Standard Test Method for Covering Capacity and Volume Change Upon Drying of Thermal Insulating Cement

SIGNIFICANCE AND USE
4.1 This test method is used to determine the wet covering and volume change upon drying of thermal insulating cement.
SCOPE
1.1 Wet covering capacity and volume change upon drying are often of major importance in the application of thermal insulating cement. These properties can be easily determined at the same time that the determinations of dry covering capacity are made. Therefore, the procedures for determining these three properties are covered together in this test method.  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Aug-2016
Current Stage
Ref Project

Buy Standard

Standard
ASTM C166-05(2016) - Standard Test Method for Covering Capacity and Volume Change Upon Drying of Thermal Insulating Cement
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM C166-05(2016) - Standard Test Method for Covering Capacity and Volume Change Upon Drying of Thermal Insulating Cement
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C166 − 05 (Reapproved 2016)
Standard Test Method for
Covering Capacity and Volume Change Upon Drying of
1
Thermal Insulating Cement
This standard is issued under the fixed designation C166; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope cement is mixed with the recommended amount of water,
molded, and dried to constant weight in accordance with
1.1 Wet covering capacity and volume change upon drying
Section 6.
are often of major importance in the application of thermal
2
insulating cement. These properties can be easily determined at 3.3 wet covering capacity—the area covered in “ft , 1 in. in
2
the same time that the determinations of dry covering capacity
thickness/100 lb of dry cement” (m , 1 cm in thickness/100 kg
are made. Therefore, the procedures for determining these of dry cement) when the cement is mixed with the recom-
three properties are covered together in this test method.
mended amount of water and molded in accordance with
Section 6.
1.2 The values stated in inch-pound units are to be regarded
as standard. The values given in parentheses are mathematical
3.4 Definitions in Terminology C168 shall be considered as
conversions to SI units that are provided for information only
applying to the terms used in this test method.
and are not considered standard.
4. Significance and Use
1.3 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
4.1 This test method is used to determine the wet covering
responsibility of the user of this standard to establish appro-
and volume change upon drying of thermal insulating cement.
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
5. Apparatus
5.1 Mold—A rigid mold having inside dimensions of 1 by 8
2. Referenced Documents
by 30 in. (25.4 by 203 by 726 mm) with one end and one face
2
2.1 ASTM Standards:
1
open, and a piece of wood or other suitable material 1 by 1 ⁄2
C163 Practice for Mixing Thermal Insulating Cement
7
by 7 ⁄8 in. (25.4 by 38.1 by 200 mm) in dimensions for squaring
Samples
up the end of the test specimen toward the open end of the
C168 Terminology Relating to Thermal Insulation
mold.
5.2 Wax Paper—Sheets of wax paper 8 by 30 in. (200 by
3. Terminology
762 mm) in dimensions.
2
3.1 dry covering capacity—the area covered in “ft , 1 in. in
2
5.3 Engine Oil.
thickness/100 lb of dry cement” (m , 1 cm in thickness/100 kg
of dry cement) after the wet cement has been molded and dried
5.4 Trowel—A 16-in. (about 400-mm) rectangular plaster-
to constant weight in accordance with Section 6.
er’s trowel.
3.2 volume change upon drying—the percentage change in
1
5.5 Steel Rules—Steel rules 18 and 36 in. (about ⁄2 and 1 m)
volume of the wet molded cement that occurs when the dry
1
in length accurate to within ⁄64 in. (0.5 mm).
5.6 Depth Gage—A depth gage consisting of a rigid,
1
pointed rod approximately ⁄8 in. (3 mm) in diameter, fitted
1
This test method is under the jurisdiction of ASTM Committee C16 on Thermal
1
with a flat disk about ⁄2 in. (13 mm) in diameter which is
Insulation and is the direct responsibility of Subcommittee C16.31 on Chemical and
moved along the rod either by a sliding action or by means of
Physical Properties.
Current edition approved Sept. 1, 2016. Published September 2016. Originally
threads.
approved in 1941. Last previous edition approved in 2010 as C166 – 05 (2010).
DOI: 10.1520/C0166-05R16.
2
6. Sampling and Mixing
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
6.1 The cement shall be sampled and mixed in accordance
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. with Practice C163.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C166 − 05 (2016)
7. Procedure complete circulation of the atmosphere of the entire oven
chamber, preferably by fan or other forced circulation method.
7.1 Oil the inside surfaces of the mold well, or line them
with wax paper in order to prevent the cement from sticking to 7.7 After the dried specimen has been weighed, measure it
the sides and to permit convenient removal of the specimen.
for thickness, width, and length at the same locations at which
Then place the mixed cement in the mold. corresponding measurements were made before the specimen
was dried. These locations are indi
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C166 − 05 (Reapproved 2010) C166 − 05 (Reapproved 2016)
Standard Test Method for
Covering Capacity and Volume Change Upon Drying of
1
Thermal Insulating Cement
This standard is issued under the fixed designation C166; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 Wet covering capacity and volume change upon drying are often of major importance in the application of thermal insulating
cement. These properties can be easily determined at the same time that the determinations of dry covering capacity are made.
Therefore, the procedures for determining these three properties are covered together in this test method.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information
only.mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C163 Practice for Mixing Thermal Insulating Cement Samples
C168 Terminology Relating to Thermal Insulation
3. Terminology
2 2
3.1 dry covering capacity—the area covered in “ft , 1 in. in thickness/100 lb of dry cement” (m , 1 cm in thickness/100 kg of
dry cement) after the wet cement has been molded and dried to constant weight in accordance with Section 6.
3.2 volume change upon drying—the percentage change in volume of the wet molded cement that occurs when the dry cement
is mixed with the recommended amount of water, molded, and dried to constant weight in accordance with Section 6.
2 2
3.3 wet covering capacity—the area covered in “ft , 1 in. in thickness/100 lb of dry cement” (m , 1 cm in thickness/100 kg of
dry cement) when the cement is mixed with the recommended amount of water and molded in accordance with Section 6.
3.4 Definitions in Terminology C168 shall be considered as applying to the terms used in this test method.
4. Significance and Use
4.1 This test method is used to determine the wet covering and volume change upon drying of thermal insulating cement.
5. Apparatus
5.1 Mold—A rigid mold having inside dimensions of 1 by 8 by 30 in. (25.4 by 203 by 726 mm) with one end and one face open,
1 7
and a piece of wood or other suitable material 1 by 1 ⁄2 by 7 ⁄8 in. (25.4 by 38.1 by 200 mm) in dimensions for squaring up the
end of the test specimen toward the open end of the mold.
5.2 Wax Paper—Sheets of wax paper 8 by 30 in. (200 by 762 mm) in dimensions.
1
This test method is under the jurisdiction of ASTM Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.31 on Chemical and
Physical Properties.
Current edition approved Sept. 1, 2010Sept. 1, 2016. Published November 2010September 2016. Originally approved in 1941. Last previous edition approved in 20052010
as C166 – 05.C166 – 05 (2010). DOI: 10.1520/C0166-05R10.10.1520/C0166-05R16.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C166 − 05 (2016)
5.3 Engine Oil.
5.4 Trowel—A 16-in. (about 400-mm) rectangular plasterer’s trowel.
1 1
5.5 Steel Rules—Steel rules 18 and 36 in. (about ⁄2 and 1 m) in length accurate to within ⁄64 in. (0.5 mm).
1
5.6 Depth Gage—A depth gage consisting of a rigid, pointed rod approximately ⁄8 in. (3 mm) in diameter, fitted with a flat disk
1
about ⁄2 in. (13 mm) in diameter which is moved along the rod either by a sliding action or by means of threads.
6. Sampling and Mixing
6.1 The cement shall be sampled and mixed in acco
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.