ASTM F1018-87a(1999)e1
(Specification)Standard Specification for Steel Emergency Gear Stowage Locker
Standard Specification for Steel Emergency Gear Stowage Locker
SCOPE
1.1 This specification covers the design, material, and manufacture of steel emergency gear stowage lockers.
1.2 Emergency gear lockers shall be of four types (see Section 3).
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
e1
Designation: F 1018 – 87a (Reapproved 1999)
Standard Specification for
Steel Emergency Gear Stowage Locker
This standard is issued under the fixed designation F 1018; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
e NOTE—Keywords added editorially in October 2000.
1. Scope 2.3 Other Documents:
ABS Rules for Building and Classing Steel Vessels
1.1 This specification covers the design, material, and
SSPC Specification 6
manufacture of steel emergency gear stowage lockers.
AWS D1.1 Welding Code
1.2 Emergency gear lockers shall be of four types (see
Section 3).
3. Classification
1.3 The values stated in inch-pound units are to be regarded
3.1 Emergency gear lockers shall be classified in four types
as the standard. The values given in parentheses are for
as follows:
information only.
3.1.1 Type 1—For stowage of one complete fireman’s outfit,
2. Referenced Documents conforming to all requirements of all sections, figures, and
details of this specification.
2.1 ASTM Standards:
3.1.2 Type 2—For stowage of two complete firemen’s
A 36/A36M Specification for Carbon Structural Steel
outfits, conforming to all requirements of all sections, figures,
A 276 Specification for Stainless Steel Bars and Shapes
and details of this specification.
A 366/A366M Specification for Commercial Steel (CS)
3.1.3 Type 3—For stowage of one complete fireman’s outfit,
Sheet, Carbon (0.15 Maximum Percent) Cold-Rolled
with locker dimensions in accordance with Figs. 2, 3, and 4
A 513 Specification for Electric-Resistance-Welded Carbon
(dimensions only), and conforming to the requirements of 3.2,
and Alloy Steel Mechanical Tubing
3.3, 4.1, 5.2.4, and Sections 6 and 7 inclusive.
A 563 Specification for Carbon and Alloy Steel Nuts
3.1.4 Type 4—For stowage of two complete firemen’s
B 36 Specification for Brass Plate, Sheet, Strip, and Rolled
6 outfits, with locker dimensions in accordance with Figs. 2, 3,
Bar
and 4 (dimensions only), and conforming to the requirements
B 124 Specification for Copper and Copper Alloy Forging
6 of 3.2, 3.3, 4.1, 5.2.4, and Sections 6 and 7 inclusive.
Rod, Bar, and Shapes
3.2 One complete fireman’s outfit shall consist of the
B 176 Specification for Copper-Alloy Die Castings
following emergency gear (not included in this specification):
2.2 ANSI Standards:
3.2.1 Self-contained breathing apparatus (24 by 14 by 11 in.
B18.1.1 Small Solid Rivets
(610 by 355 by 280 mm)).
B18.6.3 Slotted and Recessed Head Machine Screws and
3.2.2 Recharge air tank (7-in. (180-mm) diameter by 22 in.
Machine Screw Nuts
7 (560 mm) long).
B18.21.1 Lock Washers
3.2.3 Set protective clothing, including helmet, gloves, and
B27.2 Plain Washers
boots.
3.2.4 Lifeline (150 ft (45 m), 18 by 18 by 10 in. (455 by 455
This specification is under the jurisdiction of ASTM Committee F-25 on Ships by 255 mm)).
and Marine Technology and is the direct responsibility of Subcommittee F25.03 on
3.2.5 Three-cell, explosion-proof flashlight with spare cells.
Outfitting.
3.2.6 Flame safety lamp.
Current edition approved Aug. 28, 1987. Published November 1987. Originally
published as F 1018 – 86. Last previous edition F 1018 – 87.
Annual Book of ASTM Standards, Vol 01.04.
3 8
Annual Book of ASTM Standards, Vol 01.05. Available from American Bureau of Shipping, 2 World Trade Center, 106th
Annual Book of ASTM Standards, Vol 01.03. Floor, New York, NY 10048.
5 9
Annual Book of ASTM Standards, Vol 15.08. Available from Steel Structures Painting Council, 4400 5th Ave., Pittsburgh, PA
Annual Book of ASTM Standards, Vol 02.01. 15213.
7 10
Available from American National Standards Institute, 11 W. 42nd St., 13th Available from American Welding Society, 550 N.W. Le Jeune Rd., Miami, FL
Floor, New York, NY 10036. 33135.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
F 1018
3.2.7 Fire axe. 5. Materials and Manufacture
3.3 In addition to the equipment listed in 3.2, each locker
5.1 Materials—Materials shall be as specified in Table 1.
shall contain space for the following (not part of this specifi-
5.2 Manufacture:
cation): 5.2.1 Mandatory dimensions and construction details for
Types 1 and 2 are as depicted in Figs. 1-9.
3.3.1 First-aid kit, (1), (10 by 10 by 7 in. (255 by 255 by 180
5.2.2 Mandatory dimensions for Types 3 and 4 are as shown
mm)).
in Fig. 2, Fig. 3, and Fig. 5, respectively, and applicable details
3.3.2 Spare air tanks, as space allows (see Figs. 2, 3, and 4).
of Sections “A-A’’ and “B-B.’’ Alternative construction details
are permissible.
4. Ordering Information
5.2.3 Construction details depicted in Figs. 4-9, while spe-
4.1 Order using this ASTM designation, year of issue, cifically referring to locker Type 2, shall be adapted to suit
locker type, and finish. locker Type 1.
NOTE 1—1 in. = 25.4 mm.
NOTE 2—Approximately 2-in. high red lettering typical.
FIG. 1 Emergency Gear Stowage Locker—Type 1
F 1018
NOTE 1—1 in. = 25.4 mm.
NOTE 2—Approximately 2-in. high red lettering typical.
FIG. 2 Emergency Gear Stowage Locker—Types 2, 3, and 4
5.2.4 Welded construction, in accordance with ABS Rules 6. Dimensions and Tolerances
for Building and Classing Steel Vessels or AWS D 1.1
6.1 Dimensions are as indicated.
Structural Welding Code shall be used throughout, unless
6.2 Tolerance—6 ⁄16 in. (1.5 mm).
otherwise specified.
F 1018
FIG. 3 Emergency Gear Stowage Locker—Types 2, 3, and 4 (Section “A-A”)
7. Workmanship, Finish, and Appearance 7.3.1 The color shall be specified in the ordering documents.
7.1 Entire assembly shall be free of weld spatter, slag,
8. Keywords
splinters, s
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.