Standard Test Method for Time of Setting of Hydraulic Cement Mortar by Modified Vicat Needle

SIGNIFICANCE AND USE
The purpose of this test method is to establish whether or not a cement complies with a specification limit on time of setting. It has been found to be particularly applicable for the determination of the setting time of expansive cements (see Specification C 845).
SCOPE
1.1 This test method covers the determination of the time of setting of hydraulic cement mortar by means of the modified Vicat needle.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. The use of gloves, protective clothing, and eye protection is recommended. Wash contact area with copious amounts of water after contact. Wash eyes for a minimum of 15 min. Avoid exposure of the body to clothing saturated with the liquid phase of the unhardened material. Remove contaminated clothing immediately after exposure.)
1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

General Information

Status
Historical
Publication Date
31-May-2008
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C807-08 - Standard Test Method for Time of Setting of Hydraulic Cement Mortar by Modified Vicat Needle
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM C807-08 - Standard Test Method for Time of Setting of Hydraulic Cement Mortar by Modified Vicat Needle
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C807 −08
StandardTest Method for
Time of Setting of Hydraulic Cement Mortar by Modified
1
Vicat Needle
This standard is issued under the fixed designation C807; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* C187 Test Method for Amount of Water Required for Nor-
mal Consistency of Hydraulic Cement Paste
1.1 This test method covers the determination of the time of
C219 Terminology Relating to Hydraulic Cement
setting of hydraulic cement mortar by means of the modified
C305 Practice for Mechanical Mixing of Hydraulic Cement
Vicat needle.
Pastes and Mortars of Plastic Consistency
1.2 The values stated in SI units are to be regarded as
C511 Specification for Mixing Rooms, Moist Cabinets,
standard. No other units of measurement are included in this
Moist Rooms, and Water Storage Tanks Used in the
standard.
Testing of Hydraulic Cements and Concretes
1.3 This standard does not purport to address all of the
C670 Practice for Preparing Precision and Bias Statements
safety concerns, if any, associated with its use. It is the for Test Methods for Construction Materials
responsibility of the user of this standard to establish appro-
C778 Specification for Sand
priate safety and health practices and determine the applica- C845 Specification for Expansive Hydraulic Cement
bility of regulatory limitations prior to use. (Warning—Fresh
C1005 Specification for Reference Masses and Devices for
hydraulic cementitious mixtures are caustic and may cause Determining Mass and Volume for Use in the Physical
chemical burns to skin and tissue upon prolonged exposure.
Testing of Hydraulic Cements
The use of gloves, protective clothing, and eye protection is D1193 Specification for Reagent Water
recommended. Wash contact area with copious amounts of
3. Terminology
wateraftercontact.Washeyesforaminimumof15min.Avoid
exposureofthebodytoclothingsaturatedwiththeliquidphase
3.1 Terms used in this standard are defined in Terminology
of the unhardened material. Remove contaminated clothing
C219.
immediately after exposure.)
1.4 The text of this standard references notes and footnotes
4. Summary of Test Method
which provide explanatory material. These notes and footnotes
4.1 Amortar is prepared with the cement to be tested, using
(excluding those in tables and figures) shall not be considered
stipulated quantities of cement and water, and sufficient stan-
as requirements of the standard.
dard sand to produce a required consistency as determined by
a stipulated penetration using the plunger of the modifiedVicat
2. Referenced Documents
apparatus. Mortar of the proper consistency is then tested for
2
2.1 ASTM Standards:
time of setting, using the needle of the modified Vicat
C109/C109M Test Method for Compressive Strength of
apparatus for the determination of a stipulated penetration.The
Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube
time required to obtain the stipulated penetration of the
Specimens)
modified Vicat needle is the time of setting.
C183 Practice for Sampling and the Amount of Testing of
Hydraulic Cement 5. Significance and Use
5.1 The purpose of this test method is to establish whether
or not a cement complies with a specification limit on time of
1
This test method is under the jurisdiction ofASTM Committee C01 on Cement
setting. It has been found to be particularly applicable for the
and is the direct responsibility of Subcommittee C01.30 on Time of Set.
determination of the setting time of expansive cements (see
CurrenteditionapprovedJune1,2008.PublishedJuly2008.Originallyapproved
Specification C845).
in 1975. Last previous edition approved in 2005 as C807 – 05. DOI: 10.1520/
C0807-08.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or 6. Apparatus
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
6.1 Tamper and Trowel, conforming to the requirements of
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. Test Method C109/C109M. In addition, the edges of the trowel
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C807−08
when placed on a plane surface shall not depart from straight- 10.1.2 Upon completion of mixing, place a layer of mortar
ness by more than 1 mm. about 20 mm in thickness in the mold and puddle with the
tamper. Hold the tamper with the 25-mm side parallel to the
6.2 VicatApparatus, conforming to the requirement
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C807–05 Designation: C 807 – 08
Standard Test Method for
Time of Setting of Hydraulic Cement Mortar by Modified
1
Vicat Needle
This standard is issued under the fixed designation C 807; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This test method covers the determination of the time of setting of hydraulic cement mortar by means of the modified Vicat
needle.
1.2The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and
tissue upon prolonged exposure. The use of gloves, protective clothing, and eye protection is recommended. Wash contact area
withcopiousamountsofwateraftercontact.Washeyesforaminimumof15min.Avoidexposureofthebodytoclothingsaturated
with the liquid phase of the unhardened material. Remove contaminated clothing immediately after exposure.)
1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as requirements of the standard.
2. Referenced Documents
2
2.1 ASTM Standards:
C 109/C 109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
C 183 Practice for Sampling and the Amount of Testing of Hydraulic Cement
C 187 Test Method for Normal Consistency of Hydraulic Cement
C 219 Terminology Relating to Hydraulic Cement
C 305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency
C 511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of
Hydraulic Cements and Concretes
C 670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
C 778 Specification for Standard Sand
C 845 Specification for Expansive Hydraulic Cement
C 1005 Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing of
Hydraulic Cements
D 1193 Specification for Reagent Water
3. Terminology
3.1 Terms used in this standard are defined in Terminology C 219.
4. Summary of Test Method
4.1 A mortar is prepared with the cement to be tested, using stipulated quantities of cement and water, and sufficient standard
sand to produce a required consistency as determined by a stipulated penetration using the plunger of the modifiedVicat apparatus.
Mortar of the proper consistency is then tested for time of setting, using the needle of the modified Vicat apparatus for the
determination of a stipulated penetration. The time required to obtain the stipulated penetration of the modified Vicat needle is the
time of setting.
1
This test method is under the jurisdiction of ASTM Committee C01 on Cement and is the direct responsibility of Subcommittee C01.30 on Time of Set.
Current edition approved MayJune 1, 2005.2008. Published May 2005.July 2008. Originally approved in 1975. Last previous edition approved in 20032005 as
C807–03a.C 807 – 05.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. ForAnnualBookofASTMStandards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C807–08
5. Significance and Use
5.1 The purpose of this test method is to establish whether or not a cement complies with a specification limit on time of setting.
It has been found to be particularly applicable for the determination of the setting time of expansive cements (see Specification
C 845).
6. Apparatus
6.1 Tampe
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.