ASTM F2057-00
(Specification)Standard Safety Specification for Chests, Door Chests, and Dressers
Standard Safety Specification for Chests, Door Chests, and Dressers
SCOPE
1.1 This safety specification is intended to reduce injuries and deaths of children from hazards associated with tipover of clothing storage units.
1.2 This safety specification covers chests, drawer chests, chests of drawers, dressers, and bureaus only (see Section 2).
1.3 This safety specification does not cover shelving units, such as bookcases or entertainment centers, night stands, or under-bed drawer storage units.
1.4 This safety specification does not cover any items 30 in. or less in height.
1.5 This safety specification is intended to cover children up to and including age five.
1.6 This safety specification replaces PS 110-98.
1.7 The following safety hazards caveat pertains only to the test procedure portion, Section 4, of this safety specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F 2057 – 00
Standard Safety Specification for
1
Chests, Door Chests, and Dressers
This standard is issued under the fixed designation F 2057; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
The Consumer Product Safety Commission (CPSC) estimates that there were 8100 emergency room
treated injuries associated with the tipover of furniture in 1994.
In addition, the CPSC received reports of about six deaths each year associated with furniture
tipover. Approximately two thirds of the deaths were said to have involved items with drawers, such
as dressers, bureaus, and chests of drawers. Approximately 80 % were to children under the age of
five.
1. Scope more of the following: drawers, doors, stationary shelves,
adjustable shelves, or pull-out shelves arranged in varying
1.1 This safety specification is intended to reduce injuries
configurations.
and deaths of children from hazards associated with tipover of
2.1.2 door chest, n—a furniture item intended for the
clothing storage units.
storage of clothing and consisting of a case with drawers at the
1.2 This safety specification covers chests, drawer chests,
bottom of the unit and drawer or permanent shelves covered by
chests of drawers, dressers, and bureaus only (see Section 2).
two doors at the top of the case.
1.3 This safety specification does not cover shelving units,
2.1.3 dresser, n—a furniture item intended for the storage of
such as bookcases or entertainment centers, night stands, or
clothing and consisting of up to nine drawers usually arranged
under-bed drawer storage units.
in groups three high and three wide. Dimensions are usually 65
1.4 This safety specification does not cover any items 30 in.
to 72 in. wide and 30 to 35 in. high.
or less in height.
2.1.4 operational sliding length, n—the total length of the
1.5 This safety specification is intended to cover children up
2 shortest side of the drawer side, or, if the drawer slide has a
to and including age five.
stop built in, the length of the slide to the stop.
1.6 This safety specification replaces PS 110–98.
2.1.5 tipover, n—the event at which a furniture unit pivots
1.7 The following safety hazards caveat pertains only to the
forward to a point beyond which the unit continues to fall.
test procedure portion, Section 4, of this safety specification:
This standard does not purport to address all of the safety
3. Performance Requirements
concerns, if any, associated with its use. It is the responsibility
3.1 With the unit empty, test the unit in accordance with 4.1
of the user of this standard to establish appropriate safety and
and 4.2.
health practices and determine the applicability of regulatory
3.2 During the test, the unit shall not tip over or be
limitations prior to use.
supported only by an opened drawer, opened door, or opened
2. Terminology or unopened flap.
3.3 If a failed component prohibits the completion of the
2.1 Definitions of Terms Specific to This Standard:
test, the unit is to have the failed component repaired or
2.1.1 chest, n—a furniture item intended for the storage of
replaced to the original specifications, or the unit replaced and
clothing typical of bedroom furniture and containing one or
the test repeated.
1 4. Test Procedure
This safety specification is under the jurisdiction of ASTM Committee F15 on
Consumer Productsand is the direct responsibility of Subcommittee F15.42 on
4.1 Stability of Unloaded Unit:
Furniture Tipover.
Approved Sept. 10, 2000. Published November 2000.
2
The majority (approximately 80 %) of deaths relate to children 5 years or
younger (see Introduction).
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
F 2057
4.1.1 Position the unit on a level flat surface composed of
1
either concrete, wood flooring, or ⁄8 in. vinyl over concrete. If
the unit has leveling glides, these glides shall be installed and
be in contact with the floor, and the units shall be level during
testing.
4.1.2 Open all doors to 90° (Fig. 1) and extend all drawers
and pullout shelves to two thirds of their operational sliding
length or to the stop, whichever is shorter (2.1.4 and Fig. 2).
Open flaps or dropfronts to their horizontal position or as near
horizontal as possible.
4.2 Stability with Load:
4.2.1 Position the unit on a level flat surface composed of
1
either concrete, wood flooring, or ⁄8 in. vinyl over concrete. If
the unit has leveling glides, these glides shall be installed and
be in contact with the floor, and the units shall
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.