ASTM A377-03(2008)e1
(Specification)Standard Index of Specifications for Ductile-Iron Pressure Pipe
Standard Index of Specifications for Ductile-Iron Pressure Pipe
SCOPE
1.1 This index identifies specifications that cover ductile-iron pressure pipe suitable for carrying water and other liquids under pressure.
Note 1—The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation: A377 −03(Reapproved 2008)
Standard Index of Specifications for
Ductile-Iron Pressure Pipe
This standard is issued under the fixed designation A377; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
´ NOTE—ANSI/AWWA C110/A21.10 reference editorially corrected on Oct. 1, 2008.
1. Scope ANSI/AWWA C104/A21.4, Cement-Mortar Lining for
2,3
Ductile-Iron Pipe and Fittings for Water,
1.1 This index identifies specifications that cover ductile-
ANSI/AWWA C105/A21.5, Polyethylene Encasement for
iron pressure pipe suitable for carrying water and other liquids
2,3
Ductile-Iron Pipe Systems,
under pressure.
ANSI/AWWA C106/A21.50, Thickness Design of Ductile-
2,3
NOTE 1—The text of this standard references notes and footnotes which
Iron Pipe,
provide explanatory material. These notes and footnotes (excluding those
ANSI/AWWA C110/A21.10, Ductile-Iron and Gray-Iron
in tables and figures) shall not be considered as requirements of the
2,3
Fittings for Water,
standard.
ANSI/AWWA C111/A21.11, Rubber–Gasket Joints for
2,3
2. Method of Designation
Ductile-Iron Pressure Pipe and Fittings,
ANSI/AWWAC115/A21.15, Flanged Ductile-Iron Pipe with
2.1 The ASTM designation for these specifications is not
2,3
Ductile-Iron or Gray-Iron Threaded Flanges,
sufficient to describe the particular items which a purchaser
ANSI/AWWA C116/A21.16, Protective Fusion-Bonded Ep-
may desire; therefore, the ANSI designation for the applicable
oxy Coatings for the Interior and Exterior Surfaces of Ductile-
American National Standards shown in Section 3 shall be
2,3
Iron and Gray-Iron Fittings for Water Supply Service,
specified in the inquiry, contract, and order.
ANSI/AWWA C153/A21.53, Ductile Iron Compact Fittings
2,3
3. Reference Specifications
for Water Service,
ANSI/AWWA C600, Installation of Ductile-Iron Water
3.1 Ductile iron pipe furnished in accordance with this
2,3
Mains and Their Appurtenances, and
index are covered by the following American National Stan-
2,3
ANSI/AWWA C606, Grooved and Shouldered Joints,
dards:
ANSI/AWWA C151/A21.51, Ductile-Iron Pipe, Centrifu-
NOTE 2—These specifications were prepared by appropriate subcom-
2,3
gally Cast for Water,
mittees ofAmerican Water WorksAssociation CommitteeA21 on Ductile
Iron Pipe and Fittings. This committee was originally organized as an
3.2 Other American National Standards relating to ductile-
AmericanNationalStandardsCommitteeunderthesponsorshipofASTM,
iron pipe are the following:
American Gas Association (A.G.A), American Water Works Association
(AWWA), and New Engl
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation:A 377–03 Designation: A 377 – 03 (Reapproved 2008)
Standard Index of Specifications for
Ductile-Iron Pressure Pipe
This standard is issued under the fixed designation A 377; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
´ NOTE—ANSI/AWWA C110/A21.10 reference editorially corrected on Oct. 1, 2008.
1. Scope
1.1 This index identifies specifications that cover ductile-iron pressure pipe suitable for carrying water and other liquids under
pressure.
NOTE 1—The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in
tables and figures) shall not be considered as requirements of the standard.
2. Method of Designation
2.1 The ASTM designation for these specifications is not sufficient to describe the particular items which a purchaser may
desire; therefore, the ANSI designation for the applicable American National Standards shown in Section 3 shall be specified in
the inquiry, contract, and order.
3. Reference Specifications
3.1 Ductile iron pipe furnished in accordance with this index are covered by the following American National Standards:
,
2 3
ANSI/AWWA C151/A21.51, Ductile-Iron Pipe, Centrifugally Cast for Water,
3.2 Other American National Standards relating to ductile-iron pipe are the following:
2,3
ANSI/AWWA C104/A21.4, Cement-Mortar Lining for Ductile-Iron Pipe and Fittings for Water,
,
2 3
ANSI/AWWA C105/A21.5, Polyethylene Encasement for Ductile-Iron Pipe Systems,
2,3
ANSI/AWWA C106/A21.50, Thickness Design of Ductile-Iron Pipe,
ANSI/AWWA C110/A21.10, Ductile-Iron and Gray-Iron Fittings, 3 in. through 48 in. (76 mm through 1219 mm) for Water,
,
ANSI/AWWA C110/A21.10, Ductile-Iron and Gray-Iron Fittings for Water,
,
2 3
ANSI/AWWA C111/A21.11, Rubber–Gasket Joints for Ductile-Iron Pressure Pipe and Fittings,
2,3
ANSI/AWWA C115/A21.15, Flanged Ductile-Iron Pipe with Ductile-Iron or Gray-Iron Threaded Flanges,
ANSI/AWWA C116/A21.16, Protective Fusion-Bonded Epoxy Coatings for the Interior and Exterior Surfaces of Ductile-Iron
2,3
and Gray-Iron Fittings for Water Supply Service,
,
2 3
ANSI/AWWA C153/A21.53, Ductile Iron Compact Fittings for Water Service,
2,3
ANSI/AWWA C600, Installation of Ductile-Iron Water Mains and Their Appurtenances, and
,
2 3
ANSI/AWWA C606, Grooved and Shouldered Joints,
NOTE 2—Thesespecificationswerepreparedbyap
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.