Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings

ABSTRACT
This specification covers requirements and test methods for poly(vinyl chloride) (PVC) large-diameter plastic gravity sewer pipe and fittings. Pipe requirements include workmanship, pipe dimensions, flattening resistance, impact resistance, pipe stiffness, gaskets requirements, joint tightness, extrusion quality, joining system, and markings. Test procedures shall include referee testing, quality control tests, test conditions, flattening tests, impact resistance, pipe stiffness, and acetone immersion test. Retest, rejection, inspection, certification, marking, delivery, and quality assurance shall conform to the requirements of this specification.
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining system, and a form of marking for large diameters, 18 to 48 in. poly(vinyl chloride) (PVC) sewer pipe and fittings with integral bell elastomeric seal joints and smooth inner walls.  
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for nonpressure drainage of sewage and surface water. Pipe and fittings produced to this specification should be installed in accordance with Practice D 2321.
Note 1—Industrial waste disposal lines should be installed only with the specific approval of the governing code authority since temperatures in excess of 140°F (60°C) and chemicals not commonly found in drains and sewers may be encountered.  
1.3 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are provided for information purposes only.  
1.4 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability or regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
29-Feb-2008
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F679-08 - Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F679-08 - Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F679 −08 AnAmerican National Standard
Standard Specification for
Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity
1
Sewer Pipe and Fittings
ThisstandardisissuedunderthefixeddesignationF679;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* D1784Specification for Rigid Poly(Vinyl Chloride) (PVC)
Compounds and Chlorinated Poly(Vinyl Chloride)
1.1 This specification covers requirements and test methods
(CPVC) Compounds
for materials, dimensions, workmanship, flattening resistance,
D2122Test Method for Determining Dimensions of Ther-
impact resistance, pipe stiffness, extrusion quality, joining
moplastic Pipe and Fittings
system, and a form of marking for large diameters, 18 to 48 in.
D2152Test Method for Adequacy of Fusion of Extruded
poly(vinyl chloride) (PVC) sewer pipe and fittings with inte-
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
gral bell elastomeric seal joints and smooth inner walls.
Acetone Immersion
1.2 The requirements of this specification are intended to
D2321PracticeforUndergroundInstallationofThermoplas-
provide pipe and fittings suitable for nonpressure drainage of
tic Pipe for Sewers and Other Gravity-Flow Applications
sewage and surface water. Pipe and fittings produced to this
D2412Test Method for Determination of External Loading
specification should be installed in accordance with Practice
Characteristics of Plastic Pipe by Parallel-Plate Loading
D2321.
D2444Test Method for Determination of the Impact Resis-
tance of Thermoplastic Pipe and Fittings by Means of a
NOTE 1—Industrial waste disposal lines should be installed only with
thespecificapprovalofthegoverningcodeauthoritysincetemperaturesin
Tup (Falling Weight)
excess of 140°F (60°C) and chemicals not commonly found in drains and
D2564Specification for Solvent Cements for Poly(Vinyl
sewers may be encountered.
Chloride) (PVC) Plastic Piping Systems
1.3 The values stated in inch-pound units are to be regarded
D2855Practice for Making Solvent-Cemented Joints with
as the standard. The values in parentheses are provided for
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
information purposes only.
D3212Specification for Joints for Drain and Sewer Plastic
Pipes Using Flexible Elastomeric Seals
1.4 The following precautionary caveat pertains only to the
F402 Practice for Safe Handling of Solvent Cements,
test method portion, Section 7, of this specification: This
Primers, and Cleaners Used for Joining Thermoplastic
standard does not purport to address all of the safety problems,
Pipe and Fittings
if any, associated with its use. It is the responsibility of the user
F412Terminology Relating to Plastic Piping Systems
of this standard to establish appropriate safety and health
F477Specification for Elastomeric Seals (Gaskets) for Join-
practices and determine the applicability or regulatory limita-
ing Plastic Pipe
tions prior to use.
2.2 Federal Standard:
3
2. Referenced Documents
Fed. Std. No. 123Marking for Shipment (Civil Agencies)
2
2.1 ASTM Standards:
2.3 Military Standard:
3
D618Practice for Conditioning Plastics for Testing
MIL-STD-129Marking for Shipment and Storage
D1600TerminologyforAbbreviatedTermsRelatingtoPlas-
tics
3. Terminology
3.1 Definitions:
3.1.1 General—Definitions used in the specification are in
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
accordance with Terminology F412, unless otherwise indi-
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
cated.Theabbreviationforpoly(vinylchloride)pipeisPVC,in
Current edition approved March 1, 2008. Published March 2008. Originally
accordance with Terminology D1600.
approved in 1980. Last previous edition approved in 2006 as F679–06a. DOI:
10.1520/F0679-08.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from Standardization Documents, Order Desk, Bldg. 4, Section D,
the ASTM website. 700 Robbins Ave., Philadelphia, PA 19111-5094.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F679−08
TABLE 1 Pipe Dimensions and Minimum Pipe Stiffness
Nominal Pipe Average Outside Tolerance on Average Min Wall Thickness Min Pipe Stiffness
Size Diameter Outside Diameter
in. in. (mm) in. (mm) in. (mm) psi kPa
18 18.701 (475) ±0.028 (±0.71) 0.499 (12.7) 46 (320)
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation:F679–06a Designation: F 679 – 08
Standard Specification for
Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity
1
Sewer Pipe and Fittings
This standard is issued under the fixed designation F679; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance,
impact resistance, pipe stiffness, extrusion quality, joining system, and a form of marking for large diameters, 18 to 48 in.
poly(vinyl chloride) (PVC) sewer pipe and fittings with integral bell elastomeric seal joints and smooth inner walls.
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for nonpressure drainage of sewage
and surface water. Pipe and fittings produced to this specification should be installed in accordance with Practice D2321.
NOTE 1—Industrialwastedisposallinesshouldbeinstalledonlywiththespecificapprovalofthegoverningcodeauthoritysincetemperaturesinexcess
of 140°F (60°C) and chemicals not commonly found in drains and sewers may be encountered.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are provided for
information purposes only.
1.4 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard
does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety and health practices and determine the applicability or regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone
Immersion
D2321 Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 TestMethodforDeterminationoftheImpactResistanceofThermoplasticPipeandFittingsbyMeansofaTup(Falling
Weight)
D2564 Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems
D2855 Practice for Making Solvent-Cemented Joints with Poly(Vinyl Chloride) (PVC) Pipe and Fittings
D3212 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals
F402 Practice for Safe Handling of Solvent Cements, Primers, and Cleaners Used for JoiningThermoplastic Pipe and Fittings
F412 Terminology Relating to Plastic Piping Systems
F477 Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe
2.2 Federal Standard:
3
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
2.3 Military Standard:
3
MIL-STD-129 Marking for Shipment and Storage
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved Nov.March 1, 2006.2008. Published November 2006.March 2008. Originally approved in 1980. Last previous edition approved in 2006 as
F679–06a.
2
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from Standardization Documents, Order Desk, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5094.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F679–08
3. Terminology
3.1 Definitions:
3.1.1 General— Definitions used in the specification are in accordance with Terminology F412, unless otherwise indicated.
The abbreviation for poly(vinyl chl
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.