IEC 80601-2-77:2019 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ROBOTICALLY ASSISTED SURGICAL EQUIPMENT (RASE) and ROBOTICALLY ASSISTED SURGICAL SYSTEMS (RASS), referred to as ME EQUIPMENT and ME SYSTEMS together with their INTERACTION CONDITIONS and INTERFACE CONDITIONS.

    • sale 15% off
    • Standard
      111 pages
      English and French language

This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HF
SURGICAL EQUIPMENT and HF SURGICAL ACCESSORIES as defined in 201.3.224 and 201.3.223.
HF SURGICAL EQUIPMENT having a RATED OUTPUT POWER not exceeding 50 W (for example for
micro-COAGULATION, or for use in dentistry or ophthalmology) is exempt from certain of the
requirements of this particular standard. These exemptions are indicated in the relevant
requirements.

    • sale 10% off
    • Standard
      93 pages
      English language
    • e-Library read for
      1 day

NEW!IEC 60601-2-2:2017 is available as IEC 60601-2-2:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60601-2-2:2017 applies to the basic safety and essential performance of HF surgical equipment and HF surgical accessories. HF surgical equipment having a rated output power not exceeding 50 W (for example for micro-coagulation, or for use in dentistry or ophthalmology) is exempt from cert...view more

    • sale 10% off
    • Standard
      93 pages
      English language
    • e-Library read for
      1 day

ISO 10936-1:2017 specifies requirements and refers to test methods for operation microscopes used for observation during surgical operation and treatment of patients. It does not apply to accessories, e.g. photographic cameras. NOTE Specific requirements with regard to optical radiation hazards from operation microscopes used in ocular surgery are given in ISO 10936‑2.

    • sale 15% off
    • Standard
      4 pages
      English language

IEC 60601-2-2:2017 is also available as IEC 60601-2-2:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60601-2-2:2017 applies to the basic safety and essential performance of HF surgical equipment and HF surgical accessories.
HF surgical equipment having a rated output power not exceeding 50 W (for example for micro-coagulation, or for use in dentistry or ophthalmology) is exempt fro...
view more

    • sale 15% off
    • Standard
      186 pages
      English and French language

This part of ISO 7153 specifies metals commonly used to manufacture various types of standard
surgical instruments, including but not limited to those used in general surgery, orthopaedics and
dentistry.
While this part of ISO 7153 is not intended for surgical instruments used in special applications, such
as implantology and minimally invasive surgery, parts of it might be applicable to those instruments.
NOTE When selecting the grade of steel and the shape, dimensions and delivery conditi...
view more

    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day

ISO 7153-1:2016 specifies metals commonly used to manufacture various types of standard surgical instruments, including but not limited to those used in general surgery, orthopaedics and dentistry.
While ISO 7153-1:2016 is not intended for surgical instruments used in special applications, such as implantology and minimally invasive surgery, parts of it might be applicable to those instruments.

    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day

ISO 7153-1:2016 specifies metals commonly used to manufacture various types of standard surgical instruments, including but not limited to those used in general surgery, orthopaedics and dentistry. While ISO 7153-1:2016 is not intended for surgical instruments used in special applications, such as implantology and minimally invasive surgery, parts of it might be applicable to those instruments.

    • sale 15% off
    • Standard
      13 pages
      English language
    • sale 15% off
    • Standard
      10 pages
      French language
    • sale 15% off
    • Standard
      10 pages
      French language
    • sale 15% off
    • Standard
      13 pages
      English language

This International Standard is applicable to disposable and reusable, as well as woven and non-woven
materials used as surgical drapes and other patient-protective covers which claim to be laser-resistant.
The purpose of this International Standard is to provide a standardized method for testing and
classifying surgical drapes and other patient-protective covers with respect to laser-induced hazards.
An appropriate classification system is given. It is not the purpose of this International S...
view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

ISO 11810:2015 is applicable to disposable and reusable, as well as woven and non-woven materials used as surgical drapes and other patient-protective covers which claim to be laser-resistant. The purpose of this International Standard is to provide a standardized method for testing and classifying surgical drapes and other patient-protective covers with respect to laser-induced hazards. An appropriate classification system is given. It is not the purpose of this International Standard to serve ...view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

ISO 11810:2015 is applicable to disposable and reusable, as well as woven and non-woven materials used as surgical drapes and other patient-protective covers which claim to be laser-resistant. The purpose of this International Standard is to provide a standardized method for testing and classifying surgical drapes and other patient-protective covers with respect to laser-induced hazards. An appropriate classification system is given. It is not the purpose of this International Standard to serve ...view more

    • sale 15% off
    • Standard
      21 pages
      English language
    • sale 15% off
    • Standard
      23 pages
      French language

2020-11-04-JO - lack of compliance. Refereince is made  CLC/TC 62 Decision 02/2019 in Oslo 2019 to decouple work items from MDD and AIMD for projects that do not yet have an Annex ZZ approved by the HAS consultant.. Following exchange with TC leadership and given that the transition of MDD ends in May 2021, the TC will rather focus on the citation of their standards under the MDR. The link to MDD and M/295  removed to the published standard

    • sale 10% off
    • Amendment
      7 pages
      English language
    • e-Library read for
      1 day

This International Standard specifies general requirements for instruments to be used in association with
non-active surgical implants. These requirements apply to instruments when they are manufactured
and when they are resupplied after refurbishment.
This International Standard also applies to instruments which may be connected to power-driven
systems, but does not apply to the power-driven systems themselves.
With regard to safety, this International Standard gives requirements for inten...
view more

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day

ISO 16061:2015 specifies general requirements for instruments to be used in association with non-active surgical implants. These requirements apply to instruments when they are manufactured and when they are resupplied after refurbishment.
This International Standard also applies to instruments which may be connected to power-driven systems, but does not apply to the power-driven systems themselves.
With regard to safety, this International Standard gives requirements for intended performance,...
view more

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day

ISO 13504:2012 specifies general requirements for the manufacture of instruments and related accessories used in the placement of dental implants and further manipulations of connecting parts in the craniofacial area.
It is applicable to single-use and reusable instruments, regardless of whether they are manually driven or connected to a power-driven system.

    • sale 10% off
    • Standard
      23 pages
      English language
    • e-Library read for
      1 day

This particular standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of SURGICAL LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS, hereafter referred to as ME EQUIPMENT. This particular standard does not apply to - headlights; - endoscopes, laparoscopes and their light sources, which are covered by IEC 60601-2-18; - luminaires used in dentistry, which are covered by ISO 9680; - luminaires for general purposes, which are covered by IEC 60598-2-1 and IEC 60598-2-4; - luminaires dedicated to thera...view more

    • sale 10% off
    • Amendment
      3 pages
      English language
    • e-Library read for
      1 day

This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HF SURGICAL EQUIPMENT as defined in 201.3.222. HF SURGICAL EQUIPMENT having a RATED OUTPUT POWER not exceeding 50 W (for example for micro-COAGULATION, or for use in dentistry or ophthalmology) is exempt from certain of the requirements of this particular standard. These exemptions are indicated in the relevant requirements.

    • sale 10% off
    • Amendment
      3 pages
      English language
    • e-Library read for
      1 day

This particular standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of SURGICAL LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS, hereafter referred to as ME EQUIPMENT. This particular standard does not apply to - headlights; - endoscopes, laparoscopes and their light sources, which are covered by IEC 60601-2-18; - luminaires used in dentistry, which are covered by ISO 9680; - luminaires for general purposes, which are covered by IEC 60598-2-1 and IEC 60598-2-4; - luminaires dedicated to thera...view more

    • sale 10% off
    • Standard
      44 pages
      English language
    • e-Library read for
      1 day

ISO 10936-2:2010 specifies requirements and test methods for optical radiation hazards from operation microscopes that are used during ophthalmic surgery.

    • sale 15% off
    • Standard
      4 pages
      English language
    • sale 15% off
    • Standard
      4 pages
      French language
    • sale 15% off
    • Standard
      4 pages
      English language