Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings

SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining system, and a form of marking for large diameters, 18 to 48 in. poly(vinyl chloride) (PVC) sewer pipe and fittings with integral bell elastomeric seal joints and smooth inner walls.
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for nonpressure drainage of sewage and surface water. Pipe and fittings produced to this specification should be installed in accordance with Practice D2321.
Note 1--Industrial waste disposal lines should be installed only with the specific approval of the governing code authority since temperatures in excess of 140oF (60oC) and chemicals not commonly found in drains and sewers may be encountered.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are provided for information purposes only.
1.4 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability or regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Jan-2001
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F679-00a - Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: F 679 – 00a An American National Standard
Standard Specification for
Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity
1
Sewer Pipe and Fittings
This standard is issued under the fixed designation F 679; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope D 2122 Test Method for Determining Dimensions of Ther-
4
moplastic Pipe and Fittings
1.1 This specification covers requirements and test methods
D 2152 Test Method for Degree of Fusion of Extruded
for materials, dimensions, workmanship, flattening resistance,
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
impact resistance, pipe stiffness, extrusion quality, joining
4
Acetone Immersion
system, and a form of marking for large diameters, 18 to 48 in.
D 2321 Practice for Underground Installation of Thermo-
(475 to 1200 mm) poly(vinyl chloride) (PVC) sewer pipe and
plastic Pipe for Sewers and Other Gravity-Flow Applica-
fittings with integral bell elastomeric seal joints and smooth
4
tions
inner walls.
D 2412 Test Method for Determination of External Loading
1.2 The requirements of this specification are intended to
4
Characteristics of Plastic Pipe by Parallel-Plate Loading
provide pipe and fittings suitable for nonpressure drainage of
D 2444 Test Method for Impact Resistance of Thermoplas-
sewage and surface water. Pipe and fittings produced to this
4
tic Pipe and Fittings by Means of a Tup (Falling Weight)
specification should be installed in accordance with Practice
D 2855 Practice for Making Solvent-Cemented Joints with
D 2321.
4
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
NOTE 1—Industrial waste disposal lines should be installed only with
D 3212 Specification for Joints for Drain and Sewer Plastic
the specific approval of the governing code authority since temperatures in
4
Pipes Using Flexible Elastomeric Seals
excess of 140°F (60°C) and chemicals not commonly found in drains and
F 402 Practice for Safe Handling of Solvent Cements,
sewers may be encountered.
Primers, and Cleaners Used for Joining Thermoplastic Pipe
1.3 The values stated in inch-pound units are to be regarded
4
and Fittings
as the standard. The values in parentheses are provided for 4
F 412 Terminology Relating to Plastic Piping Systems
information purposes only.
F 477 Specification for Elastomeric Seals (Gaskets) for
1.4 The following precautionary caveat pertains only to the 4
Joining Plastic Pipe
test method portion, Section 7, of this specification: This
2.2 Federal Standard:
standard does not purport to address all of the safety problems, 5
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
if any, associated with its use. It is the responsibility of the user
2.3 Military Standard:
of this standard to establish appropriate safety and health 5
MIL-STD-129 Marking for Shipment and Storage
practices and determine the applicability or regulatory limita-
tions prior to use.
3. Terminology
3.1 Definitions:
2. Referenced Documents
3.1.1 General—Definitions used in the specification are in
2.1 ASTM Standards:
accordance with Terminology F 412, unless otherwise indi-
D 618 Practice for Conditioning Plastics and Electrical
cated. The abbreviation for poly(vinyl chloride) pipe is PVC, in
2
Insulating Materials for Testing
accordance with Terminology D 1600.
D 1600 Terminology for Abbreviated Terms Relating to
2
Plastics
4. Materials
D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
4.1 Basic Materials—The pipe shall be made of PVC
Compounds and Chlorinated Poly(Vinyl Chloride)
plastic having a minimum cell classification of 12364C or
3
(CPVC) Compounds
12454C as defined in Specification D 1784. Homopolymer
PVC compounds must equal or exceed the requirements of the
1
This specification is under the jurisdiction of ASTM Committee F-17 on Plastic above listed minimum cell classification number.
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer
Pipe.
Current edition approved September 10, 2000. Published December 2000.
4
Originally published as F 679 – 80. Last previous edition F 679 – 95. Annual Book of ASTM Standards, Vol 08.04.
2 5
Annual Book of ASTM Standards, Vol 08.01. Available from Standardization Documents, Order Desk, Bldg. 4, Section D,
3
Annual Book of ASTM Standards, Vol 08.02. 700 Robbins Ave., Philadelphia, PA 19111-5094.
Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F 679
4.2 Rework Material—Clean rework material generated thickness of the equivalent size of pipe as specified in Table 1.
from the manufacturer’
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.