Standard Test Methods of Testing Cellular Glass Insulation Block

SIGNIFICANCE AND USE
From a general standpoint, these test methods outline the particular points which have to be taken into account when applying ASTM standard test methods to the case of cellular glass insulating block.
SCOPE
1.1 These test methods cover the testing of cellular glass insulation block for density, water absorption, compressive strength, flexural strength at ambient temperature; preparation for chemical analysis; and thermal conductivity measurements.  
1.2 The values stated in SI are generally to be regarded as the standard. The SI dimensions are to be used for material supplied in metric sizes. The inch dimensions are to be used for material supplied in inch sizes.  
1.3  This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Apr-2003
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C240-97(2003) - Standard Test Methods of Testing Cellular Glass Insulation Block
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C240–97 (Reapproved 2003)
Standard Test Methods of
1
Testing Cellular Glass Insulation Block
This standard is issued under the fixed designation C240; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 2.2 ISO Standard:
ISO 3951 Sampling Procedure and Charts for Inspection by
1.1 These test methods cover the testing of cellular glass
4
Variables for Percent Nonconforming
insulation block for density, water absorption, compressive
2.3 Military Standard:
strength, flexural strength at ambient temperature; preparation
MIL-I-24244 Specification Insulation Materials with Spe-
forchemicalanalysis;andthermalconductivitymeasurements.
5
cial Corrosion, Chloride, and Fluoride Requirements
1.2 The values stated in SI are generally to be regarded as
2.4 Other Standard:
the standard. The SI dimensions are to be used for material
NRC 1.36 Nonmetallic Thermal Insulation for Austenitic
suppliedinmetricsizes.Theinchdimensionsaretobeusedfor
6
Stainless Steel
material supplied in inch sizes.
1.3 This standard does not purport to address all of the
3. Terminology
safety concerns, if any, associated with its use. It is the
3.1 Definitions—Terminology C168 shall be considered as
responsibility of the user of this standard to establish appro-
applying to the terms considered in these test methods.
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
4. Significance and Use
4.1 From a general standpoint, these test methods outline
2. Referenced Documents
the particular points which have to be taken into account when
2.1 ASTM Standards:
applying ASTM standard test methods to the case of cellular
C165 Test Method for Measuring Compressive Properties
2
glass insulating block.
of Thermal Insulations
2
C168 Terminology Relating to Thermal Insulation
5. Test Methods
C177 Test Method for Steady-State Heat Flux Measure-
5.1 General Sample Preparation—All tests have to be run
ments and Thermal Transmission Properties by Means of
2 on dry specimens. In case of need, the sample must be
the Guarded-Hot-Plate Apparatus
unpacked and stored in a dry place in such a way that all
C203 Test Methods for Breaking Load and Flexural Prop-
2 surfaces are exposed to the ambient air for at least one day
erties of Block-Type Thermal Insulation
before testing.
C303 Test Method for Dimensions and Density of Pre-
2 5.2 Density—DeterminethedensityinaccordancewithTest
formed Block and Broad-Type Thermal Insulation
Method C303. Preferably, the density shall be measured on a
C390 Practice for Sampling andAcceptance of Preformed
2 full block, 450 by 600 mm (18 by 24 in.) by full thickness.
Thermal Insulation Lots
5.2.1 Itshouldbenotedthatdensityisinterestingassuchfor
C518 Test Method for Steady-State Thermal Transmission
2 calculation of insulated equipment load and because it has
Properties by Means of the Heat Flow Meter Apparatus
some influence on the other important properties of cellular
C871 Test Methods for Chemical Analysis of Thermal
glass. But it should not be considered in itself as a criterion for
Insulation Materials for Leachable Chloride, Fluoride,
2 acceptance in the case of cellular glass.
Silicate, and Sodium Ions
5.3 Water Absorption:
D 226 Specification for Asphalt-Saturated Organic Felt
3
Used in Roofing and Waterproofing
1
These test methods are under the jurisdiction of ASTM Committee C16 on
4
Thermal Insulation and are the direct responsibility of Subcommittee C16.32 on Available from American National Standards Institute, 25 W. 43nd St., 4th
Mechanical Properties. Floor, New York, NY 10036.
5
Current edition approved April 10, 2003. Published July 2003. Originally Available from Standardization Documents Order Desk, Bldg. 4, Section D,
approved in 1950. Last previous edition approved in 1997 as C 240–97. 700 Robbins Ave., Philadelphia, PA 19111-5094.
2 6
Annual Book of ASTM Standards, Vol 04.06. Available from Director of Regulatory Standards, USAtomic Energy Commis-
3
Annual Book of ASTM Standards, Vol 04.04. sion, Washington, DC 20545.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C240–97 (2003)
5.3.1 Scope—This test method covers the determination of 5.4 Compressive Strength—Determine the compressive
water absorption of cellular glass insulating blocks by measur- strength in accordance with Test Method C165 Procedure A,
ing the amount of water retained as a result of complete with the following test parameters and specimen preparation
im
...

Questions, Comments and Discussion