ASTM F1735-09(2015)
(Specification)Standard Specification for Poly (Vinyl Chloride) (PVC) Profile Strip for PVC Liners for Rehabilitation of Existing Man-Entry Sewers and Conduits
Standard Specification for Poly (Vinyl Chloride) (PVC) Profile Strip for PVC Liners for Rehabilitation of Existing Man-Entry Sewers and Conduits
ABSTRACT
This specification covers the requirements and test methods for materials, dimensions, workmanship, extrusion quality, and form of marking for extruded poly(vinyl chloride) (PVC) profile strips used for field fabrication of PVC liners for existing man-entry sewer and conduit rehabilitation. The strips shall be subjected to acetone immersion, elasticity, and hydrostatic pressure tests in the standard laboratory atmosphere under specific temperature and relative humidity conditions to determine conformance to extrusion quality, flexural rigidity, and joint leakage requirements, respectively. The extruded profile strips shall be homogeneous throughout and free from visible cracks, holes, foreign inclusions, or other injurious defects and shall be as uniform as commercially practical in color, opacity, density, and other physical properties.
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, extrusion quality, and a form of marking for extruded poly (vinyl chloride) (PVC) profile strips used for field fabrication of PVC liners for existing man-entry (36 to 144 in. (900 to 3650 mm) in vertical dimension) sewer and conduit rehabilitation.
1.2 Profile strip produced to this specification is for use in field fabrication of PVC liners in non-pressure pipe and conduit rehabilitation where the liner is installed into the existing sewer or conduit and the annular space between the liner and the existing sewer or conduit is grouted with cementitious grout.
Note 1: The practice for the installation of PVC liner covered by this specification is Practice F1698.
1.3 This specification includes extruded profile strips made only from materials specified in 6.1.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F1735 −09 (Reapproved 2015)
Standard Specification for
Poly (Vinyl Chloride) (PVC) Profile Strip for PVC Liners for
Rehabilitation of Existing Man-Entry Sewers and Conduits
This standard is issued under the fixed designation F1735; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* D883 Terminology Relating to Plastics
D1600 Terminology forAbbreviatedTerms Relating to Plas-
1.1 This specification covers requirements and test methods
tics
for materials, dimensions, workmanship, extrusion quality, and
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
a form of marking for extruded poly (vinyl chloride) (PVC)
Compounds and Chlorinated Poly(Vinyl Chloride)
profile strips used for field fabrication of PVC liners for
(CPVC) Compounds
existing man-entry (36 to 144 in. (900 to 3650 mm) in vertical
D2122 Test Method for Determining Dimensions of Ther-
dimension) sewer and conduit rehabilitation.
moplastic Pipe and Fittings
1.2 Profile strip produced to this specification is for use in
D2152 Test Method for Adequacy of Fusion of Extruded
fieldfabricationofPVClinersinnon-pressurepipeandconduit
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
rehabilitationwherethelinerisinstalledintotheexistingsewer
Acetone Immersion
or conduit and the annular space between the liner and the
D2240 Test Method for Rubber Property—Durometer Hard-
existing sewer or conduit is grouted with cementitious grout.
ness
F412 Terminology Relating to Plastic Piping Systems
NOTE 1—The practice for the installation of PVC liner covered by this
specification is Practice F1698.
F1698 Practice for Installation of Poly(Vinyl Chlo-
ride)(PVC) Profile Strip Liner and Cementitious Grout for
1.3 This specification includes extruded profile strips made
Rehabilitation of Existing Man-Entry Sewers and Con-
only from materials specified in 6.1.
duits
1.4 The values stated in inch-pound units are to be regarded
2.2 Federal Standard:
as standard. The values given in parentheses are mathematical
Federal Standard No. 123 Marking For Shipment (Civil
conversions to SI units that are provided for information only 3
Agencies)
and are not considered standard.
2.3 Military Standard:
1.5 This standard does not purport to address all of the
MIL-STD-129 Marking for Shipment and Storage
safety concerns, if any, associated with its use. It is the
3. Terminology
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
3.1 General—Definitions are in accordance with Terminol-
bility of regulatory limitations prior to use.
ogy D883 and Terminology F412. Abbreviations are in accor-
dance with Terminology D1600, unless otherwise indicated.
2. Referenced Documents
3.2 Definitions of Terms Specific to This Standard:
2.1 ASTM Standards:
3.2.1 See Fig. 1 to clarify terminology.
D618 Practice for Conditioning Plastics for Testing
3.2.2 coextruded elastomer seal, n—a elastomer coextruded
D790 Test Methods for Flexural Properties of Unreinforced
in the joiner strip to provide compression sealing of the
and Reinforced Plastics and Electrical Insulating Materi-
mechanical joint made when the joiner strip locks adjacent
als
edges of former strip.
3.2.3 extruded PVC joiner strip, n—a companion product to
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
Piping Systems and is the direct responsibility of Subcommittee F17.67 on the profile former strip of such configuration as to provide the
Trenchless Plastic Pipeline Technology.
locking mechanism at the edges of the former strips.
Current edition approved March 1, 2015. Published April 2015. Originally
3.2.4 extruded PVC profile former strip, n—a product,
approved in 1996. Last previous edition approved in 2009 as F1735 - 09. DOI:
10.1520/F1735-09R15.
available in various sizes, consisting of a smooth inner surface
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,
the ASTM website. Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F1735−09 (2015)
FIG. 1An Example of A Profile PVC Strip
F1735−09 (2015)
NOTE 3—This is intended only for use as a quality control test and not
and a ribbed outer surface (profile) with edge configurations to
for use as a simulated service test.
allow mechanical locking of adjacent strips.
7.2 Flexural (Bending) Properties—The flexural rigidity
3.2.5 production run, n—a continuous extrusion of a given
(stiffness factor) shall be determined in accordance with Test
profile type.
Methods D790, Section on Tangent Modulus of Elasticity,
3.2.6 PVC liner, n—a product field fabricated from extruded
Procedure B, where the equation for E is replaced by EI =
B
PVC profile strip into a shape which substantially conforms to
L m/48 h. Procedure B of Test Methods D790 shall be used in
the shape of the inner surface of the existing pipe or conduit
these tests. This is a qualification test that shall be performed
over some portion or all of its inner circumference.
on each distinct profile product; separate tests shall be per-
formed for each PVC compound used in each distinct profile
4. Significance and Use
product. The test specimens shall be made from a flat sample
4.1 The requirements of this specification are intended to
profile former strip at least 12 in. (300 mm) long, split as near
provide extruded PVC profile suitable for the field fabrication
themiddleofitswidthaspossiblewithoutcuttingthrougharib
of PVC liner for the rehabilitation of existing pipelines and
and the outer edges joined in a joint (approximately in the
conduits conveying sewage, process flow and storm water
center of the width of the specimen and running lengthwise)
under gravity flow conditions.
with the joiner strip installed in the joint. The load shall be
NOTE 2—Industrial waste disposal lines shall be installed only with the applied to the profiled (ribbed) side of the specimens. See Fig.
specific approval of the cognizant code authority since chemicals not
2. The minimum flexural rigidity (stiffness factor) shall be
commonly found in drains and sewers and temperatures in excess of
1600; higher values are available by special order from the
140°F (60°C) may be encountered.
manufacturer of the product. If required by the buyer or
designated in the contract documents or purchase order, or
5. Application of Materials
combination thereof, this test shall be run as a quality control
5.1 The profile strip specified herein can be used for a range
test on each production run supplying materials to the order.
of existing sewer and conduit diameters. The selection of the
7.3 Joint Leakage—A 10 in. (250 mm) sample joint (con-
annulus between the PVC liner and the host structure shall be
sisting of a joiner strip joining two full width panels of former
determined based on analysis of installation conditions.
strip) shall be pressure tested with water at 15 psig (103.5 kPa)
6. Materials and Manufacture
for a maximum 25-h period to simulated ground water leakage
into the lined pipe. The maximum leakage through the joint
6.1 The extruded profile former and joiner strips shall be
shall be 0.00125 gal (4.7 mL) measured over a 1-h period. The
made from PVC compound meeting all the minimum require-
test shall be terminated at the end of any 1-h period during
ments for cell classification 12344 or higher as defined in
which this requirement is satisfied.This test shall be conducted
Specification D1784.
on each production run of extruded PVC joiner strip with
6.2 The elastomer seal shall be made from extrusion grade
samples from the extruded PVC former strip intended for use
elastomer with Shore A durometer of 65 (+5 to –5), when
with that production run of joiner strip. If higher hydrostatic
measured in accordance with Test Method D2240.
testing pressures are required by the buyer, additional testing,
6.3 Rework Material—Clean rework material generated
as agreed between the buyer and seller shall be performed.The
from the manufacturer’s own extruded PVC strip production test fixture used for this test shall provide for the pressurized
may be used by the same manufacturer provided extruded
water to interface with the joint on the ribbed side of the PVC
profile strip produced meets all the requirements of this
panels such that the leakage flow is from the ribbed side to the
specification.
smooth (inner) side of the PVC panels, that is, simulates
ground water into liner. Means shall be provided t
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F1735 − 09 F1735 − 09 (Reapproved 2015)
Standard Specification for
Poly (Vinyl Chloride)(PVC) Chloride) (PVC) Profile Strip for
PVC Liners for Rehabilitation of Existing Man-Entry Sewers
and Conduits
This standard is issued under the fixed designation F1735; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, extrusion quality, and a
form of marking for extruded poly (vinyl chloride)(PVC) chloride) (PVC) profile strips used for field fabrication of PVC liners
for existing man-entry (36 to 144 in. (900 to 3650 mm) in vertical dimension) sewer and conduit rehabilitation.
1.2 Profile strip produced to this specification is for use in field fabrication of PVC liners in non-pressure pipe and conduit
rehabilitation where the liner is installed into the existing sewer or conduit and the annular space between the liner and the existing
sewer or conduit is grouted with cementitious grout.
NOTE 1—The practice for the installation of PVC liner covered by this specification is Practice F1698.
1.3 This specification includes extruded profile strips made only from materials specified in 6.1.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D883 Terminology Relating to Plastics
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone
Immersion
D2240 Test Method for Rubber Property—Durometer Hardness
F412 Terminology Relating to Plastic Piping Systems
F1698 Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner and Cementitious Grout for Rehabilitation of
Existing Man-Entry Sewers and Conduits
2.2 Federal Standard:
Federal Standard No. 123 Marking For Shipment (Civil Agencies)
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.67 on Trenchless
Plastic Pipeline Technology.
Current edition approved Dec. 1, 2009March 1, 2015. Published December 2009April 2015. Originally approved in 1996. Last previous edition approved in 20082009
as F1735 - 02F1735 - 09.(2008). DOI: 10.1520/F1735-09.10.1520/F1735-09R15.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, DLA Document Services, Building 4/D, 700 Robbins Ave., Philadelphia, PA
19111-5098, http://www.dodssp.daps.mil. 19111-5094, http://quicksearch.dla.mil.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F1735 − 09 (2015)
2.3 Military Standard:
MIL-STD-129 Marking for Shipment and Storage
3. Terminology
3.1 General—Definitions are in accordance with Terminology D883 and Terminology F412. Abbreviations are in accordance
with Terminology D1600, unless otherwise indicated.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 See Fig. 1 to clarify terminology.
3.2.2 coextruded elastomer seal, n—a elastomer coextruded in the joiner strip to provide compression sealing of the mechanical
joint made when the joiner strip locks adjacent edges of former strip.
3.2.3 extruded PVC joiner strip, n—a companion product to the profile former strip of such configuration as to provide the
locking mechanism at the edges of the former strips.
3.2.4 extruded PVC profile former strip, n—a product, available in various sizes, consisting of a smooth inner surface and a
ribbed outer surface (profile) with edge configurations to allow mechanical locking of adjacent strips.
3.2.5 production run, n—a continuous extrusion of a given profile type.
3.2.6 PVC liner, n—a product field fabricated from extruded PVC profile strip into a shape which substantially conforms to the
shape of the inner surface of the existing pipe or conduit over some portion or all of its inner circumference.
4. Significance and Use
4.1 The requirements of this specification are intended to provide extruded PVC profile suitable for the field fabrication of PVC
liner for the rehabilitation of existing pipelines and conduits conveying sewage, process flow and storm water under gravity flow
conditions.
NOTE 2—Industrial waste disposal lines shall be installed only with the specific approval of the cognizant code authority since chemicals not commonly
found in drains and sewers and temperatures in excess of 140°F (60°C) may be encountered.
5. Application of Materials
5.1 The profile strip specified herein can be used for a range of existing sewer and conduit diameters. The selection of the
annulus between the PVC liner and the host structure shall be determined based on analysis of installation conditions.
6. Materials and Manufacture
6.1 The extruded profile former and joiner strips shall be made from PVC compound meeting all the minimum requirements
for cell classification 12344 or higher as defined in Specification D1784.
6.2 The elastomer seal shall be made from extrusion grade elastomer with Shore A durometer of 65 (+5 to –5), when measured
in accordance with Test Method D2240.
6.3 Rework Material—Clean rework material generated from the manufacturer’s own extruded PVC strip production may be
used by the same manufacturer provided extruded profile strip produced meets all the requirements of this specification.
7. Other Requirements
7.1 Acetone Immersion—The profile strip shall not flake or disintegrate when tested in accordance with 11.3.
NOTE 3—This is intended only for use as a quality control test and not for use as a simulated service test.
7.2 Flexural (Bending) Properties—The flexural rigidity (stiffness factor) shall be determined in accordance with Test
MethodMethods D790, Section on Tangent Modulus of Elasticity, Procedure B, where the equation for E is replaced by EI =
B
L m/48 h. Procedure B of Test Method 790Methods D790 shall be used in these tests. This is a qualification test that shall be
performed on each distinct profile product; separate tests shall be performed for each PVC compound used in each distinct profile
product. The test specimens shall be made from a flat sample profile former strip at least 12 in. ( mm) (300 mm) long, split as near
the middle of its width as possible without cutting through a rib and the outer edges joined in a joint (approximately in the center
of the width of the specimen and running lengthwise) with the joiner strip installed in the joint. The load shall be applied to the
profiled (ribbed) side of the specimens. See Fig. 2. The minimum flexural rigidity (stiffness factor) shall be 1600; higher values
are available by special order from the manufacturer of the product. If required by the buyer or designated in the contract
documents or purchase order, or combination thereof, this test shall be run as a quality control test on each production run
supplying materials to the order.
7.3 Joint Leakage—A10A 10 in. (250 mm) sample joint (consisting of a joiner strip joining two full width panels of former strip)
shall be pressure tested with water at 15 psig (103.5 kPa) for a maximum 25 h 25-h period to simulated ground water leakage into
the lined pipe. The maximum leakage through the joint shall be 0.00125 gal (4.7 mL) measured over a one hour 1-h period. The
test shall be terminated at the end of any one hour 1-h period during which this requirement is satisfied. This test shall be conducted
F1735 − 09 (2015)
FIG. 1 An Example of A Profile PVC Strip
F1735 − 09 (2015)
FIG. 2 Stiffness Factor (EI) Test Specimen
on each production run of extruded PVC joiner strip with samples from the extruded PVC former strip intended for use with that
production run of joiner strip
...