ASTM E726-01
(Test Method)Standard Test Method for Particle Size Distribution of Granular Carriers and Granular Pesticides
Standard Test Method for Particle Size Distribution of Granular Carriers and Granular Pesticides
SCOPE
1.1 This test method is used to determine the particle size distribution of granular carriers and granular pesticides.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 6.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:E726–01
Standard Test Method for
Particle Size Distribution of Granular Carriers and Granular
1
Pesticides
This standard is issued under the fixed designation E 726; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 5. Apparatus
1.1 This test method is used to determine the particle size 5.1 Brushes; Tyler Part No. 8576 soft brass wire brush, or
distribution of granular carriers and granular pesticides. equivalent, for 100 mesh (150 µm) and coarser sieves. Tyler
1.2 This standard does not purport to address all of the nylon bristle brush (Part No. 8577), or equivalent, for screens
3
safety concerns, if any, associated with its use. It is the finer than 100 mesh.
4
responsibility of the user of this standard to establish appro- 5.2 Mechanical Sieve Shaker; a Tyler RoTap sieve shaker,
priate safety and health practices and determine the applica- or equivalent, or other agreed upon device.
bility of regulatory limitations prior to use. For specific hazard 5.3 Sieves; U.S. standard 8-in. (20.3 cm) diameter sieves,
statements, see Section 6. or equivalent, conforming to SpecificationE11.
5.4 Bottom Receiver Pan and Top Sieve Cover.
2. Referenced Documents
5.5 Interval Timer; adjustable, with an accuracy of 610 s.
2
2.1 ASTM Standards: 5.6 Balance; sensitivity of 0.1 g.
E11 Specification for Wire-Cloth Sieves for Testing Pur-
6. Hazards
poses
E 725 Test Method of Sampling Granular Carriers and 6.1 Before testing, read the precautionary statements on the
Granular Pesticides productlabel,andtheMaterialSafetyDataSheet,orboth.Take
proper precautions to prevent skin contact and inhalation of the
3. Summary of Test Method
fines, or the vapors, or both. Take care to prevent contamina-
3.1 A known weight of the granular carrier or granular tion of the surrounding area. Always wear the appropriate
pesticide is placed on the top sieve of a stacked set of U.S. safety equipment and, where indicated, wear respiratory de-
standard sieves and shaken under standard conditions for a
vices approved by NIOSH for the product being tested.
specified period of time. The weight percent of the granules
7. Procedure
retained on each sieve and the bottom pan is determined.
7.1 Clean and stack the specified sieves in order of size with
4. Significance and Use
the pan on the bottom, and the sieve with the largest mesh on
4.1 This procedure was designed principally for clay, corn-
the top.
cob, nut shell paper, or sand granular carriers and granular 7.2 Use a representative sample of approximately 10065g
pesticide products, but need not be limited to these materials.
as defined in Test Method E 725.
There may be more appropriate test methods for other types of 7.3 Weigh the sample to 60.1 g.
granular carriers and products.
7.4 Transfer the whole weighed fraction onto the top sieve,
cover and shake for the time given in the product specification
or 10 min if time is not specified.
7.5 Remove the sieve assembly from the sieve shaker and,
1
This test method is under the jurisdiction of ASTM Committee E-35 on
using the brush, quantitatively transfer the granular material on
Pesticides and is
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.