IEC/SC 36A - IEC_SC_36A
Standardization of insulated bushings, and of couplings of these insulators.
IEC_SC_36A
Standardization of insulated bushings, and of couplings of these insulators.
General Information
NEW!IEC 60137:2017 is available as IEC 60137:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60137:2017 specifies the characteristics and tests for insulated bushings. This standard is applicable to bushings, as defined in Clause 3, intended for use in electrical apparatus, machinery, transformers, switchgear and installations for three-phase alternating current systems, having highest voltage for equipment above 1 000 V and power frequencies of 15 Hz up to and including 60 Hz. Subject to special agreement between purchaser and supplier, this standard may be applied, in part or as a whole, to the following: - bushings used in other than three-phase systems; - bushings for high-voltage direct current systems; - bushings for testing transformers; - bushings for capacitors. Special requirements and tests for transformer bushings in this standard apply also to reactor bushings. This standard is applicable to bushings made and sold separately. Bushings which are a part of an apparatus and which cannot be tested according to this standard should be tested with the apparatus of which they form part. This edition includes the following significant technical changes with respect to the previous edition: - Resin-impregnated synthetic (RIS) bushings has been introduced. - Bushings with Um ≤ 1,1 kV, Um = 1100 kV and Um = 1200 kV have been introduced. - Temperature rise testing has been included for liquid-insulated bushings according to clause to 3.4. - Introducing dry lightning impulse testing as a routine test for all transformer bushings with Um > 72,5 kV. - The altitude correction procedure has been revised ( > 1 000 m). - An explanation about Very Fast Transient (VFT) phenomenon and its impact on bushings has been included.
- Standard64 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to ceramic and resin insulated bushings having highest voltages above 1 kV up to 52 kV, rated currents from 250 A up to 3 150 A and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers. This European Standard establishes essential dimensions, to ensure interchangeability of bushings and to ensure adequate mounting and interchangeability of mating plug-in separable connectors of equivalent ratings.
- Standard39 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to ceramic insulated bushings for rated voltages up to 1 000 V, rated currents from 250 A up to 5 000 A and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers. NOTE These bushings are suitable for operation at 1,1 kV in compliance with EN 50464-1.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation10 pagesSlovenian languagesale 10% offe-Library read for1 day
This European Standard is applicable to insulated bushings for maximum voltages above 1 kV up to 52 kV, rated currents from 250 A up to 2 500 A and frequencies from 15 Hz up to 60 Hz for equipment other than liquid filled transformers. This European Standard establishes essential dimensions, to ensure adequate mounting and interchangeability of mating plug-in separable connectors of equivalent ratings.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Specification is applicable to capacitance graded outdoor bushings with values of highest voltage for equipment (Um) from 52 kV up to 420 kV and with values of rated current (Ir) up to 3 150 A and frequencies from 15 Hz up to 60 Hz for oil immersed transformers. The major insulation of these bushings consists either of oil-impregnated or resin-impregnated paper or other suitable insulating systems. This Technical Specification establishes essential details and dimensions to ensure interchange ability and adequate mounting of the bushings.
- Technical specification19 pagesEnglish languagesale 10% offe-Library read for1 day
This standard is applicable to moulded indoor busbar bushings for rated voltages up to 1 000 V, rated currents from 1 250 A up to 5 000 A and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers. NOTE These bushings are suitable for operation at 1,1 kV in compliance with HD 428.1 S1.
- Standard6 pagesEnglish languagesale 10% offe-Library read for1 day
This standard is applicable to ceramic insulated outdoor bushings for highest voltages for equipment of 24 kV and 36 kV, with rated currents of 5 kA and 8 kA and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers. This standard establishes dimensions to ensure interchangeability and adequate mounting of bushings. Two types of construction are specified, type A and type B, both types for highest voltages for equipment 24 kV and 36 kV and rated currents of 5 kA and 8 kA. The mechanical stresses of the conductor tube make the difference between type A and type B. The conductor tube of type A is axially and radially fixed in the top of the bushing. The inner line terminal of the transformer can be flexible and without any special support for the lower end of the conductor tube. In case of type B, the conductor tube is only radially fixed in the top of the bushing. In that case, a rigid support has to be mounted to fix the lower end of the conductor tube (for example, in combination with a drip proofed sealing end). The drip proofed sealing end is often required in the service requirements. In this case, it is not possible to use type A because of the existing double fixation. Therefore, both bushing types A and B have to be specified. The condition for the usage of type B is that the drip prooved sealing end is able to withstand the mechanical stress in axial direction.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to ceramic and resin insulated bushings having highest voltages above 1 kV up to 52 kV, rated currents from 250 A up to 3 150 A and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers. This standard establishes essential dimensions, to ensure interchangeability of bushings and to ensure adequate mounting and interchangeability of mating plug-in separable connectors of equivalent ratings.
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60137:2008 gives the characteristics and tests for insulated bushings intended for use in electrical apparatus, machinery, transformers, switchgear and installations for three-phase alternating current systems, having highest voltage for equipment above 1 000 V and power frequencies of 15 Hz up to and including 60 Hz. Special requirements and tests for transformer bushings in this standard apply also to reactor bushings. This edition includes the following significant technical changes with respect to the previous edition: - Long duration power-frequency for transformer bushings; - Special requirements for type and acceptance tests applicable to transformer and GIS bushings; - Specific insulation levels for bushings fitted to transformers and GIS; - According to IEC Guide 111, clauses relating to safety and the environment have been added; and - The altitude correctino procedure has been revised (> 1 000 m).
- Standard61 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to outdoor and indoor bushings of any voltage used on d.c. systems, of capacitance graded or gas insulated types for use as components of oil-filled converter transformers and smoothing reactors, as well as air-to-air d.c. bushings.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies the characteristics and tests for insulated bushings intended for use in electrical apparatus, machinery, transformers, switchgear and installations for three-phase alternating current systems, having highest voltage for equipment above 1 000 V and power frequencies of 15 Hz up to and including 60 Hz. Special requirements and tests for transformer bushings in this standard apply also to reactor bushings.
- Standard54 pagesEnglish languagesale 10% offe-Library read for1 day
Supersedes HD 596 S1:1996 * D129/C012: TC 36A invited to consider TC 14 request to start the revision of EN 50386:2002 * Superseded by EN 50386:2010
- Standard6 pagesEnglish languagesale 10% offe-Library read for1 day
This standard is applicable to insulated bushings for use in air insulated, shroud insulated and fully insulated cable boxes for liquid filled transformers and reactors for rated voltages up to 36 kV, and rated currents up to 4 000 A at frequencies from 15 Hz to 60 Hz.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This standard is applicable to ceramic and resin insulated bushings for rated voltages above 1 kV up to 36 kV rated currents from 250A up to 3150 A and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers. This standard establishes essential dimensions, to ensure interchangeability of bushings and to ensure adequate mounting and interchangeability of mating plug-in separable connectors of equivalent ratings
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This standard is applicable to insulated bushings for rated voltages above 1 kV up to 36kV, rated currents from 250 A up to 1.250 A and frequencies from 15 Hz up to 60 Hz for equipment other than liquid filled transformers. This standard establishes essential dimensions, to ensure adequate mounting and interchangeability of mating plug-in separable connectors of equivalent ratings
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies the characteristics and tests for insulated bushings. Is applicable to bushings, as defined in clause 2, intended for use in electrical apparatus, machinery, transformers, switchgear and installations for three-phase alternating current systems, having rated voltages above 100 V and power-frequencies of 15 Hz up to and including 60 Hz. Special requirements and tests for transformer bushings in this standard apply also to reactor bushings. This standard may also be used analogously for bushings for use in other than three-phase systems, e.g. for rectifiers, testing transformers, or for terminals for power cables (potheads) and capacitors.
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50387:2002
- Standardization document5 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50386:2002
- Standardization document6 pagesEnglish languagesale 10% offe-Library read for1 day