ASTM D4459-12
(Practice)Standard Practice for Xenon-Arc Exposure of Plastics Intended for Indoor Applications
Standard Practice for Xenon-Arc Exposure of Plastics Intended for Indoor Applications
SIGNIFICANCE AND USE
4.1 This practice is intended to simulate the effects produced by exposure to solar radiation through glass. This practice uses exposure in a xenon-arc device equipped with window glass filters and operated in accordance with Practices G151 and G155.Note 2—Practice D4674 describes exposures in a device that uses a combination of fluorescent “cool white” and ultraviolet (UV) lamps to simulate the effects of exposures to indoor fluorescent light and window glass filtered daylight.
4.2 Warning—Variation in results may be expected when operating conditions are varied within the accepted limits of this practice. Therefore, all references to the use of this practice must be accompanied by a report prepared in accordance with Section 9 that describes the specific operating conditions used. Refer to Practice G151 for detailed information on the caveats applicable to use of results obtained in accordance with this practice.Note 3—Additional information on sources of variability and on strategies for addressing variability in the design, execution and data analysis of laboratory accelerated exposure tests is found in Guide G141.
4.3 Test results will depend upon the care that is taken to operate the equipment in accordance with Practice G155. Significant factors include regulation of line voltage, temperature and humidity control, and condition and age of the lamps and filters.
4.4 Reproducibility of test results between laboratories has been shown to be good when the stability of materials is evaluated in terms of performance ranking compared to other materials or to a control.4,5 Therefore, exposure of a similar material of known performance (a control) at the same time as the test materials is strongly recommended. It is recommended that at least three replicates of each material be exposed to allow for statistical evaluation of results.
SCOPE
1.1 This practice covers specific procedures and test conditions that are applicable for exposure of plastics in window glass-filtered xenon-arc devices in accordance with Practices G151 and G155 for evaluating the stability of plastics intended for use in indoor applications.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.Note 1—There is no known ISO equivalent to this practice.
General Information
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D4459 − 12
Standard Practice for
Xenon-Arc Exposure of Plastics Intended for Indoor
1
Applications
This standard is issued under the fixed designation D4459; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* of Nonmetallic Materials
G147 Practice for Conditioning and Handling of Nonmetal-
1.1 This practice covers specific procedures and test condi-
lic Materials for Natural and Artificial Weathering Tests
tions that are applicable for exposure of plastics in window
G151 Practice for Exposing Nonmetallic Materials inAccel-
glass-filtered xenon-arc devices in accordance with Practices
erated Test Devices that Use Laboratory Light Sources
G151 and G155 for evaluating the stability of plastics intended
G155 Practice for Operating XenonArc LightApparatus for
for use in indoor applications.
Exposure of Non-Metallic Materials
1.2 This standard does not purport to address all of the
G169 Guide for Application of Basic Statistical Methods to
safety concerns, if any, associated with its use. It is the
Weathering Tests
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
3. Terminology
bility of regulatory limitations prior to use.
3.1 The definitions in Terminology G113 are applicable to
NOTE 1—There is no known ISO equivalent to this practice. this practice.
4. Significance and Use
2. Referenced Documents
2
4.1 This practice is intended to simulate the effects pro-
2.1 ASTM Standards:
duced by exposure to solar radiation through glass. This
D1729 Practice for Visual Appraisal of Colors and Color
practice uses exposure in a xenon-arc device equipped with
Differences of Diffusely-Illuminated Opaque Materials
window glass filters and operated in accordance with Practices
D2244 Practice for Calculation of Color Tolerances and
G151 and G155.
Color Differences from Instrumentally Measured Color
Coordinates
NOTE 2—Practice D4674 describes exposures in a device that uses a
D3980 Practice for Interlaboratory Testing of Paint and
combination of fluorescent “cool white” and ultraviolet (UV) lamps to
3
simulate the effects of exposures to indoor fluorescent light and window
Related Materials (Withdrawn 1998)
glass filtered daylight.
D4674 PracticeforAcceleratedTestingforColorStabilityof
Plastics Exposed to Indoor Office Environments 4.2 Warning—Variation in results may be expected when
D5870 Practice for Calculating Property Retention Index of
operating conditions are varied within the accepted limits of
Plastics thispractice.Therefore,allreferencestotheuseofthispractice
E691 Practice for Conducting an Interlaboratory Study to
must be accompanied by a report prepared in accordance with
Determine the Precision of a Test Method
Section 9 that describes the specific operating conditions used.
G113 Terminology Relating to Natural andArtificial Weath-
Refer to Practice G151 for detailed information on the caveats
ering Tests of Nonmetallic Materials
applicable to use of results obtained in accordance with this
G141 Guide for Addressing Variability in Exposure Testing
practice.
NOTE 3—Additional information on sources of variability and on
strategies for addressing variability in the design, execution and data
1
ThispracticeisunderthejurisdictionofASTMCommitteeD20onPlasticsand
analysis of laboratory accelerated exposure tests is found in Guide G141.
is the direct responsibility of Subcommittee D20.50 on Durability of Plastics.
4.3 Test results will depend upon the care that is taken to
Current edition approved Nov. 15, 2012. Published November 2012. Originally
approved in 1985. Last previous edition approved in 2006 as D4459 - 06. DOI:
operate the equipment in accordance with Practice G155.
10.1520/D4459-12.
Significant factors include regulation of line voltage, tempera-
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
ture and humidity control, and condition and age of the lamps
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on and filters.
the ASTM website.
3
4.4 Reproducibility of test results between laboratories has
The last approved version of this historical standard is referenced on
www.astm.org. been shown to be good when the stability of materials is
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
D4459 − 12
evaluated
...
Designation: D4459 − 06 D4459 − 12
Standard Practice for
Xenon-Arc Exposure of Plastics Intended for Indoor
1
Applications
This standard is issued under the fixed designation D4459; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This practice covers specific procedures and test conditions that are applicable for exposure of plastics in window
glass-filtered xenon-arc devices in accordance with Practices G151 and G155 for evaluating the stability of plastics intended for
use in indoor applications.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
NOTE 1—There is no known ISO equivalent to this practice.
2. Referenced Documents
2
2.1 ASTM Standards:
D1729 Practice for Visual Appraisal of Colors and Color Differences of Diffusely-Illuminated Opaque Materials
D2244 Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates
3
D3980 Practice for Interlaboratory Testing of Paint and Related Materials (Withdrawn 1998)
D4674 Practice for Accelerated Testing for Color Stability of Plastics Exposed to Indoor Office Environments
D5870 Practice for Calculating Property Retention Index of Plastics
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
G113 Terminology Relating to Natural and Artificial Weathering Tests of Nonmetallic Materials
G141 Guide for Addressing Variability in Exposure Testing of Nonmetallic Materials
G147 Practice for Conditioning and Handling of Nonmetallic Materials for Natural and Artificial Weathering Tests
G151 Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light Sources
G155 Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials
G169 Guide for Application of Basic Statistical Methods to Weathering Tests
3. Terminology
3.1 The definitions in Terminology G113 are applicable to this practice.
4. Significance and Use
4.1 This practice is intended to simulate the effects produced by exposure to solar radiation through glass. This practice uses
exposure in a xenon-arc device equipped with window glass filters and operated in accordance with Practices G151 and G155.
NOTE 2—Practice D4674 describes exposures in a device that uses a combination of fluorescent “cool white” and ultraviolet (UV) lamps to simulate
the effects of exposures to indoor fluorescent light and window glass filtered daylight.
4.2 Warning—Variation in results may be expected when operating conditions are varied within the accepted limits of this
practice. Therefore, all references to the use of this practice must be accompanied by a report prepared in accordance with Section
9 that describes the specific operating conditions used. Refer to Practice G151 for detailed information on the caveats applicable
to use of results obtained in accordance with this practice.
NOTE 3—Additional information on sources of variability and on strategies for addressing variability in the design, execution and data analysis of
laboratory accelerated exposure tests is found in Guide G141.
4.3 Test results will depend upon the care that is taken to operate the equipment in accordance with Practice G155. Significant
factors include regulation of line voltage, temperature and humidity control, and condition and age of the burnerlamps and filters.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
D4459 − 12
4.4 Reproducibility of test results between laboratories has been shown to be good when the stability of materials is evaluated
4,5
in terms of performance ranking compared to other materials or to a control. Therefore, exposure of a similar material of known
performance (a control) at the same time as the test materials is strongly recommended. It is recommended that at least three
replicates of each material be exposed to allow for statistical evaluation of results.
5. Apparatus
5.1 Use xenon-arc apparatus that conforms to the requirements defined in Practices G151 and G155.
5.2 The spectral power distribution of the xenon-arc lamp shall conform to the requirements described in Practice G155 for a
xenon-arc lamp with window glass filters.
5.3 Unless otherwise specified, use a xenon-arc device equipped with a radiometer capable of monitoring either narrow-band
or broad-band irradiance incident on test speci
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.