IEC/TC 28 - IEC_TC_28
For power systems with nominal voltages above 1000 V a.c. and 1500 V d.c., to prepare international standards regarding: 1. A set of definitions used for insulation standardization and co-ordination. 2. The basic principles of insulation co-ordination. 3. The field of application. 4. The specification of a series of standard insulation levels (without regard to any particular type of equipment). 5. A full statement of the tests to be included in the specification of the equipment to meet the insulation levels to be used in relation to the possibilities of overvoltage protective devices. 6. Recommendations for the minimum clearance distance in air between live parts. 7. An application guide for the users of electrical equipment recommending the insulation levels to be used in relation to the possibilities of over-voltage protective devices
IEC_TC_28
For power systems with nominal voltages above 1000 V a.c. and 1500 V d.c., to prepare international standards regarding: 1. A set of definitions used for insulation standardization and co-ordination. 2. The basic principles of insulation co-ordination. 3. The field of application. 4. The specification of a series of standard insulation levels (without regard to any particular type of equipment). 5. A full statement of the tests to be included in the specification of the equipment to meet the insulation levels to be used in relation to the possibilities of overvoltage protective devices. 6. Recommendations for the minimum clearance distance in air between live parts. 7. An application guide for the users of electrical equipment recommending the insulation levels to be used in relation to the possibilities of over-voltage protective devices
General Information
2021-08-25 (data): Work of CLC/SR 28 transferred to CLC/TC 99X (D167/C115)
- Addendum – translation9 pagesSlovenian languagesale 10% offe-Library read for1 day
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment9 pagesFrench languagesale 10% offe-Library read for1 day
IEC 60071-1:2006 applies to three-phase a.c. systems having a highest voltage for equipment above 1 kV. It specifies the procedure for the selection of the rated withstand voltages for the phase-to-earth, phase-to-phase and longitudinal insulation of the equipment and the installations of these systems. It also gives the lists of the standard withstand voltages from which the rated withstand voltages should be selected. This standard recommends that the selected withstand voltages should be associated with the highest voltage for equipment. This association is for insulation co-ordination purposes only. The requirements for human safety are not covered by this standard. Although the principles of this standard also apply to transmission line insulation, the values of their withstand voltages may be different from the standard rated withstand voltages. The apparatus committees are responsible for specifying the rated withstand voltages and the test procedures suitable for the relevant equipment taking into consideration the recommendations of this standard. NOTE: In IEC 60071-2, Application Guide, all rules for insulation co ordination given in this standard are justified in detail, in particular the association of the standard rated withstand voltages with the highest voltage for equipment. When more than one set of standard rated withstand voltages is associated with the same highest voltage for equipment, guidance is provided for the selection of the most suitable set. The main changes from the previous edition are as follows: - in the definitions (3.26, 3.28 and 3.29) and in the environmental conditions (5.9) taken into account clarification of the atmospheric and altitude corrections involved in the insulation co-ordination process; - in the list of standard rated short-duration power frequency withstand voltages reported in 5.6 addition of 115 kV; - in the list of standard rated impulse withstand voltages reported in 5.7, addition of 200 kV and 380 kV; - in the standard insulation levels for range I (1kV < Um 245 kV) (Table 2) addition of the highest voltage for equipment Um = 100 kV; - in the standard insulation levels for range II (Um 245 kV) (Table 3) replacement of 525 kV by 550 kV and of 765 kV by 800 kV; - in order to remove that part in the next revision of IEC 60071-2, addition of Annex A dealing with clearances in air to assure a specified impulse withstand voltage in installation; - in Annex B, limitation at two Um values for the values of rated insulation levels for 1kV < Um 245 kV for highest voltages for equipment Um not standardized by IEC based on current practice in some countries. It has the status of a horizontal standard in accordance with IEC Guide 108.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard38 pagesFrench languagesale 10% offe-Library read for1 day
- Standard – translation38 pagesSlovenian languagesale 10% offe-Library read for1 day
Gives guidance for the determination of the rated withstand voltages for ranges I and II of EN 60071-1 and justifies the association of these rated values with the standardized highest voltages for equipment. It covers phase-to-phase, phase-to-earth and longitudinal insulation of three-phase systems with nominal voltages above 1kV
- Standard129 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to three phase alternating current systems having a highest voltage for equipment above 1 kV. Specifies the procedures for the selection of the standard withstand voltages for the phase to earth, phase to phase and longitudinal insulation of the equipment and the installations of these systems.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day