Standard Specification for Poly (Vinyl Chloride) (PVC) Profile Strip for PVC Liners for Rehabilitation of Existing Man-Entry Sewers and Conduits

ABSTRACT
This specification covers the requirements and test methods for materials, dimensions, workmanship, extrusion quality, and form of marking for extruded poly(vinyl chloride) (PVC) profile strips used for field fabrication of PVC liners for existing man-entry sewer and conduit rehabilitation. The strips shall be subjected to acetone immersion, elasticity, and hydrostatic pressure tests in the standard laboratory atmosphere under specific temperature and relative humidity conditions to determine conformance to extrusion quality, flexural rigidity, and joint leakage requirements, respectively. The extruded profile strips shall be homogeneous throughout and free from visible cracks, holes, foreign inclusions, or other injurious defects and shall be as uniform as commercially practical in color, opacity, density, and other physical properties.
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, extrusion quality, and a form of marking for extruded poly (vinyl chloride) (PVC) profile strips used for field fabrication of PVC liners for existing man-entry (36 in. to 144 in. (900 mm to 3650 mm) in vertical dimension) sewer and conduit rehabilitation.  
1.2 Profile strip produced to this specification is for use in field fabrication of PVC liners in non-pressure pipe and conduit rehabilitation where the liner is installed into the existing sewer or conduit and the annular space between the liner and the existing sewer or conduit is grouted with cementitious grout.
Note 1: The practice for the installation of PVC liner covered by this specification is Practice F1698.  
1.3 This specification includes extruded profile strips made only from materials specified in 6.1.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
14-Feb-2021
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1735-21 - Standard Specification for Poly (Vinyl Chloride) (PVC) Profile Strip for PVC Liners for Rehabilitation of Existing Man-Entry Sewers and Conduits
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F1735-21 - Standard Specification for Poly (Vinyl Chloride) (PVC) Profile Strip for PVC Liners for Rehabilitation of Existing Man-Entry Sewers and Conduits
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:F1735 −21
Standard Specification for
Poly (Vinyl Chloride) (PVC) Profile Strip for PVC Liners for
1
Rehabilitation of Existing Man-Entry Sewers and Conduits
This standard is issued under the fixed designation F1735; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 2. Referenced Documents
2
1.1 This specification covers requirements and test methods 2.1 ASTM Standards:
formaterials,dimensions,workmanship,extrusionquality,and D618Practice for Conditioning Plastics for Testing
a form of marking for extruded poly (vinyl chloride) (PVC) D790Test Methods for Flexural Properties of Unreinforced
profile strips used for field fabrication of PVC liners for and Reinforced Plastics and Electrical Insulating Materi-
existing man-entry (36 in. to 144 in. (900 mm to 3650 mm) in als
vertical dimension) sewer and conduit rehabilitation. D883Terminology Relating to Plastics
D1600TerminologyforAbbreviatedTermsRelatingtoPlas-
1.2 Profile strip produced to this specification is for use in
tics
fieldfabricationofPVClinersinnon-pressurepipeandconduit
D1784Classification System and Basis for Specification for
rehabilitationwherethelinerisinstalledintotheexistingsewer
Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlo-
or conduit and the annular space between the liner and the
rinated Poly(Vinyl Chloride) (CPVC) Compounds
existing sewer or conduit is grouted with cementitious grout.
D2122Test Method for Determining Dimensions of Ther-
NOTE 1—The practice for the installation of PVC liner covered by this
moplastic Pipe and Fittings
specification is Practice F1698.
D2152Test Method for Adequacy of Fusion of Extruded
1.3 This specification includes extruded profile strips made
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
only from materials specified in 6.1.
Acetone Immersion
D2240TestMethodforRubberProperty—DurometerHard-
1.4 Thevaluesstatedininch-poundunitsaretoberegarded
ness
as standard. The values given in parentheses are mathematical
D4226Test Methods for Impact Resistance of Rigid Poly-
conversions to SI units that are provided for information only
(Vinyl Chloride) (PVC) Building Products
and are not considered standard.
F412Terminology Relating to Plastic Piping Systems
1.5 This standard does not purport to address all of the
F1057Practice for Estimating the Quality of Extruded Poly
safety concerns, if any, associated with its use. It is the
(Vinyl Chloride) (PVC) Pipe by the Heat Reversion
responsibility of the user of this standard to establish appro-
Technique
priate safety, health, and environmental practices and deter-
F1698 Practice for Installation of Poly(Vinyl Chlo-
mine the applicability of regulatory limitations prior to use.
ride)(PVC)ProfileStripLinerandCementitiousGroutfor
1.6 This international standard was developed in accor-
Rehabilitation of Existing Man-Entry Sewers and Con-
dance with internationally recognized principles on standard-
duits
ization established in the Decision on Principles for the
2.2 Federal Standard:
Development of International Standards, Guides and Recom-
Federal Standard No. 123Marking For Shipment (Civil
mendations issued by the World Trade Organization Technical
3
Agencies)
Barriers to Trade (TBT) Committee.
1 2
This specification is under the jurisdiction ofASTM Committee F17 on Plastic For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Piping Systems and is the direct responsibility of Subcommittee F17.67 on contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Trenchless Plastic Pipeline Technology. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Feb. 15, 2021. Published March 2021. Originally the ASTM website.
3
approved in 1996. Last previous edition approved in 2015 as F1735-09(2015). Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,
DOI: 10.1520/F1735-21. Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1735−21
2.3 Military Standard: conduits conveying sewage, process flow and storm water
3
MIL-STD-129Marking for Shipment and Storage under gravity flow conditions.
NOTE 2—Industrial waste disposal lines shall be installed only with the
3. Ter
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F1735 − 09 (Reapproved 2015) F1735 − 21
Standard Specification for
Poly (Vinyl Chloride) (PVC) Profile Strip for PVC Liners for
1
Rehabilitation of Existing Man-Entry Sewers and Conduits
This standard is issued under the fixed designation F1735; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, extrusion quality, and a form
of marking for extruded poly (vinyl chloride) (PVC) profile strips used for field fabrication of PVC liners for existing man-entry
(36 in. to 144 in. (900 mm to 3650 mm) in vertical dimension) sewer and conduit rehabilitation.
1.2 Profile strip produced to this specification is for use in field fabrication of PVC liners in non-pressure pipe and conduit
rehabilitation where the liner is installed into the existing sewer or conduit and the annular space between the liner and the existing
sewer or conduit is grouted with cementitious grout.
NOTE 1—The practice for the installation of PVC liner covered by this specification is Practice F1698.
1.3 This specification includes extruded profile strips made only from materials specified in 6.1.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D883 Terminology Relating to Plastics
D1600 Terminology for Abbreviated Terms Relating to Plastics
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.67 on Trenchless
Plastic Pipeline Technology.
Current edition approved March 1, 2015Feb. 15, 2021. Published April 2015March 2021. Originally approved in 1996. Last previous edition approved in 20092015 as
F1735 - 09.F1735 - 09(2015). DOI: 10.1520/F1735-09R15.10.1520/F1735-21.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1735 − 21
D1784 Classification System and Basis for Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated
Poly(Vinyl Chloride) (CPVC) Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone
Immersion
D2240 Test Method for Rubber Property—Durometer Hardness
D4226 Test Methods for Impact Resistance of Rigid Poly(Vinyl Chloride) (PVC) Building Products
F412 Terminology Relating to Plastic Piping Systems
F1057 Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique
F1698 Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner and Cementitious Grout for Rehabilitation of
Existing Man-Entry Sewers and Conduits
2.2 Federal Standard:
3
Federal Standard No. 123 Marking For Shipment (Civil Agencies)
2.3 Military Standard:
3
MIL-STD-129 Marking for Shipment and Storage
3. Terminology
3.1 Gen
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.