Standard Specification for Sliding Watertight Door Assemblies

ABSTRACT
This specification covers the design, manufacture, and testing of sliding watertight door assemblies intended to ensure the watertight integrity of personnel access openings in watertight bulkheads. Sliding watertight doors consist of four types: type IA - horizontal doors, type IB - vertical doors, type IIA - horizontal doors, and type IIB - vertical doors. Watertight doors consist of three classes: class 1 - doors that are hinged and dogged, class 2 - sliding doors that are operable both locally and remotely by hand gear, and class 3 - sliding doors that are operable both locally and remotely by hand and by power. Hydrostatic test and visual examination shall be performed to meet the requirements prescribed.
SCOPE
1.1 This specification covers the design, manufacture, and testing of sliding watertight door assemblies intended to ensure the watertight integrity of personnel access openings in watertight bulkheads.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

General Information

Status
Historical
Publication Date
14-Jan-2008
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1196-00(2008) - Standard Specification for Sliding Watertight Door Assemblies
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F1196-00(2008) - Standard Specification for Sliding Watertight Door Assemblies
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F1196 −00(Reapproved 2008) An American National Standard
Standard Specification for
Sliding Watertight Door Assemblies
This standard is issued under the fixed designation F1196; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2.5 International Maritime Organization (IMO):
International Code for the Application of Fire Test Proce-
1.1 This specification covers the design, manufacture, and
dures (FTP)
testing of sliding watertight door assemblies intended to ensure
the watertight integrity of personnel access openings in water-
3. Terminology
tight bulkheads.
3.1 Definitions:
1.2 The values stated in inch-pound units are to be regarded
3.1.1 door assembly—a door panel and its associated panel
as the standard. The values given in parentheses are for
stiffening.
information only.
3.1.2 frameassembly—arigidframedesignedtobeattached
to a watertight bulkhead. The guide tracks necessary to ensure
2. Referenced Documents
proper door and frame alignment are also included as part of
the frame assembly.
2.1 ASTM Standards:
3.1.3 horizontal sliding watertight door—a sliding water-
A36/A36M Specification for Carbon Structural Steel
tight door that opens and closes with a horizontal movement.
F1197 Specification for Sliding Watertight Door Control
3.1.4 opening hand—the direction in which a horizontal
Systems
sliding watertight door opens. A left-hand opening door opens
2.2 Military Specification:
totheleftwhenviewedfromthesideofthebulkheadonwhich
MIL-S-901 Shock Test, H.I. (High Impact); Shipboard
the door assembly is located.Aright-hand opening door opens
Machinery, Equipment and Systems, Requirements for
to the right when viewed from the side of the bulkhead on
2.3 American Bureau of Shipping: which the door assembly is located.
Rules for Building and Classing Steel Vessels
3.1.5 pressurehead—thepressurewhichaslidingwatertight
door assembly is designed to withstand. For a door located
2.4 Code of Federal Regulations:
below the bulkhead deck, it is equivalent to the pressure
Title 46, Part 159.010, Independent Laboratory:Acceptance,
exertedbyacolumnofwatertheheightofwhichisequaltothe
Listing and Termination
vertical distance from the bulkhead deck to the door sill in its
Title 46, Part 163.001, Doors, Watertight, Sliding (and Door
installed location. For a door located above the bulkhead deck,
Controls),forMerchantVessels(throughthe1991edition)
itisequivalenttothepressureexertedbythemaximumheadof
water for its location, as determined in the damage stability
calculations.
This specification is under the jurisdiction of Committee F25 on Ships and
3.1.6 sliding watertight door assembly—a steel door assem-
Marine Technology and is the direct responsibility of Subcommittee F25.03 on
Outfitting and Deck Machinery. bly and a steel frame assembly fitted with a replaceable
Current edition approved Jan. 15, 2008. Published January 2008. Originally
interface between the two that ensures watertightness between
approved in 1989. Last previous edition approved in 2000 as F1196 - 00. DOI:
door and frame at the design pressure head.
10.1520/F1196-00R08.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
3.1.7 vertical sliding watertight door—a sliding watertight
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
door that opens and closes with a vertical movement.
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, 4. Classification
Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http://
4.1 Sliding watertight doors consist of four types:
www.dodssp.daps.mil.
Available from American Bureau of Shipping (ABS), ABS Plaza, 16855
Northchase Dr., Houston, TX 77060, http://www.eagle.org.
AvailablefromU.S.GovernmentPrintingOfficeSuperintendentofDocuments,
732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:// AvailablefromtheInternationalMaritimeOrganization,4AlbertEmbankment,
www.access.gpo.gov. London, SE1 7SR UK.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F1196−00 (2008)
4.1.1 Type IA—Horizontal doors that conform to the sizes
specified in Table 1 as illustrated in Fig. 1.
4.1.2 Type IB—Vertical doors that conform to the sizes
specified in Table 2 as illustrated in Fig. 2.
4.1.3 Type IIA—Horizontal doors that conform generally to
the requirements of this specification, but that necessitate
special requirements as indicated in Section 5.
4.1.4 Type IIB—Vertical doors that conform generally to the
requirements of this specification, but that necessitate special
requirements as indicated in Section 5.
4.2 Watertight doors consist of three classes:
NOTE 1—These classifications are in agreement with those defined and
accepted by the International Convention for the Safety of Life at Sea
(SOLAS), regulatory bodies, and classification societies.
4.2.1 Class 1—Doors that are hinged and dogged. This
specification is not applicable to this class of door.
4.2.2 Class 2—Sliding doors that are operable both locally
and remotely by hand gear.
4.2.3 Class 3—Sliding doors that are operable both locally
and remotely by hand and by power.
5. Ordering Information
5.1 The following shall be specified when ordering:
5.1.1 Quantity,
5.1.2 Type,
FIG. 1 Type IA Door and Frame
5.1.3 Class,
5.1.4 Size,
TABLE 2 Type IB Door Dimensions
5.1.5 Opening hand,
A, B, C, D, E,
Size Door Size
A
in. in. in. in. in.
5.1.6 Door and frame material,
5.1.7 Pressure head (if other than standard), 1 2 ft. 2 in. by 5 ft. 6 in. 26 66 142 155 17
2 2 ft. 6 in. by 5 ft. 0 in. 30 60 130 143 16
5.1.8 Supplementary requirements (if any),
3 2 ft. 6 in. by 6 ft. 0 in. 30 72 154 167 18
5.1.9 Additional requirements as contracted by the manu-
4 3 ft. 0 in. by 5 ft. 6 in. 36 66 142 155 18
facturer and purchaser, and
A
1 in. = 25.4 mm.
5.1.10 ASTM specification designation.
6. Design
6.3.1 Thereplaceableinterfacemaybeincorporatedintothe
6.1 Sliding watertight door assemblies shall be designed to
door assembly, the frame assembly, or both.
maintain watertightness within the limits set forth in this
6.3.2 Assemblies shall be designed and constructed so as to
specification. Doors shall be designed to open and close within
be capable of preventing the passage of smoke and flame to the
the limitations specified in Specification F1197.
end of the 1-h standard fire test described by IMO FTP. When
specified by the purchaser, assemblies shall also be insulated to
6.2 Assembliesshallbeofsubstantialandrigidconstruction
prevent the transfer of heat to at least the same degree as the
to ensure that doors can be closed under a static head
adjacent bulkhead. A fire test is not required if the assembly
equivalent to a water height of at least 1 m above the sill on the
design incorporates details that have been demonstrated such
centerline of the door.
as by a fire test on a similar door with smaller dimensions, to
6.3 There shall be a replaceable interface between the door
prevent the passage of smoke and flame. Also, a separate
and frame assemblies, such as a brass rubbing strip or resilient
pressure test to determine continued watertightness after the
gasket, to ensure watertightness between door and frame at the
standard fire test is not required.
design pressure head.
6.3.3 Assembles shall be designed in such a manner that the
replaceable interface will be protected from damage when the
TABLE 1 Type IA Door Dimensions
door is in the open position.
A, B, C, D, E, F,
Size Door Size
A 6.4 Sliding watertight door assemblies shall be designed to
in. in. in. in. in. in.
provide sufficient allowance or means of adjustment to main-
1 2 ft. 2 in. by 5 ft. 6 in. 26 66 64 76 17 78
2 2 ft. 6 in. by 5 ft. 0 in. 30 60 72 84 16 72 tain the original watertight integrity as the watertight joint
3 2 ft. 6 in. by 6 ft. 0 in. 30 72 72 84 18 84
wears through normal usage.
4 3 ft. 0 in. by 5 ft. 6 in. 36 66 84 96 18 78
A 6.5 Means shall be provided for lubrication of all parts
1 in. = 25.4 mm.
necessary for satisfactory operation.
F1196−00 (2008)
6.8.4 Thebottomoftheframeassemblyshallbedesignedso
the door will not be prevented from closing properly by
lodgements of dirt or debris.
6.8.5 Asill plate of ⁄16-in. (5-mm) minimum thickness may
beusedtocoverthebottomtrackwayprovideditisdesignedto
retract automatically when the door closes. Sill plate hinges
shall be designed and located to prevent clogging with dirt.
6.9 Actuating Component Attachments— Assemblies shall
be fitted with the necessary attachments for actuating compo-
nents and controls.
6.9.1 Door control systems shall comply with the require-
ments of Specification F1197.
7. Materials and Manufacture
7.1 Materials:
7.1.1 Thedoorpanel,panelstiffness,doorframe,tracks,and
all attachments affecting watertight integrity shall be made of
a material accepted in the Rules for Building and Classing
SteelVesselsoftheAmericanBureauofShipping(ABSRules)
for use in the fabrication of watertight subdivision bulkheads,
for example, Specification A36/A36M steel. Special consider-
ation shall be given to the choice of materials for components
exposed to corrosive environments such as on assemblies
located in engine rooms and cargo holds.
FIG. 2 Type IB Door and Frame
7.1.2 All fasteners shall be brass or stainless steel suitable
for the purpose intended.
7.2 Manufacture:
7.2.1 All welding of the door frame shall be continuous.
6.6 Sliding watertight door assemblies shall have a maxi-
Door panel stiffeners may be attached by intermittent welding.
mum horizontal opening of 48 in. (122 cm).
All welding shall be in accordance with the requirements of
6.7 Door Assemblies—Type I (standard) doors are designed
Part I, Section 30 of the ABS Rules.
for a pressure head of 20 ft (6 m) of water. Type II (nonstan-
7.2.2 All load-bearing main structural components of the
dard) doors shall be designed for the pressure head as specified
door and frame shall have a minimum thickness of ⁄4 in. (7
in 3.1.5 and 5.1.7, but not less than 20 ft (6 m) for doors
mm).
installed below the bulkhead deck.
7.2.3 The contact surfaces of the door and frame shall be
6.7.1 The door panel and panel stiffener assembly shall be
finished as necessary to provide a plane surface and a joint that
designed based on 40 % of the yield strength of the material
meets the requirements of this specification. Cast doors and
used to construct the panel and its stiffeners (see 7.1).
frames, and doors and frames fabricated by welding, shall be
6.7.2 The door panel and stiffener assembly shall have a
thermally stress relieved before final machine work is per-
maximum de
...


This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation:F 1196–94 (Reapproved 2000) Designation: F 1196 – 00 (Reapproved 2008)
Standard Specification for
Sliding Watertight Door Assemblies
This standard is issued under the fixed designation F 1196; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers the design, manufacture, and testing of sliding watertight door assemblies intended to ensure the
watertight integrity of personnel access openings in watertight bulkheads.
1.2 Thevaluesstatedininch-poundunitsaretoberegardedasthestandard.Thevaluesgiveninparenthesesareforinformation
only.
2. Referenced Documents
2.1 ASTM Standards:
A 36/A 36M Specification for Carbon Structural Steel
F 1197 Specification for Sliding Watertight Door Control Systems
2.2 Military Specification:
MIL-S-901 Shock Test, H.I. (High Impact); Shipboard Machinery, Equipment and Systems, Requirements for
2.3 American Bureau of Shipping:
Rules for Building and Classing Steel Vessels
2.4 Code of Federal Regulations:
Title 46, Part 159.010, Independent Laboratory: Acceptance, Listing and Termination
Title 46, Part 163.001, Doors, Watertight, Sliding (and Door Controls), for Merchant Vessels (through the 1991 edition)
2.5 International Maritime Organization (IMO):
Assembly ResolutionA.517(13),Recommendation on Fire Test Procedures for“A,” “B,” and “F” Class Divisions International
Code for the Application of Fire Test Procedures (FTP)
3. Terminology
3.1 Definitions:
3.1.1 door assembly—a door panel and its associated panel stiffening.
3.1.2 frame assembly—a rigid frame designed to be attached to a watertight bulkhead. The guide tracks necessary to ensure
proper door and frame alignment are also included as part of the frame assembly.
3.1.3 horizontal sliding watertight door—a sliding watertight door that opens and closes with a horizontal movement.
3.1.4 opening hand—the direction in which a horizontal sliding watertight door opens. A left-hand opening door opens to the
left when viewed from the side of the bulkhead on which the door assembly is located. A right-hand opening door opens to the
right when viewed from the side of the bulkhead on which the door assembly is located.
3.1.5 pressure head—the pressure which a sliding watertight door assembly is designed to withstand. For a door located below
the bulkhead deck, it is equivalent to the pressure exerted by a column of water the height of which is equal to the vertical distance
This specification is under the jurisdiction of Committee F-25 on Ships and Marine Technology and is the direct responsibility of Subcommittee F25.03 on Outfitting.
Current edition approved Oct. 15, 1994. Published December 1994. Originally published as F1196–89. Last previous edition F1196–89.
This specification is under the jurisdiction of Committee F25 on Ships and Marine Technology and is the direct responsibility of Subcommittee F25.03 on Outfitting and
Deck Machinery.
Current edition approved Jan. 15, 2008. Published January 2008. Originally approved in 1989. Last previous edition approved in 2000 as F1196 - 00.
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
, Vol 01.04.volume information, refer to the standard’s Document Summary page on the ASTM website.
Annual Book of ASTM Standards, Vol 01.07.
Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http://www.dodssp.daps.mil.
Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700 Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Available from American Bureau of Shipping (ABS), ABS Plaza, 16855 Northchase Dr., Houston, TX 77060, http://www.eagle.org.
Available from American Bureau of Shipping, ABS Plaza, 16855 Northchase Dr., Houston, TX 77060.
Available from U.S. Government Printing Office Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http://
www.access.gpo.gov.
Available from Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402.
Available from the International Maritime Organization, 4 Albert Embankment, London, SE1 7SR UK.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
F 1196 – 00 (2008)
from the bulkhead deck to the door sill in its installed location. For a door located above the bulkhead deck, it is equivalent to the
pressure exerted by the maximum head of water for its location, as determined in the damage stability calculations.
3.1.6 sliding watertight door assembly—a steel door assembly and a steel frame assembly fitted with a replaceable interface
between the two that ensures watertightness between door and frame at the design pressure head.
3.1.7 vertical sliding watertight door—a sliding watertight door that opens and closes with a vertical movement.
4. Classification
4.1 Sliding watertight doors consist of four types:
4.1.1 Type IA—Horizontal doors that conform to the sizes specified in Table 1 as illustrated in Fig. 1.
4.1.2 Type IB—Vertical doors that conform to the sizes specified in Table 2 as illustrated in Fig. 2.
4.1.3 Type IIA—Horizontal doors that conform generally to the requirements of this specification, but that necessitate special
requirements as indicated in Section 5.
4.1.4 Type IIB—Vertical doors that conform generally to the requirements of this specification, but that necessitate special
requirements as indicated in Section 5.
4.2 Watertight doors consist of three classes:
NOTE 1—TheseclassificationsareinagreementwiththosedefinedandacceptedbytheInternationalConventionfortheSafetyofLifeatSea(SOLAS),
regulatory bodies, and classification societies.
4.2.1 Class 1—Doors that are hinged and dogged. This specification is not applicable to this class of door.
4.2.2 Class 2—Sliding doors that are operable both locally and remotely by hand gear.
4.2.3 Class 3—Sliding doors that are operable both locally and remotely by hand and by power.
5. Ordering Information
5.1 The following shall be specified when ordering:
5.1.1 Quantity,
5.1.2 Type,
5.1.3 Class,
5.1.4 Size,
5.1.5 Opening hand,
5.1.6 Door and frame material,
5.1.7 Pressure head (if other than standard),
5.1.8 Supplementary requirements (if any),
5.1.9 Additional requirements as contracted by the manufacturer and purchaser, and
5.1.10 ASTM specification designation.
6. Design
6.1 Sliding watertight door assemblies shall be designed to maintain watertightness within the limits set forth in this
specification. Doors shall be designed to open and close within the limitations specified in Specification F 1197.
6.2Assemblies shall be of substantial and rigid construction to ensure that doors can be closed under the design pressure head.
6.2 Assemblies shall be of substantial and rigid construction to ensure that doors can be closed under a static head equivalent
to a water height of at least 1 m above the sill on the centerline of the door.
6.3 There shall be a replaceable interface between the door and frame assemblies, such as a brass rubbing strip or resilient
gasket, to ensure watertightness between door and frame at the design pressure head.
6.3.1 The replaceable interface may be incorporated into the door assembly, the frame assembly, or both.
6.3.2Assemblies shall be designed and constructed so as to be capable of preventing the passage of smoke and flame, and heat
when specified by the purchaser, to the end of the 1-h standard fire test described by IMO Assembly Resolution A.517(13) to at
least the same degree as the adjacent bulkhead.Afire test is not required if the assembly design incorporates details that have been
demonstrated to prevent the passage of smoke and flame.
6.3.2 Assemblies shall be designed and constructed so as to be capable of preventing the passage of smoke and flame to the
end of the 1-h standard fire test described by IMO FTP. When specified by the purchaser, assemblies shall also be insulated to
TABLE 1 Type IA Door Dimensions
A, B, C, D, E, F,
Size Door Size
A
in. in. in. in. in. in.
1 2 ft. 2 in. by 5 ft. 6 in. 26 66 64 76 17 78
2 2 ft. 6 in. by 5 ft. 0 in. 30 60 72 84 16 72
3 2 ft. 6 in. by 6 ft. 0 in. 30 72 72 84 18 84
4 3 ft. 0 in. by 5 ft. 6 in. 36 66 84 96 18 78
A
1 in. = 25.4 mm.
F 1196 – 00 (2008)
FIG. 1 Type IA Door and Frame
TABLE 2 Type IB Door Dimensions
A, B, C, D, E,
Size Door Size
A
in. in. in. in. in.
1 2 ft. 2 in. by 5 ft. 6 in. 26 66 142 155 17
2 2 ft. 6 in. by 5 ft. 0 in. 30 60 130 143 16
3 2 ft. 6 in. by 6 ft. 0 in. 30 72 154 167 18
4 3 ft. 0 in. by 5 ft. 6 in. 36 66 142 155 18
A
1 in. = 25.4 mm.
prevent the transfer of heat to at least the same degree as the adjacent bulkhead. A fire test is not required if the assembly design
incorporates details that have been demonstrated such as by a fire test on a similar door with smaller dimensions, to prevent the
passage of smoke and flame.Also, a separate pressure test to determine continued watertightness after the standard fire test is not
required.
6.3.3 Assembles shall be designed in such a manner that the replaceable interface will be protected from damage when the door
is in the open position.
6.4 Sliding watertight door assemblies shall be designed to provide sufficient allowance or means of adjustment to maintain the
original watertight integrity as the watertight joint wears through normal usage.
6.5 Means shall be provided for lubrication of all parts necessary for satisfactory operation.
6.6 Sliding watertight door assemblies shall have a maximum horizontal opening of 48 in. (122 cm).
6.7 Door Assemblies—Type I (standard) doors are designed for a pressure head of 20 ft (6 m) of water. Type II (nonstandard)
doors shall be designed for the pressure head as specified in 3.1.5 and 5.1.7, but not less than 20 ft (6 m) for doors installed below
the bulkhead deck.
6.7.1 The door panel and panel stiffener assembly shall be designed based on 40 % of the yield strength of the material used
to construct the panel and its stiffeners (see 7.1).
6.7.2 The door panel and stiffener assembly shall have a maximum deflection of span/240.
6.7.3 Retaining grooves or aligning strips shall be provided at the tops and bottoms of horizontal assemblies and at the sides
of vertical assemblies to maintain doors in proper alignment when they are not in the closed position.
6.8 Frame Assemblies—The door frame shall be continuous on all four sides. The door frame shall be of sufficient rigidity to
maintain a watertight seal under the applicable operating conditions and the design head as specified in 6.7.
6.8.1 If the door frame is to be welded to the bulkhead on a reinforcing member, which acts as a secondary frame and which
is continuous around the door opening, the I of that member may be included to obtain the required frame I value. (See also the
Appendix X1.)
F 1196 – 00 (2008)
FIG. 2 Type IB Door and Frame
6.8.2 The frame extension for sliding watertight doors shall be made in one continuous piece, or suitable construction shall be
used to ensure proper alignment.
6.8.3 Horizontal doors shall be supported by lubricated rollers to maintain alignment and minimize friction.
6.8.4 The bottom of the frame assembly shall be designed so the door will not be prevented from closing properly by
lodgements of dirt or debris.
6.8.5 A sill plate of ⁄16-in. (5-mm) minimum thickness may be used to cover the bottom trackway provided it is designed to
retract automatically when the door closes. Sill plate hinges shall be designed and located to prevent clogging with dirt.
6.9 Actuating Component Attachments— Assemblies shall be fitted with the necessary attachments for actuating components
and controls.
6.9.1 Door control systems shall comply with the requirements of Specification F 1197.
7. Materials and Manufacture
7.1 Materials:
7.1.1 The door panel, panel stiffness, door frame, tracks, and all attachments affecting watertight integrity shall be made of a
material accepted in the Rules for Building and Classing Steel Vessels of the American Bureau of Shipping (ABS Rules) for use
in the fabrication of watertight subdivision bulkheads, for example, SpecificationA 36/A 36M steel. Special consideration shall be
given to the choice of materials for components exposed to corrosive environments such as on assemblies located in engine rooms
and cargo holds.
7.1.2 All fasteners shall be brass or stainless steel suitable for the purpose intended.
7.2 Manufacture:
7.2.1 All welding of the door frame shall be continuous. Door panel stiffeners may be attached by intermittent welding. All
welding shall be in accordance with the requirements of Part I, Section 30 of the ABS Rules.
7.2.2 All load-bearing main structural components of the door and frame shall have a minimum thickness of ⁄4 in. (7 mm).
7.2.3 The contact surfaces of the door and frame shall be finished as necessary to provide a plane surface and a joint that meets
the requirements of this specification. Cast doors and frames, and doors and frames fabricated by welding, shall be thermally stress
relieved before final machine work is performed.
8. Workmanship, Finish, and Appearance
8.1 All sharp and ragged edges shall be ground flush and removed.
8.2 Door, frame, and guide rail assemblies shall be abrasive blasted to “near white” metal in accordance with good commercial
practice and coated with a nonhazardous primer.
9. Inspection and Testing of Doors
9.1 Shop Tests and Inspections (see also the Supplementary Requirements ):
F 1196 – 00 (2008)
9.1.1 Visual Examination—Each completed door and frame shall be examined for quality workmanship and to assure
conformance to design plans and this specification.
9.1.2 Hydrostatic Test—Each completed sliding watertight door assembly shall be subjected to a hydrostatic shop test to verify
its strength, rigidity, workmanship, and watertightness.
9.1.2.1 Hydrostatic Test Setup—Thedoorframeshallbemountedineitheraverticalorhorizontallyflatpositiononareinforced
test pl
...