Standard Performance Specification for Flame Resistant and Arc Rated Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Electric Arc and Related Thermal Hazards

ABSTRACT
This performance specification covers the design characteristics and associated test methods that relate specifically to the flame resistance of textile materials used in the fabrication of basic protection level occupational apparel worn by electrical workers who are exposed to momentary electric arc and related thermal hazards such as exposure to open flame and radiant heat. When evaluated in accordance with the test procedures enlisted herein, knit fabrics and woven fabrics of different fabric weights shall conform to individually specified values of the following properties: colorfastness such as laundering shade change, dry-cleaning shade change, and dimensional change; initial flammability characteristics and flammability characteristics after 25 washes/dry-cleaning such as char length and afterflame time; and arc test rating. Knit fabrics shall additionally be tested and adhere accordingly to bursting strength characteristics. Conversely, woven fabrics shall also be tested and adhere accordingly to breaking load, tear resistance, and seam slippage characteristics.
SCOPE
1.1 This performance specification covers the flame resistance of textile materials to be used for wearing apparel for use by electrical workers exposed to momentary electric arc and related thermal hazards.  
Note 1—This performance specification does not cover coated fabrics commonly used in rainwear.
Note 2—At present, a bench scale arc test for laboratory use is not available. It is the intent of the committee to continue the search for an acceptable laboratory test based on either an electric arc exposure or an acceptable alternative, which will form the basis of a modification of this performance specification.  
1.2 Materials used for basic protection levels are covered.
1.3 Protective properties relate to thermal exposure from momentary arc and associated exposure to open flame and radiant heat. (See Appendix X1.)
1.4 This performance specification covers wearing apparel design characteristics that relate specifically to protection from exposure to momentary electric arc and that relate to the utility of the wearing apparel.
Note 3—A number of other thermal test methods are under consideration and development and, when evaluated and proved effective by Committee F18, will be incorporated in either this performance specification or an appropriate alternative test method or specification.  
1.5 This standard should be used to evaluate and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions. It should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions.  
1.5.1 The results of this evaluation may be used as elements of a fire-risk assessment that takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use.  
1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.  
1.7 The following precautionary caveat pertains only to the test methods portion, Section 7, of this performance specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Sep-2010
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1506-10a - Standard Performance Specification for Flame Resistant and Arc Rated Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Electric Arc and Related Thermal Hazards
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F1506-10a - Standard Performance Specification for Flame Resistant and Arc Rated Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Electric Arc and Related Thermal Hazards
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F1506 −10a
StandardPerformance Specification for
Flame Resistant and Arc Rated Textile Materials for Wearing
Apparel for Use by Electrical Workers Exposed to
1
Momentary Electric Arc and Related Thermal Hazards
This standard is issued under the fixed designation F1506; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.6 The values stated in SI units are to be regarded as the
standard. The values given in parentheses are for information
1.1 This performance specification covers the flame resis-
only.
tance of textile materials to be used for wearing apparel for use
1.7 The following precautionary caveat pertains only to the
by electrical workers exposed to momentary electric arc and
test methods portion, Section 7, of this performance specifica-
related thermal hazards.
tion: This standard does not purport to address all of the safety
NOTE 1—This performance specification does not cover coated fabrics
concerns, if any, associated with its use. It is the responsibility
commonly used in rainwear.
of the user of this standard to establish appropriate safety and
NOTE 2—At present, a bench scale arc test for laboratory use is not
available. It is the intent of the committee to continue the search for an health practices and determine the applicability of regulatory
acceptable laboratory test based on either an electric arc exposure or an
limitations prior to use.
acceptable alternative, which will form the basis of a modification of this
performance specification.
2. Referenced Documents
1.2 Materials used for basic protection levels are covered.
2
2.1 ASTM Standards:
1.3 Protective properties relate to thermal exposure from
D123 Terminology Relating to Textiles
momentary arc and associated exposure to open flame and
D434 Test Method for Resistance to Slippage of Yarns in
radiant heat. (See Appendix X1.)
Woven Fabrics Using a Standard Seam (Withdrawn
3
2003)
1.4 This performance specification covers wearing apparel
D1424 Test Method for Tearing Strength of Fabrics by
design characteristics that relate specifically to protection from
Falling-Pendulum (Elmendorf-Type) Apparatus
exposure to momentary electric arc and that relate to the utility
D2262 Test Method for Tearing Strength of Woven Fabrics
of the wearing apparel.
by the Tongue (Single Rip) Method (Constant-Rate-of-
NOTE 3—A number of other thermal test methods are under consider-
3
Traverse Tensile Testing Machine) (Withdrawn 1995)
ation and development and, when evaluated and proved effective by
D2724 Test Methods for Bonded, Fused, and Laminated
Committee F18, will be incorporated in either this performance specifi-
Apparel Fabrics
cation or an appropriate alternative test method or specification.
D3786 Test Method for Bursting Strength of Textile
1.5 This standard should be used to evaluate and describe
Fabrics—Diaphragm Bursting Strength Tester Method
the properties of materials, products, or assemblies in response
D5034 TestMethodforBreakingStrengthandElongationof
to heat and flame under controlled laboratory conditions. It
Textile Fabrics (Grab Test)
should not be used to describe or appraise the fire hazard or
D6413 Test Method for Flame Resistance of Textiles (Ver-
fire risk of materials, products, or assemblies under actual fire
tical Test)
conditions.
F1449 Guide for Industrial Laundering of Flame, Thermal,
1.5.1 The results of this evaluation may be used as elements
and Arc Resistant Clothing
of a fire-risk assessment that takes into account all of the
F1959/F1959M TestMethodforDeterminingtheArcRating
factors that are pertinent to an assessment of the fire hazard of
of Materials for Clothing
a particular end use.
1 2
This performance specification is under the jurisdiction of ASTM Committee For referenced ASTM standards, visit the ASTM website, www.astm.org, or
F18 on Electrical Protective Equipment for Workers and is the direct responsibility contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
of Subcommittee F18.65 on Wearing Apparel. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Oct. 1, 2010. Published October 2010. Originally the ASTM website.
3
approved in 1994. Last previous edition approved in 2010 as F1506–10. DOI: The last approved version of this historical standard is referenced on
10.1520/F1506-10A. www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1506−10a
4
2.2 AATCC Test Methods: 3.2.7 breakopen thresho
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:F1506–10 Designation: F1506 – 10a
Standard Performance Specification for
Flame Resistant and Arc Rated Textile Materials for Wearing
Apparel for Use by Electrical Workers Exposed to
1
Momentary Electric Arc and Related Thermal Hazards
This standard is issued under the fixed designation F1506; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This performance specification covers the flame resistance of textile materials to be used for wearing apparel for use by
electrical workers exposed to momentary electric arc and related thermal hazards.
NOTE 1—This performance specification does not cover coated fabrics commonly used in rainwear.
NOTE 2—At present, a bench scale arc test for laboratory use is not available. It is the intent of the committee to continue the search for an acceptable
laboratory test based on either an electric arc exposure or an acceptable alternative, which will form the basis of a modification of this performance
specification.
1.2 Materials used for basic protection levels are covered.
1.3 Protectivepropertiesrelatetothermalexposurefrommomentaryarcandassociatedexposuretoopenflameandradiantheat.
(See Appendix X1.)
1.4 This performance specification covers wearing apparel design characteristics that relate specifically to protection from
exposure to momentary electric arc and that relate to the utility of the wearing apparel.
NOTE 3—A number of other thermal test methods are under consideration and development and, when evaluated and proved effective by Committee
F18, will be incorporated in either this performance specification or an appropriate alternative test method or specification.
1.5 This standard should be used to evaluate and describe the properties of materials, products, or assemblies in response to
heat and flame under controlled laboratory conditions. It should not be used to describe or appraise the fire hazard or fire risk
of materials, products, or assemblies under actual fire conditions.
1.5.1 The results of this evaluation may be used as elements of a fire-risk assessment that takes into account all of the factors
that are pertinent to an assessment of the fire hazard of a particular end use.
1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.7 The following precautionary caveat pertains only to the test methods portion, Section 7, of this performance specification:
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the
user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations
prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D123 Terminology Relating to Textiles
D434 Test Method for Resistance to Slippage of Yarns in Woven Fabrics Using a Standard Seam
D1424 Test Method for Tearing Strength of Fabrics by Falling-Pendulum (Elmendorf-Type) Apparatus
D2262 Test Method for Tearing Strength of Woven Fabrics by the Tongue (Single Rip) Method (Constant-Rate-of-Traverse
3
Tensile Testing Machine)
D2724 Test Methods for Bonded, Fused, and Laminated Apparel Fabrics
D3786 Test Method for Bursting Strength of Textile FabricsDiaphragm Bursting Strength Tester Method
D5034 Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)
D6413 Test Method for Flame Resistance of Textiles (Vertical Test)
1
This performance specification is under the jurisdiction of ASTM Committee F18 on Electrical Protective Equipment for Workers and is the direct responsibility of
Subcommittee F18.65 on Wearing Apparel.
Current edition approved JuneOct. 1, 2010. Published AugustOctober 2010. Originally approved in 1994. Last previous edition approved in 20082010 as
F1506–08.F1506–10. DOI: 10.1520/F1506-10A.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F1506 – 10a
F1449 Guide for Industrial Lau
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.