CEN/TC 129/WG 3 - Laminated glass
To produce a harmonised standard on laminated and laminated safety glass.
Laminated glass
To produce a harmonised standard on laminated and laminated safety glass.
General Information
This document specifies dimensions, limit deviations and edge finishes of laminated glass and laminated safety glass for use in building.
This document is not applicable to panes having an area less than 0,05 m2.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This document defines terms and describes component parts for laminated glass and laminated safety glass for use in building.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies defects of finished sizes and test methods with regard to the appearance of laminated glass and laminated safety glass when looking through the glass.
All references to laminated glass in this document refer to both laminated glass and laminated safety glass.
NOTE Special attention is paid to acceptability criteria in the vision area.
This document is applicable to finished sizes at the time of supply.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies performance requirements for laminated safety glass as defined in ISO 12543-1.
NOTE Any defects that are found in installed laminated safety glass are dealt with in ISO 12543-6.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies test methods relating to resistance to high temperature, humidity and radiation for laminated glass and laminated safety glass for use in building.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies performance requirements for laminated glass as defined in ISO 12543-1.
NOTE Any defects that are found in installed laminated safety glass are dealt with in ISO 12543-6.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers the evaluation of conformity and the factory production control of
- EN ISO 12543-2: Laminated safety glass;
- EN ISO 12543-3: Laminated glass;
inclusive laminated (safety) glass with fire resistant properties.
For glass products with electrical wiring or connections for e.g. alarm or heating purposes, this standard covers only wiring subject for electrical potential difference to earth less than 50 V a.c. or less than 75 V d.c.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
CMC - Editorial error, numbering of subclauses in A.3
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method for determining the mechanical viscoelastic properties of interlayer materials. The interlayers under examination are those used in the production of laminated glass or laminated safety glass. The shear characteristics of interlayers are needed to design laminated glass in accordance with EN 16612:2019 and prEN 19100 (all parts).
Parameters of the Prony series, widely used in numerical simulation, can be derived from the measurements in Annex C.
- Draft33 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the composition, tolerances and characteristics, i.e. mechanical, acoustic, optical and thermal properties, of folio interlayers for the manufacturing of laminated glass and laminated safety glass for use in buildings and construction works and it defines their general quality criteria.
This document does not apply to interlayers for laminated glass which are achieved by pouring the interlayer material in liquid state on or between the plies of glass or plastic glazing sheet material generally followed by drying or chemical or ultraviolet curing.
- Draft13 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers the assessment and verification of constancy of performances and the factory production control of laminated glass and laminated safety glass for use in buildings.
NOTE For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.
- Draft56 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 12543-6:2011 specifies defects of finished sizes and test methods with regard to the appearance of laminated glass when looking through the glass.
ISO 12543-6:2011 is applicable to finished sizes at the time of supply.
- Corrigendum5 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 12543-2:2011 specifies performance requirements for laminated safety glass as defined in ISO 12543-1.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 12543-5:2011 specifies dimensions, limit deviations and edge finishes of laminated glass and laminated safety glass for use in building.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 12543-4:2011 specifies test methods in respect of resistance to high temperature, humidity and radiation for laminated glass and laminated safety glass for use in building.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 12543-6:2011 specifies defects of finished sizes and test methods with regard to the appearance of laminated glass when looking through the glass.
ISO 12543-6:2011 is applicable to finished sizes at the time of supply.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 12543-1:2011 defines terms and describes component parts for laminated glass and laminated safety glass for use in building.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 12543-3:2011 specifies performance requirements for laminated glass as defined in ISO 12543-1.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 12543-2:2004 specifies performance requirements for laminated safety glass.
- Amendment4 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 12543-2:2004 specifies performance requirements for laminated safety glass.
- Standard6 pagesEnglish languagesale 10% offe-Library read for1 day
This part of this European Standard specifies dimensions, limit deviations, and edge finishes of laminated glass and laminated safety glass for use in building. It does not apply to panes having an area less than 0,05 m2.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This part of this European Standard specifies test methods in respect of resistance to high temperature, humidity and radiation for laminated glass and laminated safety glass for use in building.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This part of this European Standard defines terms and describes component parts for laminated glass and laminated safety glass for use in building.
- Standard7 pagesEnglish languagesale 10% offe-Library read for1 day
This part of this European Standard specifies defects of finished sizes and test methods with regard to the appearance when looking through the glass. Special attention is paid to acceptability criteria in the vision area. These criteria apply to products at the time of supply.
- Standard7 pagesEnglish languagesale 10% offe-Library read for1 day
This part of this European Standard specifies performance requirements for laminated glass as defined in prEN ISO 12543-1.
- Standard6 pagesEnglish languagesale 10% offe-Library read for1 day