Standard Specification for Strength and Protective Coatings on Metal Industrial Chain Link Fence Framework

SCOPE
1.1 This specification covers the strength and protective coating requirements for industrial steel chain link fence framework. Maximum allowable heights of framework and post spacing are to be based on chain link fence fabric mesh size and gages, and specified wind loads. Post spacings are not to exceed 10 ft. (For additional information, see CLFMI Guide WLG2445).
1.1.1 Caution Regarding WindloadIf additives to the fence, such as windscreen, inserts or signage, are required, it is advisable to use stronger framework and fittings, to reduce the on-center spacing of posts or to add back bracing. Factors to consider when determining windload include the type of screening material to be used, area of fence to be covered, and local wind conditions.
1.2 Posts and rails may have any cross-sectional shape meeting the requirements herein. The shapes may be formed and welded, cold formed, hot rolled, or extruded.
1.3 The values in inch-pound units are to be regarded as the standard. The values stated in SI units are for information purposes only.
Note 1—For aluminum-alloy extruded structural pipe and tube please refer to Specification B 429.

General Information

Status
Historical
Publication Date
09-Aug-2003
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1043-03 - Standard Specification for Strength and Protective Coatings on Metal Industrial Chain Link Fence Framework
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F 1043 – 03
Standard Specification for
Strength and Protective Coatings on Steel Industrial Chain
1
Link Fence Framework
This standard is issued under the fixed designation F 1043; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope A 1011 Specification for Steel, Sheet and Strip, Hot-Rolled,
Carbon, Structural, High-Strength Low-Alloy and High-
1.1 This specification covers the strength and protective
3
Strength Low Allow with Improved Formability
coating requirements for industrial steel chain link fence
4
B 6 Specification for Zinc (Slab Zinc)
framework. Maximum allowable heights of framework and
B 308/B 308M Specification for Aluminum Alloy 6061 T6
post spacing are to be based on chain link fence fabric mesh
5
Standard Structural Steel
size and gages, and specified wind loads. Post spacings are not
B 429 Specification for Aluminum-Alloy Extruded Struc-
to exceed 10 ft. (For additional information, see CLFMI Guide
4
tural Pipe and Tube
WLG2445).
B 750 Specification for Zinc-5 % Aluminum-Mischmetal;
1.1.1 Caution Regarding Windload—If additives to the
6
Alloy in Ingot Form for Hot-Dip Coatings
fence, such as windscreen, inserts or signage, are required, it is
D 1499 Practice for Filtered Open-Flame Carbon-Arc Ex-
advisable to use stronger framework and fittings, to reduce the
7
posures of Plastics
on-center spacing of posts or to add back bracing. Factors to
D 3359 Test Methods for Measuring Adhesion by Tape
consider when determining windload include the type of
8
Tests
screening material to be used, area of fence to be covered, and
9
E 8 Test Methods for Tension Testing of Metallic Materials
local wind conditions.
E 376 Practice for Measuring Coating Thickness by
1.2 Posts and rails may have any cross-sectional shape
Magnetic-Field or Eddy-Current (Electromagnetic) Test
meeting the requirements herein. The shapes may be formed
10
Methods
and welded, cold formed, hot rolled, or extruded.
2
F 552 Terminology Relating to Chain Link Fencing
1.3 The values in inch-pound units are to be regarded as the
F 934 Specification for Standard Colors for Polymer Coated
standard. The values stated in SI units are for information
2
Chain Link Fence
purposes only.
F 1083 Specification for Pipe, Steel, Hot-Dipped Zinc
NOTE 1—For aluminum-alloy extruded structural pipe and tube please 2
Coated (Galvanized), Welded, for Fence Structures
refer to Specification B 429.
F 1553 Guide for Specifying Industrial and Commercial
2
Chain Link Fence
2. Referenced Documents
G 23 Practice for Operating Light-Exposure Apparatus
2.1 ASTM Standards:
(Carbon-Arc Type) With and Without Water for Exposure
A 90/A 90M Test Method for Weight [Mass] of Coating on
11
of Nonmetallic Materials
2
Iron or Steel Articles with Zinc or Zinc Alloy Coatings
G 26 Practice for Operating Light-Exposure Apparatus
A 123/A 123M Specification for Zinc (Hot-Dip Galva-
(Xenon-Arc Type) With and Without Water for Exposure
2
nized) Coatings on Iron or Steel Products
12
of Nonmetallic Materials
A 653/A 653M Specification for General Requirements for
Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-
2
Coated (Galvannealed) by the Hot-Dip Process
3
A 875/A 875M Specification for Steel Sheet, Zinc-5 % Annual Book of ASTM Standards, Vol 01.03.
4
2
Annual Book of ASTM Standards, Vol 02.03.
Aluminum Alloy Metallic-Coated by the Hot-Dip Process
5
Annual Book of ASTM Standards, Vol 02.02.
6
Annual Book of ASTM Standards, Vol 02.04.
7
Annual Book of ASTM Standards, Vol 08.01.
8
Annual Book of ASTM Standards, Vol 06.01.
1 9
This specification is under the jurisdiction of ASTM Committee F14 on Fences Annual Book of ASTM Standards, Vol 03.01.
10
and is the direct responsibility of Subcommittee F14.40 on Chain Link Fence and Annual Book of ASTM Standards, Vol 03.03.
11
Wire Accessories. Discontinued. See 1997 Annual Book of ASTM Standards, Vol 14.02. Replaced
Current edition approved August 10, 2003. Published September 2003. Origi- by Practices G 152 and G 153.
12
nally approved in 1995. Last previous edition approved in 2000 as F 1043 – 00. Discontinued. See 1997 Annual Book of ASTM Standards, Vol 14.02. Replaced
2
Annual Book of ASTM Standards, Vol 01.06. by Practice G 155.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F 1043 – 03
TABLE 1 Size Terminology
2.2 CLFMI Guide:
13
WLG2445 Guide for the Selection of Line Post Spacings Trade Size, Designator,
in. [mm] NPS [Metric] Actual Outside Diameter
3. Terminology
in. mm
3
1 ⁄8 [34.9]
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.