Standard Test Method for Measurement of Apparent Viscosity of Asphalt-Rubber or Other Asphalt Binders by Using a Rotational Handheld Viscometer

SIGNIFICANCE AND USE
3.1 This test is primarily used for field production control of asphalt-rubber (A-R) and other high-viscosity binders; however, the test can also be used in a laboratory setting.  
3.2 A handheld rotational viscometer is used to measure the apparent viscosity of a completed blend of A-R or high-viscosity binder. A rotor (spindle), turning at constant speed, is inserted in the liquid binder to be measured. The resistance to movement of the spindle (torque) caused by the viscosity of the surrounding liquid is measured using a special mechanism to obtain direct readings in Pa·s or cP.
Note 1: Spindle is generally made of stainless steel, although another metal such as brass could be used.  
3.3 The measured apparent viscosity is used to control the production of the A-R or other high-viscosity binder, to assess the uniformity of the binder produced, or for other related purposes.  
3.4 As the spindle turns in the A-R or other high-viscosity binder, it has a tendency to “drill” into the sample (that is, for A-R, the spindle spins the rubber particles out of the measurement area). Consequently, the apparent viscosity drops to reflect only the liquid phase of the high-viscosity binder. Therefore, the peak viscosity measurement value is recorded to reflect the viscosity of the blended material.
SCOPE
1.1 The use of high-viscosity asphalt binders like asphalt-rubber is becoming more common in the United States and worldwide. Specifications such as Specification D6114 note the need for field control of the apparent viscosity and require the use of a field production rotational viscometer. The testing of asphalt-rubber binder for use in asphalt-rubber hot mix and for asphalt-rubber membrane is necessary to ensure consistent mix properties that will ensure good performance of these materials. Logistics of field applications limits the use of conventional laboratory controls and testing equipment. This test, using a handheld rotational viscometer, can be conducted in either the field or laboratory to determine the apparent viscosity of asphalt-rubber and other high-viscosity binders for field production control and to assess the uniformity of the binder produced, or for other related purposes.  
1.2 Asphalt-rubber binder consists of a blend of paving grade asphalt cement and crumb rubber as described in Specification D6114. Other high-viscosity asphalt binders may consist of asphalts modified with polymer or fiber, or both. Testing is performed following the specified reaction time, if any, within the production process. Control of the raw materials is separate from the test.  
1.3 The values stated in SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; each system shall be used independently of the other. Combining values from the two systems may result in noncompliance with the standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
31-May-2018
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D7741/D7741M-18 - Standard Test Method for Measurement of Apparent Viscosity of Asphalt-Rubber or Other Asphalt Binders by Using a Rotational Handheld Viscometer
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D7741/D7741M-18 - Standard Test Method for Measurement of Apparent Viscosity of Asphalt-Rubber or Other Asphalt Binders by Using a Rotational Handheld Viscometer
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D7741/D7741M − 18
Standard Test Method for
Measurement of Apparent Viscosity of Asphalt-Rubber or
Other Asphalt Binders by Using a Rotational Handheld
1
Viscometer
This standard is issued under the fixed designation D7741/D7741M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.5 This international standard was developed in accor-
dance with internationally recognized principles on standard-
1.1 The use of high-viscosity asphalt binders like asphalt-
ization established in the Decision on Principles for the
rubber is becoming more common in the United States and
Development of International Standards, Guides and Recom-
worldwide.SpecificationssuchasSpecificationD6114notethe
mendations issued by the World Trade Organization Technical
need for field control of the apparent viscosity and require the
Barriers to Trade (TBT) Committee.
use of a field production rotational viscometer. The testing of
asphalt-rubber binder for use in asphalt-rubber hot mix and for
2. Referenced Documents
asphalt-rubber membrane is necessary to ensure consistent mix
2
2.1 ASTM Standards:
properties that will ensure good performance of these materi-
D6114 Specification for Asphalt-Rubber Binder
als. Logistics of field applications limits the use of conven-
tional laboratory controls and testing equipment. This test,
3. Significance and Use
using a handheld rotational viscometer, can be conducted in
3.1 This test is primarily used for field production control of
eitherthefieldorlaboratorytodeterminetheapparentviscosity
of asphalt-rubber and other high-viscosity binders for field asphalt-rubber (A-R) and other high-viscosity binders;
however, the test can also be used in a laboratory setting.
production control and to assess the uniformity of the binder
produced, or for other related purposes.
3.2 Ahandheld rotational viscometer is used to measure the
apparent viscosity of a completed blend of A-R or high-
1.2 Asphalt-rubber binder consists of a blend of paving
viscosity binder.Arotor (spindle), turning at constant speed, is
grade asphalt cement and crumb rubber as described in
inserted in the liquid binder to be measured. The resistance to
Specification D6114. Other high-viscosity asphalt binders may
movementofthespindle(torque)causedbytheviscosityofthe
consist of asphalts modified with polymer or fiber, or both.
Testing is performed following the specified reaction time, if surrounding liquid is measured using a special mechanism to
obtain direct readings in Pa·s or cP.
any, within the production process. Control of the raw materi-
als is separate from the test.
NOTE 1—Spindle is generally made of stainless steel, although another
metal such as brass could be used.
1.3 The values stated in SI units or inch-pound units are to
be regarded separately as standard. The values stated in each
3.3 The measured apparent viscosity is used to control the
systemmaynotbeexactequivalents;eachsystemshallbeused
production of the A-R or other high-viscosity binder, to assess
independently of the other. Combining values from the two
the uniformity of the binder produced, or for other related
systems may result in noncompliance with the standard.
purposes.
1.4 This standard does not purport to address all of the
3.4 As the spindle turns in the A-R or other high-viscosity
safety concerns, if any, associated with its use. It is the
binder, it has a tendency to “drill” into the sample (that is, for
responsibility of the user of this standard to establish appro-
A-R, the spindle spins the rubber particles out of the measure-
priate safety, health, and environmental practices and deter-
ment area). Consequently, the apparent viscosity drops to
mine the applicability of regulatory limitations prior to use.
reflect only the liquid phase of the high-viscosity binder.
Therefore, the peak viscosity measurement value is recorded to
reflect the viscosity of the blended material.
1
This test method is under the jurisdiction of ASTM Committee D04 on Road
and Paving Materials and is the direct responsibility of Subcommittee D04.44 on
2
Rheological Tests. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved June 1, 2018. Published June 2018. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 2011. Last previous edition approved in 2017 as D7741/D7741M – 11 Standards volume information, refer to the standard’s
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D7741/D7741M − 11 (Reapproved 2017) D7741/D7741M − 18
Standard Test Method for
Measurement of Apparent Viscosity of Asphalt-Rubber or
Other Asphalt Binders by Using a Rotational Handheld
1
Viscometer
This standard is issued under the fixed designation D7741/D7741M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 The use of high-viscosity asphalt binders like asphalt-rubber is becoming more common in the United States and worldwide.
Specifications such as Specification D6114 note the need for field control of the apparent viscosity and require the use of a field
production rotational viscometer. The testing of asphalt-rubber binder for use in asphalt-rubber hot mix and for asphalt-rubber
membrane is necessary to ensure consistent mix properties that will ensure good performance of these materials. Logistics of field
applications limits the use of conventional laboratory controls and testing equipment. This test, using a handheld rotational
viscometer, can be conducted in either the field or laboratory to determine the apparent viscosity of asphalt-rubber and other
high-viscosity binders for field production control and to assess the uniformity of the binder produced, or for other related
purposes.
1.2 Asphalt-rubber binder consists of a blend of paving grade asphalt cement and crumb rubber as described in Specification
D6114. Other high-viscosity asphalt binders may consist of asphalts modified with polymer or fiber, or both. Testing is performed
following the specified reaction time, if any, within the production process. Control of the raw materials is separate from the test.
1.3 The values stated in SI units or inch-pound units are to be regarded separately as standard. The values stated in each system
may not be exact equivalents; each system shall be used independently of the other. Combining values from the two systems may
result in noncompliance with the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D6114 Specification for Asphalt-Rubber Binder
3. Significance and Use
3.1 This test is primarily used for field production control of asphalt-rubber (A-R) and other high-viscosity binders; however,
the test can also be used in a laboratory setting.
1
This test method is under the jurisdiction of ASTM Committee D04 on Road and Paving Materials and is the direct responsibility of Subcommittee D04.44 on Rheological
Tests.
Current edition approved June 1, 2017June 1, 2018. Published June 2017June 2018. Originally approved in 2011. Last previous edition approved in 20122017 as
ɛ1
D7741/D7741M – 11 (2017). . DOI: 10.1520/D7741_D7741M-11R17. 10.1520/D7741_D7741M-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D7741/D7741M − 18
3.2 A handheld rotational viscometer is used to measure the apparent viscosity of a completed blend of A-R or high-viscosity
binder. A rotor (spindle), turning at constant speed, is inserted in the liquid binder to be measured. The resistance to movement
of the spindle (torque) caused by the viscosity of the surrounding li
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.