Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings

SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining system, and a form of marking for large diameters, 18 to 48 in. poly(vinyl chloride) (PVC) sewer pipe and fittings with integral bell elastomeric seal joints and smooth inner walls.
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for nonpressure drainage of sewage and surface water. Pipe and fittings produced to this specification should be installed in accordance with Practice D 2321. Industrial waste disposal lines should be installed only with the specific approval of the governing code authority since temperatures in excess of 140°F (60°C) and chemicals not commonly found in drains and sewers may be encountered.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are provided for information purposes only.
The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability or regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Oct-2006
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F679-06a - Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: F 679 – 06a
Standard Specification for
Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity
1
Sewer Pipe and Fittings
This standard is issued under the fixed designation F679; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope D1600 Terminology for Abbreviated Terms Relating to
Plastics
1.1 This specification covers requirements and test methods
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
for materials, dimensions, workmanship, flattening resistance,
Compounds and Chlorinated Poly(Vinyl Chloride)
impact resistance, pipe stiffness, extrusion quality, joining
(CPVC) Compounds
system, and a form of marking for large diameters, 18 to 48 in.
D2122 Test Method for Determining Dimensions of Ther-
poly(vinyl chloride) (PVC) sewer pipe and fittings with inte-
moplastic Pipe and Fittings
gral bell elastomeric seal joints and smooth inner walls.
D2152 Test Method for Adequacy of Fusion of Extruded
1.2 The requirements of this specification are intended to
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
provide pipe and fittings suitable for nonpressure drainage of
Acetone Immersion
sewage and surface water. Pipe and fittings produced to this
D2321 Practice for Underground Installation of Thermo-
specification should be installed in accordance with Practice
plastic Pipe for Sewers and Other Gravity-Flow Applica-
D2321.
tions
NOTE 1—Industrial waste disposal lines should be installed only with
D2412 TestMethodforDeterminationofExternalLoading
thespecificapprovalofthegoverningcodeauthoritysincetemperaturesin
Characteristics of Plastic Pipe by Parallel-Plate Loading
excess of 140°F (60°C) and chemicals not commonly found in drains and
D2444 Test Method for Determination of the Impact Re-
sewers may be encountered.
sistance of Thermoplastic Pipe and Fittings by Means of a
1.3 The values stated in inch-pound units are to be regarded
Tup (Falling Weight)
as the standard. The values in parentheses are provided for
D2564 Specification for Solvent Cements for Poly(Vinyl
information purposes only.
Chloride) (PVC) Plastic Piping Systems
1.4 The following precautionary caveat pertains only to the
D2855 Practice for Making Solvent-Cemented Joints with
test method portion, Section 7, of this specification: This
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
standard does not purport to address all of the safety problems,
D3212 Specification for Joints for Drain and Sewer Plastic
if any, associated with its use. It is the responsibility of the user
Pipes Using Flexible Elastomeric Seals
of this standard to establish appropriate safety and health
F402 Practice for Safe Handling of Solvent Cements,
practices and determine the applicability or regulatory limita-
Primers,andCleanersUsedforJoiningThermoplasticPipe
tions prior to use.
and Fittings
F412 Terminology Relating to Plastic Piping Systems
2. Referenced Documents
F477 Specification for Elastomeric Seals (Gaskets) for
2
2.1 ASTM Standards:
Joining Plastic Pipe
D618 Practice for Conditioning Plastics for Testing
2.2 Federal Standard:
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved Nov. 1, 2006. Published November 2006. Originally
approved in 1980. Last previous edition approved in 2006 as F679–06.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F 679 – 06a
TABLE 1 Pipe Dimensions and Minimum Pipe Stiffness
Nominal Pipe Average Outside Tolerance on Average Min Wall Thickness Min Pipe Stiffness
Size Diameter Outside Diameter
in. in. (mm) in. (mm) in. (mm) psi kPa
18 18.701 (475) 60.028 (60.71) 0.499 (12.7) 46 (320)
21 22.047 (560) 60.033 (60.84) 0.588 (14.9) 46 (320)
24 24.803 (630) 60.037 (60.94) 0.661 (15.5) 46 (320)
27 27.953 (710) 60.042 (61.07) 0.745 (18.9) 46 (320)
30 CIOD 32.000 (813) 60.040 (61.02) 0.853 (21.67) 46 (320)
36 CIOD 38.300 (973) 60.050 (61.27) 1.021 (25.93) 46 (320)
42 CIOD 44.500 (1130) 60.060 (61.52) 1.187 (30.15) 46 (320)
48 CIOD 50.800 (1290) 60.075 (61.90) 1.355 (34.42) 46 (320)
18 18.701 (475) 60.028 (60.71) 0.671 (17.0) 115 (790)
21 22.047 (560) 60.033 (60.84) 0.791 (20.1) 115 (790)
24 24.803
...