ASTM C655-02
(Specification)Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe
Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe
SCOPE
1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts.
1.2 A complete metric companion to Specification C 655 has been developed-Specification C 655M; therefore, no metric equivalents are presented in this specification.
Note 1—Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 655 – 02
Standard Specification for
Reinforced Concrete D-Load Culvert, Storm Drain, and
1
Sewer Pipe
This standard is issued under the fixed designation C 655; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope C 497 Test Methods for Concrete Pipe, Manhole Sections,
5
or Tile
1.1 This specification covers reinforced concrete pipe de-
4
C 595 Specification for Blended Hydraulic Cements
signed for specific D-loads and intended to be used for the
C 618 Specification for Fly Ash and Raw or Calcined
conveyance of sewage, industrial wastes, and storm water and
Natural Pozzolan for Use as a Mineral Admixture in
for the construction of culverts.
3
Concrete
1.2 A complete metric companion to Specification C 655
C 822 Terminology Relating to Concrete Pipe and Related
has been developed—Specification C 655M; therefore, no
5
Products
metric equivalents are presented in this specification.
C 989 Specification for Ground Granulated Blast-Furnace
NOTE 1—Experience has shown that the successful performance of this 3
Slag for Use in Concrete and Mortars
product depends upon the proper selection of the pipe strength, the type of
C 1116 Specification for Fiber-Reinforced Concrete and
bedding and backfill, the care that the installation conforms to the
3
Shotcrete
construction specifications, and provision for adequate inspection at the
6
E 105 Practice for Probability Sampling of Materials
construction site. This specification does not include requirements for
bedding, backfill, the relationship between field load conditions and the
3. Terminology
strength designation of pipe, or durability under unusual environmental
conditions. These requirements should be included in the project specifi-
3.1 Definitions—For definitions of terms relating to con-
cation.
crete pipe, see Terminology C 822.
2. Referenced Documents
4. Basis of Acceptance
2.1 ASTM Standards:
4.1 The acceptability of the pipe design shall be determined
A 82 Specification for Steel Wire, Plain, for Concrete Re-
in accordance with Section 9. After the pipe design has been
2
inforcement
accepted, or if the pipe design has been accepted previously in
A 185 Specification for Steel Welded Wire Reinforcement,
accordance with Section 9, the owner may select and have
2
Plain, for Concrete
applied the basis of acceptance described in either 4.1.1 or
A 496 Specification for Steel Wire, Deformed, for Concrete
4.1.2. Unless designated by the owner at the time of, or before
2
Reinforcement
placing an order, either basis of acceptance shall be permitted.
A 497 Specification for Steel Welded Wire Reinforcement,
4.1.1 Acceptance on the Basis of Pipe Load and Material
2
Deformed, for Concrete
Tests and Inspection of Manufactured Pipe for Defects
A 615/A 615M Specification for Deformed and Plain
—Determine in accordance with Sections 5, 6, 8, and 10.
2
Billet-Steel Bars for Concrete Reinforcement
3
NOTE 2—It is necessary that samples be selected at random. For
C 33 Specification for Concrete Aggregates
4 guidance see Practice E 105.
C 150 Specification for Portland Cement
4.1.2 Acceptance on the Basis of Concrete Compression and
Materials Tests and Inspection of Manufactured Pipe for
Defects—Determine in accordance with Sections 5, 6, 8 and
1
This specification is under the jurisdiction of ASTM Committee C13 on
11.
Concrete Pipe and is the direct responsibility of Subcommittee C13.07 on
4.2 Age for Acceptance—Pipe shall be considered ready for
Acceptance Specifications and Precast Concrete Box Sections.
acceptance when they conform to the requirements.
Current edition approved July 10, 2002. Published October 2002. Originally
published as C 655–70T. Last previous edition C 655–00.
2
Annual Book of ASTM Standards, Vol 01.04.
3 5
Annual Book of ASTM Standards, Vol 04.02. Annual Book of ASTM Standards, Vol 04.05.
4 6
Annual Book of ASTM Standards, Vol 04.01. Annual Book of ASTM Standards, Vol 14.02.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C655–02
5. Design and Manufacturing Data 6.2.1 Mixture—The aggregates shall be sized, graded, pro-
portioned, and mixed with such proportions of cementitious
5.1 The manufacturer shall provide the following informa-
materials and water as will produce a homogeneous concrete
tion regarding the pipe unless waived by the owner:
mixture of such quality that the pipe will conform to the test
5.1.1 Basis of acceptance.
and design require
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.