Standard Specification for Nonvulcanized (Uncured) Rubber Sheet Used as Roof Flashing

ABSTRACT
This specification covers nonvulcanized (uncured) rubber sheet made of ethylene-propylene-diene terpolymer (EPDM) or polychloroprene (CR) intended for use as watertight roof flashing exposed to the weather. In-place roof system design criteria such as fire resistance, field seaming strength, material compatibility, and uplift resistance, among others, are beyond the scope of this specification. The flashing material shall be formulated from the appropriate polymer type and other compounding ingredients, and shall be capable of being bonded to itself, to the roofing membrane, and to substrate for making watertight field splices and repairs. Property requirements for flashing before vulcanization include thickness, Green strength modulus, ultimate elongation, shelf stability, vulcanizability, tensile strength and set, dimensional stability, and weatherability. Consequently, the property requirements for flashing after vulcanization includes tensile strength and set, elongation, tear resistance, brittle point, ozone resistance, air oven heat aging, water absorption and weight change, linear dimension change, and weatherability.
SCOPE
1.1 This specification covers nonvulcanized (uncured) rubber sheet made of EPDM (ethylene-propylene-diene terpolymer) or CR (polychloroprene) intended for use as watertight roof flashing exposed to the weather.  
1.2 The tests and property limits used to characterize these flashing materials are specific for each classification and are minimum values to make the product fit for its intended purpose.  
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.  
1.4 In-place roof system design criteria, such as fire resistance, field seaming strength, material compatibility, and uplift resistance, among others, are beyond the scope of this specification.  
1.5 The following precautionary caveat pertains to the test methods portion only, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Dec-2022
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D4811/D4811M-16(2023) - Standard Specification for Nonvulcanized (Uncured) Rubber Sheet Used as Roof Flashing
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:D4811/D4811M −16 (Reapproved 2023)
Standard Specification for
Nonvulcanized (Uncured) Rubber Sheet Used as Roof
1
Flashing
This standard is issued under the fixed designation D4811/D4811M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This specification covers nonvulcanized (uncured) rub-
D412TestMethodsforVulcanizedRubberandThermoplas-
ber sheet made of EPDM (ethylene-propylene-diene terpoly-
tic Elastomers—Tension
mer) or CR (polychloroprene) intended for use as watertight
D471Test Method for Rubber Property—Effect of Liquids
roof flashing exposed to the weather.
D518 Test Method for Rubber Deterioration—Surface
3
1.2 The tests and property limits used to characterize these
Cracking (Withdrawn 2007)
flashing materials are specific for each classification and are
D573Test Method for Rubber—Deterioration in an Air
minimum values to make the product fit for its intended
Oven
purpose. D624Test Method for Tear Strength of Conventional Vul-
canized Rubber and Thermoplastic Elastomers
1.3 The values stated in either SI units or inch-pound units
D1079Terminology Relating to Roofing and Waterproofing
are to be regarded separately as standard. The values stated in
D1149TestMethodsforRubberDeterioration—Crackingin
each system may not be exact equivalents; therefore, each
an Ozone Controlled Environment
system shall be used independently of the other. Combining
D1204Test Method for Linear Dimensional Changes of
values from the two systems may result in nonconformance
Nonrigid Thermoplastic Sheeting or Film at Elevated
with the standard.
Temperature
D1418 Practice for Rubber and Rubber Latices—
1.4 In-place roof system design criteria, such as fire
Nomenclature
resistance, field seaming strength, material compatibility, and
D2137TestMethodsforRubberProperty—BrittlenessPoint
uplift resistance, among others, are beyond the scope of this
of Flexible Polymers and Coated Fabrics
specification.
D3182PracticeforRubber—Materials,Equipment,andPro-
1.5 The following precautionary caveat pertains to the test
cedures for Mixing Standard Compounds and Preparing
methods portion only, Section 8, of this specification: This
Standard Vulcanized Sheets
standarddoesnotpurporttoaddressallofthesafetyconcerns,
G151PracticeforExposingNonmetallicMaterialsinAccel-
ifany,associatedwithitsuse.Itistheresponsibilityoftheuser
erated Test Devices that Use Laboratory Light Sources
of this standard to establish appropriate safety, health, and
G154Practice for Operating Fluorescent Ultraviolet (UV)
environmental practices and determine the applicability of
Lamp Apparatus for Exposure of Nonmetallic Materials
regulatory limitations prior to use. G155PracticeforOperatingXenonArcLampApparatusfor
Exposure of Materials
1.6 This international standard was developed in accor-
dance with internationally recognized principles on standard-
3. Classification
ization established in the Decision on Principles for the
3.1 The following types are used to identify the principal
Development of International Standards, Guides and Recom-
polymer components of the flashing material (see Note 1):
mendations issued by the World Trade Organization Technical
3.1.1 Type I—Ethylene-Propylene-Diene Terpolymer
Barriers to Trade (TBT) Committee.
(EPDM).
1 2
This specification is under the jurisdiction of ASTM Committee D08 on For referenced ASTM standards, visit the ASTM website, www.astm.org, or
RoofingandWaterproofingandisthedirectresponsibilityofSubcommitteeD08.18 contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
on Nonbituminous Organic Roof Coverings. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Jan. 1, 2023. Published January 2023. Originally the ASTM website.
3
approved in 1990. Last previous edition approved in 2016 as D4811/D4811M–16. The last approved version of this historical standard is referenced on
DOI: 10.1520/D4811_D4811M-16R23. www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D4811/D4811M−16 (2023)
TABLE 2 Property Requirements for Flashing After Vulcanization
3.1.2 Type II—Chloroprene Polymer (CR).
Type I, Type II,
NOTE 1—For definitions of polymer types, see Practice D1418. For
Class V Class V
definitions of terms related to
...

Questions, Comments and Discussion