Standard Test Method for Extrudability of Oil- and Resin-Base Caulking Compounds

SIGNIFICANCE AND USE
4.1 The rate of extrusion determined by this test may be correlated with the rate of gunning of the compound.
SCOPE
1.1 This test method describes the laboratory procedure for determining the rate of extrusion of oil- and resin-base caulking compounds.  
1.2 The values stated in metric (SI) units are to be regarded as the standard. The values given in parentheses are provided for information only.  
1.3 The subcommittee with jurisdiction is not aware of any similar ISO standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-May-2015
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D2452-15 - Standard Test Method for Extrudability of Oil- and Resin-Base Caulking Compounds
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D2452-15 - Standard Test Method for Extrudability of Oil- and Resin-Base Caulking Compounds
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D2452 − 15
Standard Test Method for
1
Extrudability of Oil- and Resin-Base Caulking Compounds
This standard is issued under the fixed designation D2452; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 5.2 Air Supply and Pressure Gage, accurate to 6.9 kPa (1
psi).
1.1 This test method describes the laboratory procedure for
determining the rate of extrusion of oil- and resin-base caulk- 5.3 Clamps and Stand to hold rheometer.
ing compounds.
5.4 Balance, accurate to 0.01 g.
1.2 The values stated in metric (SI) units are to be regarded
5.5 Stopwatch.
as the standard. The values given in parentheses are provided
5.6 Spatula (Steel).
for information only.
3
5.7 Weight-per-gallon Cup, capacity 83.2 cm .
1.3 The subcommittee with jurisdiction is not aware of any
similar ISO standard.
6. Reagent
1.4 This standard does not purport to address all of the
6.1 Solvent, such as methyl ethyl ketone.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
7. Sampling
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use. 7.1 The compound to be tested shall be taken from a
previously unopened container and thoroughly mixed before
2. Referenced Documents
using.
2
2.1 ASTM Standards:
8. Conditioning
C717Terminology of Building Seals and Sealants
D1475Test Method For Density of Liquid Coatings, Inks,
8.1 Afterthoroughlycleaningthepress-flowrheometerwith
and Related Products
solvent, condition the compound and the rheometer in the
laboratory for at least5hat standard conditions.
3. Terminology
3.1 Definitions—Definitions of the following terms are
9. Procedure
found in Terminology C717: caulking compound, compound,
9.1 Remove the orifice holder from the rheometer cylinder
sealant, standard conditions.
and hold the open end up, making sure that the follower plate
remains inside.
4. Significance and Use
9.2 Fill the cylinder with compound, avoiding air pockets.
4.1 The rate of extrusion determined by this test may be
Strike off the filled cylinder with a spatula and replace the
correlated with the rate of gunning of the compound.
bottom orifice cap. Connect the tube to an air supply and fix it
to a support stand above the balance.
5. Apparatus
9.3 Adjust the air pressure to 207 kPa (30 psi) and open the
5.1 Press-Flow Extrusion Rheometer constructed in accor-
air valve. If the pressure drops, readjust to 207 kPa while
dance with Fig. 1.
extrusion is in progress. Close the air valve and discard this
extruded compound. The apparatus is now ready for testing.
1
ThistestmethodisunderthejurisdictionofASTMCommitteeC24onBuilding
9.4 Open the air valve and start the stopwatch simultane-
Seals and Sealants and is the direct responsibility of Subcommittee C24.20 on
General Test Methods.
ously.After extruding approximately 50 g of compound, close
CurrenteditionapprovedJune1,2015.PublishedJuly2015.Originallyapproved
the air valve and stop the stopwatch simultaneously. Weigh to
in 1966. Last previous edition approved in 2009 as D2452–03(2009). DOI:
the nearest 0.01 g the amount of compound extruded.
10.1520/D2452-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
9.5 Calculate the seconds per gram by dividing the number
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
of seconds elapsed by the number of grams extruded, and
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. designate this as value S.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D2452 − 15
2
FIG. 1 Press-Flow Extrusion Rheometer

---------------------- Page: 2 ----------------------
D2452 − 15
9.6 Convert the value S to seconds per millilitre after E 5 S 3D (1)
determining the specific gravity of the compound using the
where:
weight-per-gallon cup and Test Method D1475.
S = seconds per gram, and
NOTE 1—Since different compounds have different specific gravities,
D = specific gravity=weight⁄gallon (in pounds) ×0.12.
and the extrusion rate in terms of volume normally is of greater interest
than in terms of weight, the results shall be converted to terms of seconds
12. Report
per millilitre.
12.1 Report the extrudability, in seconds per millilitre.
10. Specific Gravity
13. Precision and Bias
10.1 Weigh the weight-per-gallon cup accurately to 0.1 g.
13.1 On the basis of a round-robin in which six laboratories
10.2 Remo
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D2452 − 03 (Reapproved 2009) D2452 − 15
Standard Test Method for
1
Extrudability of Oil- and Resin-Base Caulking Compounds
This standard is issued under the fixed designation D2452; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method describes the laboratory procedure for determining the rate of extrusion of oil- and resin-base caulking
compounds.
1.2 The values stated in metric (SI) units are to be regarded as the standard. The values given in parentheses are provided for
information only.
1.3 The subcommittee with jurisdiction is not aware of any similar ISO standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C717 Terminology of Building Seals and Sealants
D1475 Test Method For Density of Liquid Coatings, Inks, and Related Products
3. Terminology
3.1 Definitions—Definitions of the following terms are found in Terminology C717: caulking compound, compound, sealant.
sealant, standard conditions.
4. Significance and Use
4.1 The rate of extrusion determined by this test may be correlated with the rate of gunning of the compound.
5. Apparatus
5.1 Press-Flow Extrusion Rheometer constructed in accordance with Fig. 1.
5.2 Air Supply and Pressure Gage, accurate to 6.9 kPa (1 psi).
5.3 Clamps and Stand to hold rheometer.
5.4 Balance, accurate to 0.01 g.
5.5 Stop Watch. Stopwatch.
5.6 Spatula (Steel).
3
5.7 Weight-per-gallon Cup, capacity 83.2 cm .
6. Reagent
6.1 Solvent, such as methyl ethyl ketone.
1
This test method is under the jurisdiction of ASTM Committee C24 on Building Seals and Sealants and is the direct responsibility of Subcommittee C24.20 on General
Test Methods.
Current edition approved Jan. 1, 2009June 1, 2015. Published March 2009July 2015. Originally approved in 1966. Last previous edition approved in 20032009 as
D2452 – 03.D2452 – 03(2009). DOI: 10.1520/D2452-03R09.10.1520/D2452-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D2452 − 15
2
FIG. 1 Press-Flow Extrusion Rheometer

---------------------- Page: 2 ----------------------
D2452 − 15
7. Sampling
7.1 The compound to be tested shall be taken from a previously unopened container and thoroughly mixed before using.
8. Conditioning
8.1 After thoroughly cleaning the press-flow rheometer with solvent, condition the compound and the rheometer in the
laboratory for at least 5 h at 23 6 2°C (73.4 6 3.6°F).standard conditions.
9. Procedure
9.1 Remove the orifice holder from the rheometer cylinder and hold the open end up, making sure that the follower plate
remains inside.
9.2 Fill the cylinder with compound, avoiding air pockets. Strike off the filled cylinder with a spatula and replace the bottom
orifice cap. Connect the tube to an air supply and fix it to a support stand above the balance.
9.3 Adjust the air pressure to 207 kPa (30 psi) and open the air valve. If the pressure drops, readjust to 207 kPa while extrusion
is in progress. Close the air valve and discard this extruded compound. The apparatus is now ready for testing.
9.4 Open the air valve and start the stop watch stopwatch simultaneously. After extruding approximately 50 g of compound,
close the air valve and stop the stop watch stopwatch simultaneously. Weigh to the nearest 0.01 g the amount of compound
extruded.
9.5 Calculate the seconds per gram by dividing the number of seconds elapsed by the number of grams extruded, and designate
this as value S.
9.6 Convert the value S to seconds per millilitre after determining the specific gravity of the compound using the
weight-per-gallon cup and Test Method D1475.
NOTE 1—Since different compounds have different specific gravities, and the extrusion rate in terms of volume no
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.