This document specifies the test method, safety requirements and classification when determining the effect on a complete window or pedestrian doorset impacted with a soft and heavy body. Any secondary moving sashes, casements, leaves, mullions, transoms, T-connectors or fixed lights which can be mounted internally to the main casements or sashes, are intended to also be similarly tested and evaluated for the classification for the complete product.
The test applies to all types of infill of whatever materials including glass. It is not intended to classify the strength of the glass when used as an infill. It is intended to assess the interactions between all components of a window with particular regard to safety in use. It is also applicable to assess the ability of a doorset to keep in place glazed parts.
NOTE 1   The test method is aimed for glazed pedestrian doorsets with injury risk, but can also be used for other types of pedestrian doorsets if requested by the client.
NOTE 2   The test has been devised to suit all window or pedestrian doorset types, configurations and materials.
NOTE 3   For the classification of glass see EN 12600.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives the tolerance limits for specified dimensions of height, width and thickness, and for squareness of door leaves. It applies to door leaves which are supplied without, and independent of, any frames. It does not apply to the leaves of doorsets.
NOTE   Compliance with the tolerance limits given in this document does not imply that this would necessarily produce a perfect fit between door leaves and frames

  • Standard
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard identifies material independent performance characteristics, except resistance to fire and smoke control characteristics, which are applicable to internal pedestrian doorsets.
Fire resisting and/or smoke control characteristics for pedestrian doorsets and openable windows are covered by EN 16034.
This European Standard applies to doorsets intended to be used internally for construction works as:
-   intended use a) in escape routes;
-   intended use b) for specific uses with specific requirements;
-   intended use c) for communication only.
NOTE 1   These above intended uses can be combined, for example escape routes with specific requirements.
For internal pedestrian doorsets with resistance to fire and /or smoke control characteristics, this standard should only apply in conjunction with EN 16034.
Products covered by this European Standard are power operated hinged or manually operated internal pedestrian doorsets and screens with flush or panelled leaves, single or double leaf, which could be completed with:
-   related building hardware;
-   door closing devices;
-   integral fanlights;
-   adjacent parts that are contained within a single frame for inclusion in a single aperture.
NOTE 2   Manually operated doors with door closing devices are not considered to be power operated doors.
Products covered by this European Standard are not assessed for structural applications.
This European Standard does not apply to:
-   industrial, commercial and garage doors and gates according to EN 13241;
-   external pedestrian doorsets according to EN 14351-1;
-   door leaves placed on the market as a single unit;
-   door frames placed on the market as a single unit;
-   power operated pedestrian doorsets, other than swing type, according to EN 16361.
Doorsets can be placed on the market with their component (leaf and frame) separate when each of these components are clearly identified.
This European Standard does not deal with any specific requirements on noise emitted from internal power operated hinged doorsets as their noise emission is not considered to be a relevant hazard.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides a means of classifying the performance of opening windows according to their strength in resisting, where appropriate, racking load, static torsion and their manual operating forces. Special aspects such as those of burglar resistance are not covered. 1)
1) Effects on other criteria, such as air permeability, are not addressed by EN 13115.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the test method for determining the force required when engaging or releasing the hardware of a window and when commencing the movement of a casement or sash, in both opening and closing directions.
This document is applicable to all types of openable windows where the movement is a manual operation.
This document is applicable to products of any frame material.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides product category rules (PCR) for Type III environmental declarations for windows and pedestrian doorsets as defined in EN 14351-1 and EN 14351-2. Windows and pedestrian doorsets additionally providing fire resistance and/or smoke control characteristics according to EN 16034 are also covered by this document.
NOTE 1   Windows that incorporate shutters and/or shutter boxes and/or blinds are in scope of this PCR. For any connected electrical devices (e.g. motors, sensors) -see 6.3.4.2.
This document complements the core rules for the product category of construction products as defined in the European standard EN 15804:2012+A1:2013. The document is to be used in conjunction with EN 15804:2012+A1:2013, not replace it.
NOTE 2   The assessment of social and economic performances at product level is not covered by this document.
The core PCR:
-   defines the parameters to be declared and the way in which they are collated and reported;
-   describes which stages of a product’s life cycle are considered in the EPD and which processes are to be included in the life cycle stages;
-   defines rules for the development of scenarios;
-   includes the rules for calculating the Life Cycle Inventory and the Life Cycle Impact Assessment underlying the EPD, including the specification of the data quality to be applied;
-   includes the rules for reporting the predetermined, environmental and health information that is not covered by Life Cycle Assessment (LCA) for the product, construction process(es) and construction service(s), as relevant;
-   defines the conditions under which construction products can be compared based on the information provided by EPD.
For the EPD of construction services the same rules and requirements apply as for the EPD of construction products.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies general terminology for windows and pedestrian doors. The various terms are illustrated with the aid of figures.

  • Standard
    114 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard identifies material independent performance characteristics, except resistance to fire and smoke control characteristics, that are applicable to windows (including roof windows, roof windows with external fire resistance and door height windows), external pedestrian doorsets (and their assemblies, including unframed glass doorsets, escape route doorsets) and screens.
Fire resisting and/or smoke control characteristics for pedestrian doorsets and openable windows are covered by EN 16034.
This European Standard applies to:
a)   fixed windows or fixed lights, manually or power operated windows and door height windows, and screens for installation in vertical wall apertures and roof windows for installation in roofs, complete with:
1)   related hardware, if any;
2)   weather stripping, if any;
3)   glazed apertures when intended to have glazed apertures;
4)   with or without incorporated shutters and/or shutter boxes and/or blinds;
and manually or power operated windows, roof windows, door height windows and screens that are:
5)   fully or partially glazed including any non-transparent infill;
6)   fixed or partly fixed or openable with one or more casements/sashes (e.g. hinged, projecting, pivoted, sliding);
b)   manually operated external pedestrian doorsets with flush or panelled leaves, complete with:
1)   integral fanlights, if any;
2)   adjacent parts that are contained within a single frame for inclusion in a single aperture, if any.
The windows covered by this standard are not assessed regarding their ability to release (to open).
The products covered by this European Standard are not assessed for structural applications.
This European Standard does not apply to:
-   rooflights according to EN 1873 and EN 14963;
-   curtain walling according to EN 13830;
-   industrial, commercial and garage doors and gates according to EN 13241;
-   internal pedestrian doorsets according to prEN 14351 2;
-   revolving doorsets;
-   power operated pedestrian doorsets according to EN 16361;
-   windows intended to be part of internal partition.

  • Standard
    76 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    72 pages
    German language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the classification of test results for completely assembled windows and external and internal pedestrian doorsets of any materials after testing in accordance with EN 1026.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the test method to be used to determine the air permeability of completely assembled windows and doorsets of any material, when submitted to positive or negative test pressures. This test method is designed to take account of conditions in use, when the window or doorset is installed in accordance with the manufacturer’s specification and the requirements of relevant European Standards and codes of practice.
This European Standard does not apply to the joints between the window or doorset frame and the building construction.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the test method to determine the resistance to wind load for completely assembled windows and pedestrian doorsets of any materials when submitted to positive or negative test pressures.
This test method is designed to take account of conditions in use, when the window or door is installed in accordance with the manufacture's specification and the requirements of relevant European Standards and codes of practice.
This European Standard does not apply to joints between the window or door frame and the building construction.
This standard is not intended to evaluate strength of the glass.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the test method to be used to determine the watertightness of completely assembled windows and doorsets of any materials. This test method is designed to take account of conditions in use, when the window or doorset is installed in accordance with the manufacturer’s specification and the requirements of relevant European Standards and codes of practice.
This European Standard does not apply to the joints between the window or doorset frame and the building construction.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the classification of test results for completely assembled windows and doors of any materials after testing in accordance with EN 12211.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard identifies the performance characteristic that is applicable to door leaves for pedestrian doors, independent of the material, that are exposed to extended periods of wetness and/or frequent splash water.
NOTE   Rain is not considered as “frequent splash water” condition.
This European Standard does not apply to:
-   door leaves exposed to liquid having a pH value lower than 5.5 or higher than 8.5;
-   door frames, complete door assemblies or doorsets.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard is applicable to hinged/pivoted and sliding doorsets with latches, for pedestrian use. It defines the classification of the test results for the forces and/or torques to open/close doors and to engage/release and lock/unlock the hardware using a key or handle, after testing in accordance with EN 12046 2.
It is only applicable to the manual operation of doorsets.
The classification of forces for doorsets with self-closing devices engaged is excluded from this test method. It is also not applicable to doorsets with special hardware, e.g. emergency exit devices.
The tests are applicable to doorsets of any material.
The operation of some glazed doors (door high windows) involves hardware with latches and may be classified in accordance with this European Standard.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the method to be used to determine the resistance to repeated opening and closing of windows and pedestrian doorsets when subjected to repeated opening and closing.
It applies to all construction materials and operating systems for any window or pedestrian doorset, including gaskets and building hardware, in normal operating conditions.
The parts concerned in the testing are the frame, the opening component (including any additional moving components e.g. an inactive sash/leaf) and all essential and directly involved building hardware, including operating devices, for example, the handle.
The testing does not include any hardware whose operation is not directly involved in the opening and closing of the moving components: added-on fastening systems such as peg-stays or cabin hooks or bolts, nor, unless specified, any independently installed stops (not connected to the complete assembly) such as a wall or ground-mounted stop.
NOTE 1   The Annexes provide more details on the testing procedures that may differ from the main part of this European Standard and are mandatory:
-   Annex A applies to Tilt and Turn, Tilt-First, Turn-Only, or Tilt-Only windows and door-height windows;
-   Annex B applies to Sliding, Lift and Slide or Lift and Slide and Tilt windows and door-height windows;
-   Annex C applies to Tilt and Slide windows and door-height windows;
-   Annex D applies to Fold and Slide windows and door-height windows;
-   Annex E applies to horizontal and vertical pivot windows and door-height windows;
-   Annex F applies to Vertical Sliding windows;
-   Annex G applies to side-hung casements and top-hung windows, opening outwards (including reversible windows);
-   Annex H applies to side-hung single swing pedestrian doorsets excluding power operated doors;
-   Annex I applies to power-operated (automatic) side-hung single-swing pedestrian doorsets.
NOTE 2   In this European Standard the term door-height window is used for windows that are used for the passage of pedestrians, i.e. as a pedestrian doorset.

  • Standard
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the test methods for evaluating:
-   the risks of decay of openable and fixed windows manufactured of different materials through increased moisture accumulation as a result of condensation or water vapour diffusion;
-   the influence of deformation on basic performances of openable and fixed windows manufactured of different materials exposed to different climates between their external and internal faces.
Three test methods are to be differentiated. They take into account different cases of loadings.
-   Test method 1: For designs with low resistance to water vapour diffusion (normally designs with water vapour equalization holes); the test procedure is to be used for cross-sections where the danger is given by the moisture accumulation as a result of the condensation of moisture between the planking and the timber (see Annex A (informative), Figure A.1).
-   Test method 2.1 and 2.2: For designs with high resistance to water vapour diffusion (normally designs without water vapour equalization holes); the test procedure is to be used for cross-sections where the danger is given by the condensation of the moisture between the surface of the inner profile and the inner surface of the outer profile by having a different water vapour diffusion (see Annex A (informative), Figures A.2 and A.3).
-   Test method 3: For designs being sensitive to deformation; the test procedure is to be used for cross-sections where they are sensitive to the function through deformation as a result of climatic loading.
This European Standard defines the test procedures which are to be used in dependence of the potential risk of the design.
This European Standard is relevant to initial type testing, i. e. to developments or changes in designs. It is not relevant to routine quality control or to proven designs.
NOTE   Designs are included in Annex A (informative). Annex B (normative) is the survey of general design criteria where tests are not necessary.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the determination of permanent deformation caused by a static load applied to an open casement.
This European Standard applies to the opening modes specified in Figure A.1 to Figure A.5 and included in prEN 12519.
This test is not applicable to the sashes of sliding windows.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the determination of resistance to racking of an open casement or sash
expressed as loads and the resulting maximum and residual deformations.
This European Standard applies to the opening modes specified in Figure A.1 to Figure A.6 and included in
EN 12519.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard provides a means of classifying windows and doors according to their performance when subjected to repeated opening and closing. The performance levels take into account normal and intended use.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the criteria which windows, doors and shutters shall satisfy to achieve a classification when submitted to the test method described in EN 13124-1.
This European Standard concerns a method of test against blast waves generated by using a shock tube facility to simulate a high explosive detonation in the order of 100 kg to 2 500 kg TNT at distances from about 35 m to 50 m.
This European Standard is applicable to blast overpressure generated in a shock tube test facility used to simulate a high explosive detonation on windows, doors and shutters, complete with their frames and infills, for use in both internal and external locations in buildings. It gives no information on the explosion resistance capacity of the wall or other surrounding structure.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a conventional test procedure to permit classification of the explosion resistance of windows, doors and shutter together with their infills.
This European Standard concerns a method of test against blast waves generated by using a shock tube facility to simulate a high explosive detonation in the order of 100 kg to 2 500 kg TNT at distances from about 35 m to 50 m .
This European Standard covers only the behaviour of the complete unit including infill, frame and fixings as tested. It gives no information on the ability of the surrounding wall or building structure to resist the direct or transmitted forces.
If the windows, doors and shutters are intended for specific conditions of climate, specific test conditions may be required.
It gives no information on the behaviour of the units subjected to other types of loading.
NOTE   Care should be taken to ensure that all joints between the wall and the window or door have protection which is at least equal to that of the window or door.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standards defines the classification of test results for completely assembled windows and doors of any after testing in accordance with prEN 1027 "Windows and doors - Watertightness - Test method".

  • Standard
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements and classification that windows, doors, shutters and blinds must satisfy when tested in accordance with prEN 1523.  This standard is applicable to attacks by hand guns, rifles and shotguns on windows, doors, shutters and blinds complete with their frames and infills, for use in both internal an external locations in buildings. Shutters and blinds should be tested separately and not in conjunction with a window or door, in order to achieve classification in terms of bullet resistance.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a test procedure to permit classification of the bullet resistance of windows, doors, shutters and blinds (complete with their infills).  This European Standard concerns only behavior in respect of the frame of the windows, doors, shutters or blind, their infills and the junctions between the infills and frames.  If the windows and doors are subjected to specific conditions of climate, specific conditions of test may be required. It does not apply to the testing of glass infills. For the testing of glass infills refer to prEN 1063.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the criteria, which windows, doors, shutters as well as curtain walling elements need to satisfy to achieve a classification when submitted to the test method described in prEN 13124-2:2023.
This document concerns a method of test against blast waves produced by high explosives in an arena test. This document considers free-field high explosive events equivalent to:
-   3 kg to 20 kg (TNT equivalent) at distances from 3 m to 9 m, described by the fixed classification levels PXR 1 to PXR 7;
-   100 kg to 500 kg (TNT equivalent) at distances from about 15 m to 30 m, described by the fixed classification levels VXR 1 to VXR 7.
It produces a classification according to prEN 13124 2:2023. Indicative charge sizes and stand-off distances producing these loading levels are shown in Annex B.
Blast loadings characterised by user specified blast parameters for other high explosive scenarios can also be specified.
Blast loads which cannot be produced in an arena test might be produced by a shock tube test following prEN 13123-1:2022 and prEN 13124-1:2022.
This document is applicable to blast waves generated by explosives in an arena test facility to produce high explosive blast loads on windows, doors and shutters as well as curtain walling systems, complete with their frames, infills and fixings, for use in both internal and external locations in buildings. It gives no information on the explosion resistance capacity of the wall or other surrounding structure.

  • Draft
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a conventional test procedure to permit classification of the explosion resistance of windows, doors, shutters, together with their infills, as well as curtain walling elements.
This document concerns a method of test against blast waves produced by high explosives in an arena test. The loading categories are defined by pressure and impulse parameters and represent free-field high explosive events caused by:
-   3 kg to 20 kg (TNT equivalent) at stand-off distances from 3 m to 9 m, described by the fixed loading levels PXR 1 to PXR 7;
-   100 kg to 500 kg (TNT equivalent) at stand-off distances from about 15 m to 30 m, described by the fixed loading levels VXR 1 to VXR 7.
It produces a classification according to prEN 13123-2:2023.
Scenarios characterized by specified blast parameters for other high explosive scenarios, can also be specified.
Blast loads which cannot be produced in an arena test might be produced by a shock tube test following prEN 13123-1:2022 and prEN 13124-1:2022.
This document is applicable to blast waves generated by explosions in an arena test facility to produce high explosive blast loads on windows, doors and shutters as well as curtain walling systems, complete with their frames, infills and fixings, for use in both internal and external locations in buildings. It gives no information on the explosion resistance capacity of the wall or other surrounding structure.
This document covers only the behaviour of the complete test specimen including infill, frame and fixings as tested. It gives no information on the ability of the surrounding wall or building structure to resist the direct or transmitted forces.
If the windows, doors, shutters and curtain walling components are intended for specific conditions of climate, specific test conditions can be required.
Requirements for the performance of opening and locking mechanisms or for testing in an open condition can also be specified. It gives no information on the behaviour of the test specimens subjected to other types of loading.

  • Draft
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides product category rules (PCR) for Type III environmental declarations for windows and pedestrian doorsets as defined in EN 14351-1 and EN 14351-2. Windows and pedestrian doorsets additionally providing fire resistance and/or smoke control characteristics according to EN 16034 are also covered by this document.
NOTE 1   Windows that incorporate shutters and/or shutter boxes and/or blinds are in scope of this PCR. For any connected electrical devices (e.g. motors, sensors) -see 6.3.4.2.
This document complements the core rules for the product category of construction products as defined in the European standard EN 15804:2012+A1:2013. The document is to be used in conjunction with EN 15804:2012+A1:2013, not replace it.
NOTE 2   The assessment of social and economic performances at product level is not covered by this document.
The core PCR:
-   defines the parameters to be declared and the way in which they are collated and reported;
-   describes which stages of a product’s life cycle are considered in the EPD and which processes are to be included in the life cycle stages;
-   defines rules for the development of scenarios;
-   includes the rules for calculating the Life Cycle Inventory and the Life Cycle Impact Assessment underlying the EPD, including the specification of the data quality to be applied;
-   includes the rules for reporting the predetermined, environmental and health information that is not covered by Life Cycle Assessment (LCA) for the product, construction process(es) and construction service(s), as relevant;
-   defines the conditions under which construction products can be compared based on the information provided by EPD.
For the EPD of construction services the same rules and requirements apply as for the EPD of construction products.

  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the criteria, which windows, doors, shutters as well as curtain walling elements need to satisfy to achieve a classification when submitted to the test method described in prEN 13124 1:2022.
This document concerns a method of test against blast waves generated by using a shock tube facility to simulate explosion loadings. The document considers free-field high explosive events in the order of 100 kg to 2 500 kg TNT at distances from about 35 m to 50 m, described by the fixed loading levels EPR0 to EPR4. Scenarios characterized by variable blast parameters for further high explosive and gas explosion scenarios, reaching a classification according to prEN 13124 1:2022, can also be specified.
Load profiles which cannot be reproduced with the shock tube might be reproduced by arena testing following EN 13123 2 and EN 13124 2.
This document is applicable to blast profiles generated in a shock tube test facility used to simulate high explosive and gas explosions on windows, doors, shutters as well as curtain walling systems, complete with their frames, infills and fixings, for use in both internal and external locations in buildings. It gives no information on the explosion resistance capacity of the wall or other surrounding structure.

  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a conventional test procedure to permit classification of the explosion resistance of windows, doors, shutters, together with their infills, as well as curtain walling elements.
This document concerns a method of test against blast waves generated using a shock tube facility to simulate detonation events. This document considers high explosive detonations in the order of 100 kg to 2 500 kg TNT equivalent at distances from about 35 m to 50 m, described by the fixed loading levels EPR0 to EPR4. Scenarios characterized by variable blast parameters for further high explosive detonations and gas or chemical explosions can also be specified.
This document covers only the behaviour of the complete test specimen including infill, frame and fixings as tested.
This document gives no information on the ability of the surrounding wall or building structure to resist the direct or transmitted forces.
If the windows, doors, shutters and curtain walling components are intended for specific conditions of climate, specific test conditions can be required.
Requirements for the performance of opening and locking mechanisms or for testing in an open condition can also be specified.
This document gives no information on the behaviour of the test specimens subjected to other types of loading.

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is for hinged/pivoted and sliding doorsets with engaging fasteners (e.g. latches, deadbolts) for pedestrian use.
This document defines the test methods to determine the forces to open/close doors and to engage/release and lock/unlock the hardware using a key or handle.
It is only applicable to the manual operation of doorsets.
These doorsets may include emergency or panic exit devices.
The method of measuring the operating forces for pedestrian doorsets with self closing devices engaged are included in this test standard.
NOTE   The use of some windows involves engaging fasteners (e.g. latches, deadbolts) and may be tested in accordance with this standard.

  • Draft
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document identifies material independent performance characteristics, except resistance to fire and smoke control characteristics, that are applicable to windows (including roof windows, roof windows with external fire resistance and door height windows), external pedestrian doorsets (including unframed glass doorsets, escape route doorsets and their assemblies).
Fire resisting and/or smoke control characteristics for pedestrian doorsets and openable windows are covered by EN 16034.
This document applies to
-   fixed windows or fixed lights, manually or power operated windows, French windows and screens for installation in vertical wall apertures and roof windows for installation in inclined roofs, complete with:
-   related hardware, if any;
-   weather stripping, if any;
-   glazed apertures when intended to have glazed apertures;
-   with or without incorporated shutters and/or shutter boxes and/or blinds;
and manually or power operated windows, roof windows, French windows and screens that are:
-   fully or partially glazed including any non-transparent infill;
-   fixed or partly fixed or openable with one or more casements/sashes (e.g. hinged, projecting, pivoted, sliding);
-   manually operated external pedestrian doorsets or power operated external pedestrian hinged doorsets with flush or panelled leaves in construction works, complete with:
-   integral fanlights, if any;
-   adjacent parts that are contained within a single frame for inclusion in a single aperture, if any.
The windows covered by this document are not assessed regarding their ability to release (to open).
The products covered by this document are not assessed for structural applications.
This document does not apply to:
-   rooflights according to EN 1873 and EN 14963;
-   curtain walling according to EN 13830;
-   industrial, commercial and garage doors and gates according to EN 13241;
-   internal pedestrian doorsets according to EN 14351-2;
-   revolving doorsets;
-   power operated pedestrian doorsets according to EN 16361;
-   windows intended to be part of internal partition.

  • Draft
    91 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard is applicable to hinged/pivoted and sliding doorsets with latches, for pedestrian use. It defines the classification of the test results for the forces to open/close doors and to engage/release and lock/unlock the hardware using a key or handle, after testing in accordance with EN 12046-2.
It is only applicable to the manual operation of doorsets.
The measurement of forces for doorsets with self closing devices engaged is excluded from this test method. It is also not applicable to doorsets with special hardware e.g. emergency exit devices.
The tests are applicable to doorsets of any material.
The operation of some glazed doors, (door high windows) involves hardware with latches and may be classified in accordance with this standard.

  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard identifies material independent performance characteristics that are applicable to internal pedestrian doorsets.
This document applies to:
- Manually internal pedestrian doorsets and screens with flush or panelled leaves, complete with:
     - related hardware,
     - integral fanlights, if any,
     - adjacent parts that are contained within a single frame for inclusion in a single aperture, if any.
The products covered by this document are not assessed for structural applications.
This document does not apply to:
- Internal pedestrian doorsets subject to regulations on smoke leakage and resistance to fire according to prEN 14351-3 but individual characteristics and performance requirements given in clause 4 can be relevant for these internal doors (see prEN 14351-3);
- industrial, commercial and garage doors and gates according to EN 13241-1 and prEN 13241-2;
- external pedestrian doorsets according to EN 14351-1;
- revolving internal pedestrian doorsets,
- door leaves placed on the market separately.

  • Draft
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard identifies material independent performance characteristics that are applicable to windows (including roof windows, roof windows with external fire resistance and French windows), external pedestrian doorsets (including unframed glass doorsets, escape route doorsets) and screens.
This European Standard applies to:
-   Manually or power operated windows, French windows and screens for installation in vertical wall aper-tures and roof windows for installation in inclined roofs, complete with:
-   related hardware, if any;
-   weather stripping, if any;
-   glazed apertures when intended to have glazed apertures;
-   with or without incorporated shutters and/or shutterboxes and/or blinds;
and manually or power operated windows, roof windows, French windows and screens that are
-   fully or partially glazed including any non-transparent infill;
-   fixed or partly fixed or openable with one or more casements/sashes (e.g. hinged, projecting, pivoted, sliding).
-   Manually operated external pedestrian doorsets with flush or panelled leaves, complete with:
-   integral fanlights, if any;
-   adjacent parts that are contained within a single frame for inclusion in a single aperture, if any.
The products covered by this European Standard are not assessed for structural applications.
This European Standard does not apply to:
-   windows and pedestrian doorsets subject to regulations on smoke leakage and resistance to fire according to prEN 14351-3 but individual characteristics and performance requirements given in clause 4 can be relevant for these doors and windows (see prEN 14351-3);
-   rooflights according to EN 1873 and prEN 14963;
-   curtain walling according to EN 13830;
-   industrial, commercial and garage doors and gates according to EN 13241-1;
-   internal pedestrian doorsets according to prEN 14351-2 but individual characteristics and performance re-quirements given in clause 4 can be relevant for internal doors (see prEN 14351-2);
(....)

  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard identifies material independent performance characteristics that are applicable to windows (including roof windows, roof windows with external fire resistance and French windows), external pedestrian doorsets (including unframed glass doorsets, escape route doorsets) and screens. This European Standard applies to
:Manually or power operated windows, French windows and screens for installation in vertical wall apertures and roof windows for installation in inclined roofs, complete with:
· related hardware, if any;
· weather stripping, if any;
· glazed apertures when intended to have glazed apertures;
· with or without incorporated shutters and/or shutterboxes and/or blinds;and manually or power operated windows, roof windows, French windows and screens that are
· fully or partially glazed including any non-transparent infill;
· fixed or partly fixed or openable with one or more casements/sashes (e.g. hinged, projecting, pivoted, sliding).
- Manually or power operated external pedestrian doorsets with flush or panelled leaves, complete with:
· integral fanlights, if any;
· adjacent parts that are contained within a single frame for inclusion in a single aperture, if any.The products covered by this European Standard are not assessed for structural applications.

  • Draft
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Standard defines the method of test, requirements and classification when determining the effect on a window impacted with a soft and heavy body. Any secondary moving sashes casements or fixed lights which may be mounted internally to the main casements or sashes, shall also be similarly tested. The test applies to all infillings of whatever materials including glass. The test has been devised to suit all window types, configurations and materials.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard provides a means of classifying the performance of opening windows according to their strength in resisting, where appropriate, racking load, static torsion and their operating forces. Special aspects such as those of burglar resistance are not covered.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the test method for determining the force required when engaging or releasing the hardware of a window and when commencing the movement of a casement or sash, in both opening and closing directions.
It is applicable to manually operated windows.
This European Standard is applicable to products of any materials.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies a method for exposing test pieces from an unplasticized polyvinylchloride (PVC-U) profile for the fabrication of windows and doors to a Xenon arc laboratory light source, in order to assess changes in impact strength and colour. The method given in 8.10 (b) is the reference method of colour measurement.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the general terminology for windows and pedestrian doors. The various types are illustrated by figures.

  • Standard
    49 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of the heat reversion of unplasticized polyvinylchloride (PVC-U) profiles for the fabrication of windows and doors by a test at 100°C in an oven.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies two methods for the determination of the effectof heat on polyvinylchloride (PVC-U) profiles for the fabrication of windows anddoors. The oven method is considered as the reference method.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard defines the classification of test results for completely assembled windows and doors of any materials after testing in accordance with prEN 1026.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard identifies material independent performance characteristics that are applicable to win-dows (including roof windows, roof windows with external fire resistance and French windows), external pedestrian doorsets (including unframed glass doorsets, escape route doorsets) and screens.
This European Standard applies to:
-   Manually or power operated windows, French windows and screens for installation in vertical wall aper-tures and roof windows for installation in inclined roofs, complete with:
-   related hardware, if any;
-   weather stripping, if any;
-   glazed apertures when intended to have glazed apertures;
-   with or without incorporated shutters and/or shutterboxes and/or blinds;
and manually or power operated windows, roof windows, French windows and screens that are
-   fully or partially glazed including any non-transparent infill;
-   fixed or partly fixed or openable with one or more casements/sashes (e.g. hinged, projecting, pivoted, sliding).
-   Manually operated external pedestrian doorsets with flush or panelled leaves, complete with:
-   integral fanlights, if any;
-   adjacent parts that are contained within a single frame for inclusion in a single aperture, if any.
The products covered by this European Standard are not assessed for structural applications.
This European Standard does not apply to:
-   windows and pedestrian doorsets subject to regulations on smoke leakage and resistance to fire according to prEN 14351-3 but individual characteristics and performance requirements given in clause 4 can be relevant for these doors and windows (see prEN 14351-3);
-   rooflights according to EN 1873 and prEN 14963;
-   curtain walling according to EN 13830;
-   industrial, commercial and garage doors and gates according to EN 13241-1;
-   internal pedestrian doorsets according to prEN 14351-2 but individual characteristics and performance re-quirements given in clause 4 can be relevant for internal doors (see prEN 14351-2);
-   revolvin

  • Standard
    71 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard defines the conventional method to be used to determine the watertightness of completely assembled windows and doors of any materials. This test method is designed to take account of conditions in use, when the windows or door is installed in accordance with the manufacturer's specification and the requirements of relevant european standards and codes of pratice. This standard does not apply to the joints between the window and door frame and the building construction.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard defines the conventional method to be used to determine the air permeability of completely assembled windows and doors of any materials, when submitted to positive or negative test pressures. This test method is designed to take account of conditions in use, when the window or door is installed in accordance with the manufacturer's specification and the requirements of relevant European Standards and codes of practice. This standard does not apply to the joints between the window or door frame and the building construction.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard defines the method of test to determine the resistance to wind load for completely assembled windows and doors of any materials when submitted to positive and negative test pressures. This test method is designed to take account of conditions in use, when the window or door is installed in accordance with the manufactures specification and the requirements of relevant European Standard and codes of pratice. This Standard does not apply to joints between the window or door frame and the building construction. This Standard is not intended to evaluate strength of the glass.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard defines the classification of test results for completely assembled windows and doors of any materials after testing in accordance with prEN 12211 "Windows and doors - Resistance to wind load - Test Method".

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard specifies classifications, requirements and test methods for unplasticized polyvinylchloride (PVC-U) profiles for the fabricationof windows. Profiles in accordance with this standard are capable of making satisfactory and durable windows, taking into account factors such as climatic conditions, design, methods of fabrication and long term performance.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day