Standard Practice for Presentation of Constant Amplitude Fatigue Test Results for Metallic Materials

SIGNIFICANCE AND USE
4.1 Fatigue test results may be significantly influenced by the properties and history of the parent material, the operations performed during the preparation of the fatigue specimens, and the testing machine and test procedures used during the generation of the data. The presentation of fatigue test results should include citation of basic information on the material, specimens, and testing to increase the utility of the results and to reduce to a minimum the possibility of misinterpretation or improper application of those results.
SCOPE
1.1 This practice covers the desirable and minimum information to be communicated between the originator and the user of data derived from constant-force amplitude axial, bending, or torsion fatigue tests of metallic materials tested in air and at room temperature.  
Note 1: Practice E466, although not directly referenced in the text, is considered important enough to be listed in this standard.  
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Oct-2023
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E468/E468M-23a - Standard Practice for Presentation of Constant Amplitude Fatigue Test Results for Metallic Materials
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM E468/E468M-23a - Standard Practice for Presentation of Constant Amplitude Fatigue Test Results for Metallic Materials
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E468/E468M − 23a
Standard Practice for
Presentation of Constant Amplitude Fatigue Test Results for
1
Metallic Materials
This standard is issued under the fixed designation E468/E468M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope E466 Practice for Conducting Force Controlled Constant
Amplitude Axial Fatigue Tests of Metallic Materials
1.1 This practice covers the desirable and minimum infor-
E467 Practice for Verification of Constant Amplitude Dy-
mation to be communicated between the originator and the user
namic Forces in an Axial Fatigue Testing System
of data derived from constant-force amplitude axial, bending,
E739 Guide for Statistical Analysis of Linear or Linearized
or torsion fatigue tests of metallic materials tested in air and at
Stress-Life (S-N) and Strain-Life (ε-N) Fatigue Data
room temperature.
3
(Withdrawn 2024)
NOTE 1—Practice E466, although not directly referenced in the text, is
E1823 Terminology Relating to Fatigue and Fracture Testing
considered important enough to be listed in this standard.
2.2 Special Technical Publications:
1.2 The values stated in either SI units or inch-pound units
STP 91–A A Guide for Fatigue Testing and the Statistical
4
are to be regarded separately as standard. The values stated in
Analysis of Fatigue Data
5
each system are not necessarily exact equivalents; therefore, to
STP 588 Manual on Statistical Planning and Analysis
ensure conformance with the standard, each system shall be
3. Terminology Definitions and Nomenclature
used independently of the other, and values from the two
systems shall not be combined.
3.1 The terms and abbreviations used in this practice are
1.3 This standard does not purport to address all of the defined in Terminology E6 and in Terminology E1823.
safety concerns, if any, associated with its use. It is the
4. Significance and Use
responsibility of the user of this standard to establish appro-
priate safety, health, and environmental practices and deter-
4.1 Fatigue test results may be significantly influenced by
mine the applicability of regulatory limitations prior to use.
the properties and history of the parent material, the operations
1.4 This international standard was developed in accor-
performed during the preparation of the fatigue specimens, and
dance with internationally recognized principles on standard-
the testing machine and test procedures used during the
ization established in the Decision on Principles for the
generation of the data. The presentation of fatigue test results
Development of International Standards, Guides and Recom-
should include citation of basic information on the material,
mendations issued by the World Trade Organization Technical
specimens, and testing to increase the utility of the results and
Barriers to Trade (TBT) Committee.
to reduce to a minimum the possibility of misinterpretation or
improper application of those results.
2. Referenced Documents
5. Listing of Basic Information About Fatigue Test
2
2.1 ASTM Standards:
Specimen
E6 Terminology Relating to Methods of Mechanical Testing
5.1 Specification and Properties of Material:
E8/E8M Test Methods for Tension Testing of Metallic Ma-
5.1.1 Material Prior to Fatigue Test Specimen
terials
Preparation—The minimum information to be presented
should include the designation or specification (for example,
A441, SAE 1070, and so forth) or proprietary grade; form of
1
This practice is under the jurisdiction of ASTM Committee E08 on Fatigue and
product (for example, plate, bar, casting, and so forth); heat
Fracture and is the direct responsibility of E08.05 E08.05 on Cyclic Deformation
number; melting practice; last mechanical working and last
and Fatigue Crack Formation.
Current edition approved Nov. 1, 2023. Published January 2024. Originally
approved in 1972. Last previous edition approved in 2023 as E468/E468M –23.
3
DOI: 10.1520/E0468_E0468M-23A. The last approved version of this historical standard is referenced on
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or www.astm.org.
4
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM A Guide for Fatigue Testing and the Statistical Analysis of Fatigue Data,
Standards volume information, refer to the standard’s Document Summary page on ASTM International, 1963.
5
the ASTM website. Manual on Statistical Planning and Analysis, ASTM International, 1975.,
Copyright © ASTM Inte
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E468/E468M − 23 E468/E468M − 23a
Standard Practice for
Presentation of Constant Amplitude Fatigue Test Results for
1
Metallic Materials
This standard is issued under the fixed designation E468/E468M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This practice covers the desirable and minimum information to be communicated between the originator and the user of data
derived from constant-force amplitude axial, bending, or torsion fatigue tests of metallic materials tested in air and at room
temperature.
NOTE 1—Practice E466, although not directly referenced in the text, is considered important enough to be listed in this standard.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used
independently of the other, and values from the two systems shall not be combined.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
E6 Terminology Relating to Methods of Mechanical Testing
E8/E8M Test Methods for Tension Testing of Metallic Materials
E466 Practice for Conducting Force Controlled Constant Amplitude Axial Fatigue Tests of Metallic Materials
E467 Practice for Verification of Constant Amplitude Dynamic Forces in an Axial Fatigue Testing System
E739 Guide for Statistical Analysis of Linear or Linearized Stress-Life (S-N) and Strain-Life (ε-N) Fatigue Data (Withdrawn
3
2024)
E1823 Terminology Relating to Fatigue and Fracture Testing
1
This practice is under the jurisdiction of ASTM Committee E08 on Fatigue and Fracture and is the direct responsibility of E08.05 E08.05 on Cyclic Deformation and
Fatigue Crack Formation.
Current edition approved May 15, 2023Nov. 1, 2023. Published June 2023January 2024. Originally approved in 1972. Last previous edition approved in 20182023 as
E468E468/E468M —18. DOI: 10.1520/E0468_E0468M-23. –23. DOI: 10.1520/E0468_E0468M-23A.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
The last approved version of this historical standard is referenced on www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E468/E468M − 23a
2.2 Special Technical Publications:
4
STP 91–A A Guide for Fatigue Testing and the Statistical Analysis of Fatigue Data
5
STP 588 Manual on Statistical Planning and Analysis
3. Terminology Definitions and Nomenclature
3.1 The terms and abbreviations used in this practice are defined in Terminology E6 and in Terminology E1823.
4. Significance and Use
4.1 Fatigue test results may be significantly influenced by the properties and history of the parent material, the operations
performed during the preparation of the fatigue specimens, and the testing machine and test procedures used during the generation
of the data. The presentation of fatigue test results should include citation of basic information on the material, specimens, and
testing to increase the utility of the results and to reduce to a minimum the possibility of misinterpretation or improper application
of those results.
5. Listing of Basic Information About Fatigue Test Specimen
5.1 Specification and Properties of Material:
5.1.1 Material Prior to Fatigue Test Specimen Preparation—The minimum information to be presented should include the
designation or specification (for example,
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.