ASTM F1245-89(2001)
(Specification)Standard Specification for Faucets, Single and Double, Compression and Self-Closing Type, Shipboard
Standard Specification for Faucets, Single and Double, Compression and Self-Closing Type, Shipboard
SCOPE
1.1 This specification covers single and double compression and self-closing faucets for shipboard plumbing installations.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 The following precautionary caveat pertains only to the test methods portion, Section 10, of this standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: F 1245 – 89 (Reapproved 2001)
Standard Specification for Faucets, Single and Double,
1
Compression and Self-Closing Type, Shipboard
This standard is issued under the fixed designation F 1245; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope MIL-P-116 Preservation, Methods of
4
2.5 Military Standards:
1.1 This specification covers single- and double-
MIL-STD-105 Sampling Procedures and Tables for Inspec-
compression and self-closing faucets for shipboard plumbing
tion by Attributes
installations.
MIL-STD-129 Marking for Shipment and Storage
1.2 Thevaluesstatedininch-poundunitsaretoberegarded
4
2.6 Naval Sea Systems Command (NAVSEA):
as the standard. The values given in parentheses are for
NAVSEA Drawing 803-5959206 Faucet, Metering
information only.
NAVSEA Drawing 805-1623970 Unit, Lavatory for Offic-
1.3 The following precautionary caveat pertains only to the
ers Station
test methods portion, Section 10, of this standard. This stan-
dard does not purport to address all of the safety concerns, if
3. Classification
any, associated with its use. It is the responsibility of the user
3.1 Faucets shall be of the following types and classes as
of this standard to establish appropriate safety and health
specified (see 4.1):
practices and determine the applicability of regulatory limita-
3.1.1 Type I—Standard (bibb):
tions prior to use.
3.1.1.1 Class A—Compression, plain end.
2. Referenced Documents 3.1.1.2 Class B—Compression, hose end.
3.1.1.3 Class C—Self-closing.
2.1 ASTM Standards:
3.1.2 Type II—Lavatory, self-closing, low spout.
B62 Specification for Composition Bronze or Ounce Metal
2
3.1.2.1 Class A—Fast-closing.
Castings
3.1.2.2 Class B—Slow-closing, depression type.
B584 Specification for Copper Alloy Sand Castings for
2
3.1.3 Type III—Folding lavatory, self-closing.
General Applications
3 3.1.4 Type IV—Elbow operated.
2.2 American National Standards Institute Standard:
3.1.5 Type V—Lavatory, combination water supply and
B1.1 Unified Inch Screw Threads (UN and UNR Thread
drain fixture.
Form)
4
3.1.6 Type VI—Combination supply fixture swing spout for
2.3 Federal Specifications:
use on galley sinks.
PPP-B-566 Boxes, Folding, Paperboard
3.1.7 Type VII—Single supply fixture swing spout for use
PPP-B-585 Boxes, Wood, Wirebound
with steam kettles and urns.
PPP-B-591 Boxes, Shipping, Fiberboard, Wood-Cleated
3.1.7.1 Class A—Spout for overhead supply.
PPP-B-601 Boxes, Wood, Cleated-Plywood
3.1.7.2 Class B—Spout for riser supply.
PPP-B-621 Boxes, Wood, Nailed and Lock-Corner
3.1.8 Type VIII—Supplyfixtureforpressedmetalandshock
PPP-B-636 Box, Shipping, Fiberboard
mounted china lavatories.
PPP-B-676 Boxes, Setup
3.1.9 Type IX—Lavatory, combination water supply and
QQ-N-290 Nickel Plating (Electrodeposited)
drain fixtures, depression type.
QQ-C-320 Chromium Plating (Electrodeposited)
4
2.4 Military Specification:
4. Ordering Information
4.1 Orders for equipment under this specification shall
1
This specification is under the jurisdiction ofASTM Committee F25 on Ships include the following information, as required, to describe the
and Marine Technology and is the direct responsibility of Subcommittee F25.11 on
equipment adequately:
Machinery and Piping Systems.
4.1.1 ASTM designation and year of issue,
Current edition approved Sept. 29, 1989. Published November 1989.
2
4.1.2 Type and class of faucet required (see 3.1),
Annual Book of ASTM Standards, Vol 02.01.
3
Available from American National Standards Institute, 25 W. 43rd St., 4th 4.1.3 Type of handle required (see 6.11),
Floor, New York, NY 10036.
4.1.4 Marking required for handles (see 13.1),
4
AvailablefromStandardizationDocumentsOrderDesk,Bldg.4SectionD,700
4.1.5 Size and weight of Type I faucet required (see 7.1),
Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
F 1245 – 89 (2001)
4.1.6 Overall dimensions for Type II faucets (see 7.2),
4.1.7 ShankdesignforTypeII,ClassBfaucets(see6.2.3.2),
4.1.8 Overall dimensions and position of inlet (side or
bottom) for Type III faucets (see 7.3),
4.1.9 Overall dimensions and whether spray is required for
Type IV faucets (see 6.4.1.3 and 7.4),
4.1.10 Length of spout for Type VI fixtures (see 7.6.1),
4.1.11 Whether escutcheon plates are provided for Type VI
faucets (see 6.6.3),
1
4.1.12 Whether connections are other than ⁄4-in. nominal
pipe size (NPS) (see 6.8.2.1),
4.1.13 Sample size for examination and t
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.