
3 2

110 C et refroidi dans un dessiccateur, dans 200 ml d'acide nitrique 1+ 1 (7.3). Verser la solution dans une fiole
jaugée à un trait de 1 000 ml (8.6.1.4). Diluer avec de l'eau (7.1) jusqu'au trait, boucher et mélanger parfaitement.
Conserver dans un récipient approprié, par exemple une bouteille en polypropylène (8.6.2.2), pendant une durée
maximale d'un an.
b) Dissoudre 1,000 g+ 0,001 g de fil de plomb [99,9 % (fraction massique) Pb] dans 200 ml d'acide nitrique 1+ 1
1 000 ml
(7.3). Verser la solution dans une fiole jaugée à un trait de (8.6.1.4), diluer avec de l'eau (7.1) jusqu'au
trait, boucher et mélanger parfaitement. Conserver dans un récipient approprié, par exemple une bouteille en
polypropylène (8.6.2.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.