MT 60077 - TC 9/MT 60077
TC 9/MT 60077
General Information
IEC 60077-5:2019 is available as IEC 60077-5:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60077-5:2019 give additional or amended rules for high voltage (HV) fuses as a supplement to those given by IEC 60077-2. The high voltage fuses concerned are those connected into power and/or auxiliary circuits. The nominal voltage of these circuits lies between 600 V DC and 3 000 V DC, according to IEC 60850. These fuses can also be used in auxiliary AC circuits up to a nominal voltage of 1 500 V. This document together with IEC 60077-2 states specifically:
a) the characteristics of the fuses;
b) the service conditions with which the fuses comply with reference to:
- operation and behaviour in normal service;
- operation and behaviour in case of short circuit;
- dielectric properties.
c) the tests intended for confirming the compliance of the fuse with the characteristics under the service conditions and the methods adopted for these tests;
d) the information marked on, or given with, the fuse.
This second edition cancels and replaces the first edition, issued in 2003. This edition includes the following main technical changes with regard to the previous edition:
a) test method of test duty III for verification of breaking capacity is reviewed.
- Standard58 pagesEnglish and French languagesale 15% off
IEC 60077-4:2019 is available as IEC 60077-4:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60077-4:2019 gives rules for AC circuit-breakers, the main contacts of which are connected to AC overhead contact lines; the nominal voltage of these circuits being in accordance with IEC 60850. This document, together with IEC 60077-2, states specifically:
a) the characteristics of the circuit-breakers;
b) the service conditions with which circuit-breakers comply with reference to:
- operation and behaviour in normal service;
- operation and behaviour in short-circuit;
- dielectric properties;
c) the tests for confirming the compliance of the components with the characteristics under the service conditions and the methods to be adopted for these tests
d). the information to be marked on, or given with the circuit-breaker.
This second edition cancels and replaces the first edition, issued in 2003. This edition includes the following main technical changes with regard to the previous edition:
a) standard values of transient recovery voltages and test procedure are reviewed;
b) procedure of verification of temperature rise is changed;
c) air-tightness test as type test, insulation resistance measurement are added
- Standard60 pagesEnglish and French languagesale 15% off
IEC 60077-3:2019 is available as IEC 60077-3:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60077-3:2019 gives the rules for circuit-breakers, the main contacts of which are connected to DC power and/or auxiliary circuits. The nominal voltage of these circuits does not exceed 3 000 V DC according to IEC 60850. This part of IEC 60077, together with IEC 60077-2, states specifically:
a) the characteristics of the circuit-breakers;
b) the service conditions with which circuit-breakers complies with reference to:
- operation and behaviour in normal service;
- operation and behaviour in the case of short circuit
- dielectric properties;
c) the tests for confirming the compliance of the components with the characteristics under the service conditions and the methods to be adopted for these tests;
d) the information to be marked on, or given with, the circuit breaker.
This second edition cancels and replaces the first edition, issued in 2001. This edition includes the following main technical changes with regard to the previous edition:
- procedure of verification of temperature rise is changed;
- air-tightness test as type test, insulation resistance measurement are added.
- Standard58 pagesEnglish and French languagesale 15% off
IEC 60077-1:2017 is now available as IEC 60077-1:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60077-1:2017 specifies the general service conditions and requirements for all electric equipment installed in power circuits, auxiliary circuits, control and indicating circuits etc., on railway rolling stock. The purpose of this document is to harmonize as far as practicable all rules and requirements of a general nature applicable to electric equipment for rolling stock. This new edition includes the following main technical changes with regard to the previous edition:
- descriptions regarding insulation coordination, environmental conditions and those of current return and protective bonding are deleted and replaced by references to IEC 62497‑1, IEC 62498-1 and IEC 61991;
- classification of equipment type is introduced;
- temperature limits and temperature rise tests are reviewed.
- Standard105 pagesEnglish and French languagesale 15% off
IEC 60077-2:2017 is now available as IEC 60077-2:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60077-2:2017 provides general rules for all electrotechnical components installed in power circuits, auxiliary circuits, control and indicating circuits, etc., on railway rolling stock. The purpose of this document is to adapt the general rules given in IEC 60077-1 to all electrotechnical components for rolling stock, in order to obtain uniformity of requirements and tests for the corresponding range of components. This new edition includes the following main technical changes with regard to the previous edition:
- short circuit breaking capacity;
- rated short-time withstand current;
- critical currents range;
- specification of climatic conditions.
This standard is to be read in conjunction with IEC 60077-1:2017.
- Standard71 pagesEnglish and French languagesale 15% off