ISO/TR 80002-2:2017(E) applies to any software used in device design, testing, component acceptance, manufacturing, labelling, packaging, distribution and complaint handling or to automate any other aspect of a medical device quality system as described in ISO 13485.
ISO/TR 80002-2:2017 applies to
- software used in the quality management system,
- software used in production and service provision, and
- software used for the monitoring and measurement of requirements.
It does not apply to
- software used as a component, part or accessory of a medical device, or
- software that is itself a medical device.

  • Technical report
    84 pages
    English language
    sale 15% off

Defines the life cycle requirements for medical device software. The set of processes, activities, and tasks described in this standard establishes a common framework for medical device software life cycle processes. Applies to the development and maintenance of medical device software when software is itself a medical device or when software is an embedded or integral part of the final medical device. This standard does not cover validation and final release of the medical device, even when the medical device consists entirely of software.

  • Standard
    155 pages
    English and French language
    sale 15% off

IEC TR 80002-3:2014 which is a technical report (TR), provides the description of software life cycle processes for medical devices. The medical device software life cycle processes are derived from IEC 62304:2006, with corresponding safety classes. They have been aligned with the software development life cycle processes of ISO/IEC 12207:2008 and are presented herein in full compliance with ISO/IEC 24774:2010. The content of these three standards provides the foundation of this TR. This TR does not:
- address areas already covered by existing related standards, e.g. the international standards that relate to the four standards used to build this TR (see Bibliography);
- FDA guidance documents; or
- software development tools. This TR describes the process reference model for medical device software development and is limited in scope to the life cycle processes described in IEC 62304:2006. The process names correspond to those of IEC 62304:2006. The mappings provided in Annex B are essential for the alignment between IEC 62304:2006 (which is based on ISO/IEC 12207:1995) and ISO/IEC 12207:2008, developed to address the detailed normative relationship between the two standards. This technical report is not intended to be used as the basis of regulatory inspection or certification assessment activities.

  • Technical report
    28 pages
    English language
    sale 15% off

IEC/TR 80002-1:2009(E) provides guidance for the application of the requirements contained in ISO 14971:2007, Medical devices - Application of risk management to medical devices to medical device software with reference to IEC 62304:2006, Medical device software - Software life cycle processes. It does not add to, or otherwise change, the requirements of ISO 14971:2007 or IEC 62304:2006. IEC/TR 80002-1:2009(E) is aimed at risk management practitioners who need to perform risk management when software is included in the medical device/system, and at software engineers who need to understand how to fulfil the requirements for risk management addressed in ISO 14971. ISO 14971, recognized worldwide by regulators, is widely acknowledged as the principal standard to use when performing medical device risk management. IEC 62304:2006, makes a normative reference to ISO 14971 requiring its use. The content of these two standards provides the foundation for this technical report. It should be noted that even though ISO 14971 and this technical report focus on medical devices, this technical report may be used to implement a safety risk management process for all software in the healthcare environment independent of whether it is classified as a medical device. IEC/TR 80002-1:2009 is not intended to be used as the basis of regulatory inspection or certification assessment activities.

  • Technical report
    64 pages
    English language
    sale 15% off