Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe (Metric)

SCOPE
1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts.
1.2 This specification is the metric counterpart of Specification C655. Note 1-Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

General Information

Status
Historical
Publication Date
09-Jun-2000
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C655M-00 - Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe (Metric)
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 655M – 00
METRIC
Standard Specification for
Reinforced Concrete D-Load Culvert, Storm Drain, and
1
Sewer Pipe [Metric]
This standard is issued under the fixed designation C 655M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
3
1. Scope and Sawed Beams of Concrete
4
C 150 Specification for Portland Cement
1.1 This specification covers reinforced concrete pipe de-
C 497M Test Methods for Concrete Pipe, Manhole Sec-
signed for specific D-loads and intended to be used for the
5
tions, or Tile [Metric]
conveyance of sewage, industrial wastes, and storm water and
4
C 595 Specification for Blended Hydraulic Cements
for the construction of culverts.
C 618 Specification for Fly Ash and Raw or Calcined
1.2 This specification is the metric counterpart of Specifi-
Natural Pozzolan for Use as a Mineral Admixture in
cation C 655.
3
Portland Cement Concrete
NOTE 1—Experience has shown that the successful performance of this
C 822 Terminology Relating to Concrete Pipe and Related
product depends upon the proper selection of the pipe strength, the type of
5
Products
bedding and backfill, the care that the installation conforms to the
C 1116 Specification for Fiber-Reinforced Concrete and
construction specifications, and provision for adequate inspection at the
3
Shotcrete
construction site. This specification does not include requirements for
6
bedding, backfill, the relationship between field load conditions and the E 105 Practice for Probability Sampling of Materials
strength designation of pipe, or durability under unusual environmental
3. Terminology
conditions. These requirements should be included in the project specifi-
cation.
3.1 Definitions—For definitions of terms relating to con-
crete pipe, see Terminology C 822.
2. Referenced Documents
2.1 ASTM Standards:
4. Basis of Acceptance
A 82 Specification for Steel Wire, Plain, for Concrete Re-
4.1 The acceptability of the pipe design shall be determined
2
inforcement
in accordance with Section 9. After the pipe design has been
A 185 Specification for Steel Welded Wire Fabric, Plain, for
accepted, or if the pipe design has been accepted previously in
2
Concrete Reinforcement
accordance with Section 9, the owner may select and have
A 496 Specification for Steel Wire, Deformed, for Concrete
applied the basis of acceptance described in either 4.1.1 or
2
Reinforcement
4.1.2. Unless designated by the owner at the time of, or before
A 497 Specification for Steel Welded Wire Fabric, De-
placing an order, either basis of acceptance shall be permitted.
2
formed, for Concrete Reinforcement
4.1.1 Acceptance on the Basis of Pipe Load and Material
A 615/A 615M Specification for Deformed and Plain
Tests and Inspection of Manufactured Pipe for Defects
2
Billet-Steel Bars for Concrete Reinforcement [Metric]
—Determine in accordance with Sections 5, 6, 8, and 10.
C 31 Practice for Making and Curing Concrete Test Speci-
3
NOTE 2—It is necessary that samples be selected at random. For
mens in the Field
3 guidance see Practice E 105.
C 33 Specification for Concrete Aggregates
C 39 Test Method for Compressive Strength of Cylindrical 4.1.2 Acceptance on the Basis of Concrete Compression and
3
Materials Tests and Inspection of Manufactured Pipe for
Concrete Specimens
C 42 Test Method for Obtaining and Testing Drilled Cores Defects—Determine in accordance with Sections 5, 6, 8, and
11.
4.2 Age for Acceptance—Pipe shall be considered ready for
1
This specification is under the jurisdiction of ASTM Committee C13 on
acceptance when they conform to the requirements.
Concrete Pipe and is the direct responsibility of Subcommittee C13.07 on
Acceptance Specifications and Precast Concrete Box Sections.
Current edition approved June 10, 2000. Published September 2000. Originally
4
published as C 655M–80. Last previous edition C 655M–95a. Annual Book of ASTM Standards, Vol 04.01.
2 5
Annual Book of ASTM Standards, Vol 01.04. Annual Book of ASTM Standards, Vol 04.05.
3 6
Annual Book of ASTM Standards, Vol 04.02. Annual Book of ASTM Standards, Vol 14.02.
Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
C 655M
5. Design and Manufacturing Data and shall be added to the mix in a proportion not less than 280
3
kg/m unless mix designs with a lower cementitious
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.