Standard Specification for Nonvulcanized (Uncured) Rubber Sheet Used as Roof Flashing

ABSTRACT
This specification covers nonvulcanized (uncured) rubber sheet made of ethylene-propylene-diene terpolymer (EPDM) or polychloroprene (CR) intended for use as watertight roof flashing exposed to the weather. In-place roof system design criteria such as fire resistance, field seaming strength, material compatibility, and uplift resistance, among others, are beyond the scope of this specification. The flashing material shall be formulated from the appropriate polymer type and other compounding ingredients, and shall be capable of being bonded to itself, to the roofing membrane, and to substrate for making watertight field splices and repairs. Property requirements for flashing before vulcanization include thickness, Green strength modulus, ultimate elongation, shelf stability, vulcanizability, tensile strength and set, dimensional stability, and weatherability. Consequently, the property requirements for flashing after vulcanization includes tensile strength and set, elongation, tear resistance, brittle point, ozone resistance, air oven heat aging, water absorption and weight change, linear dimension change, and weatherability.
SCOPE
1.1 This specification covers nonvulcanized (uncured) rubber sheet made of EPDM (ethylene-propylene-diene terpolymer) or CR (polychloroprene) intended for use as watertight roof flashing exposed to the weather.
1.2 The tests and property limits used to characterize these flashing materials are specific for each classification and are minimum values to make the product fit for its intended purpose.
1.3 SI units shall be used in referee decisions.
1.4 In-place roof system design criteria, such as fire resistance, field seaming strength, material compatibility, and uplift resistance, among others, are beyond the scope of this specification.
The following precautionary caveat pertains to the test methods portion only, Section 8, of this specification: This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Nov-2006
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D4811-06 - Standard Specification for Nonvulcanized (Uncured) Rubber Sheet Used as Roof Flashing
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D4811 −06
StandardSpecification for
Nonvulcanized (Uncured) Rubber Sheet Used as Roof
1
Flashing
This standard is issued under the fixed designation D4811; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D573Test Method for Rubber—Deterioration in an Air
Oven
1.1 This specification covers nonvulcanized (uncured) rub-
D624Test Method for Tear Strength of Conventional Vul-
ber sheet made of EPDM (ethylene-propylene-diene terpoly-
canized Rubber and Thermoplastic Elastomers
mer) or CR (polychloroprene) intended for use as watertight
D1079Terminology Relating to Roofing and Waterproofing
roof flashing exposed to the weather.
D1149TestMethodsforRubberDeterioration—Crackingin
1.2 The tests and property limits used to characterize these
an Ozone Controlled Environment
flashing materials are specific for each classification and are
D1204Test Method for Linear Dimensional Changes of
minimum values to make the product fit for its intended
Nonrigid Thermoplastic Sheeting or Film at Elevated
purpose.
Temperature
1.3 SI units shall be used in referee decisions. D1418 Practice for Rubber and Rubber Latices—
Nomenclature
1.4 In-place roof system design criteria, such as fire
D2137TestMethodsforRubberProperty—BrittlenessPoint
resistance, field seaming strength, material compatibility, and
of Flexible Polymers and Coated Fabrics
uplift resistance, among others, are beyond the scope of this
D3182PracticeforRubber—Materials,Equipment,andPro-
specification.
cedures for Mixing Standard Compounds and Preparing
1.5 The following precautionary caveat pertains to the test
Standard Vulcanized Sheets
methods portion only, Section 8, of this specification:This
G151PracticeforExposingNonmetallicMaterialsinAccel-
standard may involve hazardous materials, operations, and
erated Test Devices that Use Laboratory Light Sources
equipment. This standard does not purport to address the
G154PracticeforOperatingFluorescentLightApparatusfor
safety concerns associated with its use. It is the responsibility
UV Exposure of Nonmetallic Materials
of the user of this standard to establish appropriate safety and
G155Practice for Operating XenonArc LightApparatus for
health practices and determine the applicability of regulatory
Exposure of Non-Metallic Materials
limitations prior to use.
3. Classification
2. Referenced Documents
3.1 The following types are used to identify the principal
2
2.1 ASTM Standards: polymer components of the flashing material (see Note 1):
D412TestMethodsforVulcanizedRubberandThermoplas-
3.1.1 Type I—Ethylene-Propylene-Diene Terpolymer
tic Elastomers—Tension (EPDM).
D471Test Method for Rubber Property—Effect of Liquids
3.1.2 Type II—Chloroprene Polymer (CR).
D518 Test Method for Rubber Deterioration—Surface
NOTE 1—For definitions of polymer types, see Practice D1418. For
3
Cracking (Withdrawn 2007)
definitions of terms related to roofing, see Terminology D1079.
3.2 The following classes describe the ability to vulcanize
1
on the roof:
This specification is under the jurisdiction of ASTM Committee D08 on
RoofingandWaterproofingandisthedirectresponsibilityofSubcommitteeD08.18
3.2.1 Class V—Vulcanizing.
on Nonbituminous Organic Roof Coverings.
3.2.2 Class NV—Nonvulcanizing.
Current edition approved Dec. 1, 2006. Published January 2007. Originally
approved in 1990. Last previous edition approved in 2004 as D4811–04. DOI:
NOTE 2—Class V compounds continue to vulcanize (that is, cure) after
10.1520/D4811-06.
emplacement on the roof. Class NV indicates non-vulcanizable com-
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
pounds.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
4. Materials and Manufacture
the ASTM website.
3
4.1 The flashing material shall be formulated from the
The last approved version of this historical standard is referenced on
www.astm.org. appropriate polymer type and other compounding ingredients.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D4811−06
TABLE 2 Property Requirements for Flashing After Vulcanization
The principal polymer in the flashing material shall be one of
those listed in 3.1 and greater than 95% of the total polymer. Type I, Type II,
Class V Class V
4.2 The flashing material shall be capable of being bonded
Vulcanization, at 160°C (320°F), min 20 ± 2 20 ± 2
to itself, to the roofing membrane, and to substrate for making
Tensile Stren
...

Questions, Comments and Discussion