Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer and Drain Pipe Containing Recycled PVC Material

ABSTRACT
This specification covers the requirements and related test methods for materials, dimensions, workmanship, chemical resistance, and joint tightness of sewer and drain pipes made from either virgin or recycled poly(vinyl chloride) (PVC) compound. This specification also covers four-inch perforated pipes, but the joint tightness test is not applicable for this product. The pipes shall also be tested and thereby conform accordingly to the requirements for flattening resistance, extrusion quality, impact strength and resistance, stiffness, solvent cement, and perforations.
SCOPE
1.1 This specification covers pipe made from PVC compound that includes recycled PVC material. This specification covers requirements and test methods for materials, dimensions, workmanship, chemical resistance, and joint tightness of poly(vinyl chloride) (PVC) sewer and drain pipe. Four-inch perforated pipe is also covered; the joint tightness test is not applicable for this product. A form of marking to indicate compliance with this specification is also included.  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes, footnotes, and the Appendices (excluding those in tables and figures) shall not be considered as requirements of this standard.  
1.4 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification:  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Mar-2024
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1732-24 - Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer and Drain Pipe Containing Recycled PVC Material
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F1732-24 - Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer and Drain Pipe Containing Recycled PVC Material
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F1732 − 24
Standard Specification for
Poly(Vinyl Chloride) (PVC) Sewer and Drain Pipe Containing
1
Recycled PVC Material
This standard is issued under the fixed designation F1732; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This specification covers pipe made from PVC com-
D618 Practice for Conditioning Plastics for Testing
pound that includes recycled PVC material. This specification
D1600 Terminology for Abbreviated Terms Relating to Plas-
covers requirements and test methods for materials,
3
tics (Withdrawn 2024)
dimensions, workmanship, chemical resistance, and joint tight-
D1784 Classification System and Basis for Specification for
ness of poly(vinyl chloride) (PVC) sewer and drain pipe.
Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlo-
Four-inch perforated pipe is also covered; the joint tightness
rinated Poly(Vinyl Chloride) (CPVC) Compounds
test is not applicable for this product. A form of marking to
D2122 Test Method for Determining Dimensions of Ther-
indicate compliance with this specification is also included.
moplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded
1.2 The values stated in inch-pound units are to be regarded
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
as standard. The values given in parentheses are mathematical
Acetone Immersion
conversions to SI units that are provided for information only
D2321 Practice for Underground Installation of Thermoplas-
and are not considered standard.
tic Pipe for Sewers and Other Gravity-Flow Applications
1.3 The text of this standard references notes and footnotes
D2412 Test Method for Determination of External Loading
which provide explanatory material. These notes, footnotes,
Characteristics of Plastic Pipe by Parallel-Plate Loading
and the Appendices (excluding those in tables and figures) shall
D2444 Practice for Determination of the Impact Resistance
not be considered as requirements of this standard.
of Thermoplastic Pipe and Fittings by Means of a Tup
(Falling Weight)
1.4 The following precautionary caveat pertains only to the
D2564 Specification for Solvent Cements for Poly(Vinyl
test methods portion, Section 7, of this specification: This
Chloride) (PVC) Plastic Piping Systems
standard does not purport to address all of the safety concerns,
D2729 Specification for Poly(Vinyl Chloride) (PVC) Sewer
if any, associated with its use. It is the responsibility of the user
Pipe and Fittings
of this standard to establish appropriate safety, health, and
D3034 Specification for Type PSM Poly(Vinyl Chloride)
environmental practices and determine the applicability of
(PVC) Sewer Pipe and Fittings
regulatory limitations prior to use.
F412 Terminology Relating to Plastic Piping Systems
1.5 This international standard was developed in accor-
2.2 Federal Standard:
4
dance with internationally recognized principles on standard-
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
ization established in the Decision on Principles for the
2.3 Military Standard:
4
Development of International Standards, Guides and Recom-
MIL-STD-129 Marking for Shipment and Storage
mendations issued by the World Trade Organization Technical
3. Terminology
Barriers to Trade (TBT) Committee.
3.1 Definitions—Definitions used are in accordance with
Terminology F412, and abbreviations are in accordance with
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic the ASTM website.
3
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer. The last approved version of this historical standard is referenced on
Current edition approved April 1, 2024. Published May 2024. Originally www.astm.org.
4
approved as PS 1 in 1994. Last previous edition approved in 2012 as Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,
F1732–12(2018). DOI: 10.1520/F1732-24. Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ------
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F1732 − 12 (Reapproved 2018) F1732 − 24
Standard Specification for
Poly(Vinyl Chloride) (PVC) Sewer and Drain Pipe Containing
1
Recycled PVC Material
This standard is issued under the fixed designation F1732; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification covers pipe made from PVC compound that includes recycled PVC material. This specification covers
requirements and test methods for materials, dimensions, workmanship, chemical resistance, and joint tightness of poly(vinyl
chloride) (PVC) sewer and drain pipe. Four-inch perforated pipe is also covered; the joint tightness test is not applicable for this
product. A form of marking to indicate compliance with this specification is also included.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes, footnotes, and the
Appendices (excluding those in tables and figures) shall not be considered as requirements of this standard.
1.4 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory
limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
3
D1600 Terminology for Abbreviated Terms Relating to Plastics (Withdrawn 2024)
D1784 Classification System and Basis for Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated
Poly(Vinyl Chloride) (CPVC) Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone
Immersion
D2321 Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved Aug. 1, 2018April 1, 2024. Published November 2018May 2024. Originally approved as PS 1 in 1994. Last previous edition approved in 2012
as F1732–12. DOI: 10.1520/F1732-12R18.F1732–12(2018). DOI: 10.1520/F1732-24.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
The last approved version of this historical standard is referenced on www.astm.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1732 − 24
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 Practice for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling
Weight)
D2564 Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems
D2729 Specification for Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings
D3034 Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings
F412 Terminology Relating to Plastic Piping Systems
2.2 Federal Standard:
4
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
2.3 Military Standard:
4
MIL-STD-129 Marking for Shipment and Storage
3. Terminology
3.1 Definitions—Defini
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.