Standard Specification for Concrete Drain Tile (Metric)

ABSTRACT
This specification covers concrete drain tile, to be used for surface and subsurface drainage. Manufactured drain tile shall be of the following classes: standard-quality concrete drain tile, extra-quality concrete drain tile, heavy-duty extra-quality concrete drain tile, and special-quality concrete drain tile. The concrete shall consist of mineral aggregates, water, and cementitious materials that include Portland cement, fly ash, ground granulated blast furnace slag, aggregates, admixtures and blends, and synthetic fibers. Concrete drain tile shall meet the physical requirement of the specification according to class, depending on soil acidity and sulfate content. Test specimens shall meet the external load crushing strength test requirement of the specification.
SCOPE
1.1 This specification covers concrete drain tile with internal diameters from 100 to 900 mm, that are intended to be used for surface and subsurface drainage.
1.2 This specification is the metric counterpart of Specification C412.
Note 1—This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or require inspection at the construction site.

General Information

Status
Historical
Publication Date
31-Aug-2011
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C412M-11 - Standard Specification for Concrete Drain Tile (Metric)
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C412M-11 - Standard Specification for Concrete Drain Tile (Metric)
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C412M −11
StandardSpecification for
1
Concrete Drain Tile (Metric)
This standard is issued under the fixed designation C412M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope 4. Classification
1.1 This specification covers concrete drain tile with inter-
4.1 Drain tile manufactured according to this specification
nal diameters from 100 to 900 mm, that are intended to be used
shall be of the following four classes:
for surface and subsurface drainage.
4.1.1 Standard-Quality Concrete Drain Tile, intended for
1.2 This specification is the metric counterpart of Specifi-
land drainage of ordinary soils where the tile are laid in
cation C412.
trenches of moderate depths and widths. Standard-Quality
concrete drain tile are not recommended for use where internal
NOTE 1—This specification is a manufacturing and purchase specifica-
tion only and does not include requirements for bedding, backfill, or the
diameters in excess of 300 mm are required.
relationship between field load condition and the strength classification of
4.1.2 Extra-Quality Concrete Drain Tile, intended for land
draintile.However,experiencehasshownthatthesuccessfulperformance
drainage of ordinary soils where the tile are laid in trenches of
of the product depends upon the proper selection of the class of drain tile,
type of bedding and backfill, and care that the installation conforms to the
considerable depths or widths, or both.
construction specifications. The owner is cautioned that he must correlate
4.1.3 Heavy-Duty Extra-Quality Concrete Drain Tile, in-
the field requirements with the class of drain tile specified and provide for
tendedforlanddrainageofordinarysoilswherethetilearelaid
or require inspection at the construction site.
in trenches of large depths or widths, or both.
2. Referenced Documents
4.1.4 Special-Quality Concrete Drain Tile,intendedforland
2
2.1 ASTM Standards:
drainage where special precautions are necessary for concrete
C33 Specification for Concrete Aggregates
tile laid in soils that are markedly acid or contain unusual
C150 Specification for Portland Cement
quantities of sulfates (see Section 7), and where the tile are laid
C497M Test Methods for Concrete Pipe, Manhole Sections,
in trenches of considerable depths or widths, or both.
or Tile [Metric]
4.1.4.1 Where the calculated loads are in excess of the
C595 Specification for Blended Hydraulic Cements
crushing strengths prescribed in the physical requirements for
C618 Specification for Coal Fly Ash and Raw or Calcined
extra-quality and special-quality concrete drain tile, tile
Natural Pozzolan for Use in Concrete
strengths must be specified in advance by the owner.
C822 Terminology Relating to Concrete Pipe and Related
Products
5. Basis of Acceptance
C989 Specification for Slag Cement for Use in Concrete and
Mortars
5.1 The acceptability of drain tile shall be determined by (1)
C1116 Specification for Fiber-Reinforced Concrete and
the results of the physical tests as specified in Section 8, and in
Shotcrete
Test Methods C497M,(2) measurements and inspection to
ascertain whether the tile conform to the requirements regard-
3. Terminology
ing dimensions, shape, and freedom from visible defects, and
3.1 Definitions—Fordefinitionsoftermsrelatingtoconcrete
(3) the manufacturer’s certification in writing that the tile have
pipe, see Terminology C822.
been made in accordance with any special provisions, such as
strength, absorption, permeability, type of cement, admixture,
1
This specification is under the jurisdiction of ASTM Committee C13 on
curing conditions, etc.
Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on
Non-Reinforced Concrete Sewer, Drain and Irrigation Pipe.
5.2 The owner shall specify in writing the class or classes of
Current edition approved Sept. 1, 2011. Published October 2011. Originally
concrete tile to be supplied, whether Standard-Quality, Extra-
approved in 1980. Last previous edition approved in 2005 as C412M – 05a. DOI:
10.1520/C0412M-11.
Quality, Heavy-Duty Extra-Quality, or Special-Quality. Unless
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Extra-Quality, Heavy-Duty Extra-Quality, or Special-Quality
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
concrete drain tile have been specified, Standard-Quality drain
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. tile shall be accepted.
Copyright © ASTM International, 100 Barr Harbor Drive, PO B
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C412M–05a Designation: C412M – 11
Standard Specification for
1
Concrete Drain Tile (Metric)
This standard is issued under the fixed designation C412M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope
1.1 This specification covers concrete drain tile with internal diameters from 100 to 900 mm, that are intended to be used for
surface and subsurface drainage.
1.2 This specification is the metric counterpart of Specification C412.
NOTE 1—This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the
relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of
the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the
construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or
require inspection at the construction site.
2. Referenced Documents
2
2.1 ASTM Standards:
C33 Specification for Concrete Aggregates
C150 Specification for Portland Cement
C497M Test Methods for Concrete Pipe, Manhole Sections, or Tile [Metric]
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C822 Terminology Relating to Concrete Pipe and Related Products
C989 Specification for Slag Cement for Use in Concrete and Mortars
C1116 Specification for Fiber-Reinforced Concrete and Shotcrete
3. Terminology
3.1 Definitions—For definitions of terms relating to concrete pipe, see Terminology C822.
4. Classification
4.1 Drain tile manufactured according to this specification shall be of the following four classes:
4.1.1 Standard-Quality Concrete Drain Tile, intended for land drainage of ordinary soils where the tile are laid in trenches of
moderate depths and widths. Standard-Quality concrete drain tile are not recommended for use where internal diameters in excess
of 300 mm are required.
4.1.2 Extra-Quality Concrete Drain Tile, intended for land drainage of ordinary soils where the tile are laid in trenches of
considerable depths or widths, or both.
4.1.3 Heavy-Duty Extra-Quality Concrete Drain Tile, intended for land drainage of ordinary soils where the tile are laid in
trenches of large depths or widths, or both.
4.1.4 Special-Quality Concrete Drain Tile, intended for land drainage where special precautions are necessary for concrete tile
laid in soils that are markedly acid or contain unusual quantities of sulfates (see Section 7), and where the tile are laid in trenches
of considerable depths or widths, or both.
4.1.4.1 Where the calculated loads are in excess of the crushing strengths prescribed in the physical requirements for
extra-quality and special-quality concrete drain tile, tile strengths must be specified in advance by the owner.
1
This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on Non-Reinforced
Concrete Sewer, Drain,Drain and Irrigation Pipe.
Current edition approved Dec.Sept. 1, 2005.2011. Published January 2006.October 2011. Originally approved in 1980. Last previous edition approved in 2005 as
C412M – 05a. DOI: 10.1520/C0412M-05A.10.1520/C0412M-11.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C412M – 11
5. Basis of Acceptance
5.1 The acceptability of drain tile shall be determined by (1) the results of the physical tests as specified in Section 8, and in
Test Methods C497M, (2) measurements and inspection to ascertain whether the tile conform to the requirements regarding
dimensions, shape, and freedom from visible defects, and (3) the manufacturer’s certification in writing that
...

Questions, Comments and Discussion