Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)

ABSTRACT
This specification covers reinforced concrete culvert, storm drain, and sewer pipe. The pipe manufactured with this specification shall be of five classes: Class I, Class II, Class III, Class IV, and Class V. The strength requirements for each class are specified. The reinforced concrete shall consists of: cementitious materials, mineral aggregates, and water. Cementitious materials are the following: cement, ground granulated blast-furnace slag, fly ash, and allowable combinations of cementitious materials. Other materials include: admixtures and blends, steel reinforcement, and synthetic fibers. Design tables and modified of special designs are given. Reinforcements are the following: circumferential reinforcement, longitudinal reinforcement, and joint reinforcement for rubber and non-rubber gasket joints. The physical properties shall conform to the required test for external load crushing strength. The following concrete tests shall be done: compression testing of cylinders, compression testing of cores, absorption test, and equipment test.
SCOPE
1.1 This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts.  
1.2 This specification is the SI companion to Specification C76; therefore, no inch-pound equivalents are presented in this specification. Reinforced concrete pipe that conform to the requirements of C76 are acceptable under this Specification C76M unless prohibited by the Owner.
Note 1: This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, controlled manufacture in the plant, and care and installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.
Note 2: Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (ASTM Designation C655M).  
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Aug-2022
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C76M-22a - Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C76M-22a - Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:C76M −22a
Standard Specification for
Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe
1
(Metric)
This standard is issued under the fixed designation C76M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope* Steel Bars for Concrete Reinforcement
A706/A706M Specification for Deformed and Plain Low-
1.1 This specification covers reinforced concrete pipe in-
Alloy Steel Bars for Concrete Reinforcement
tended to be used for the conveyance of sewage, industrial
A1064/A1064M Specification for Carbon-Steel Wire and
wastes, and storm water, and for the construction of culverts.
Welded Wire Reinforcement, Plain and Deformed, for
1.2 This specification is the SI companion to Specification
Concrete
C76; therefore, no inch-pound equivalents are presented in this
C33/C33M Specification for Concrete Aggregates
specification. Reinforced concrete pipe that conform to the
C150/C150M Specification for Portland Cement
requirements of C76 are acceptable under this Specification
C260/C260M Specification for Air-Entraining Admixtures
C76M unless prohibited by the Owner.
for Concrete
NOTE 1—This specification is a manufacturing and purchase specifica-
C309 Specification for Liquid Membrane-Forming Com-
tion only, and does not include requirements for bedding, backfill, or the
pounds for Curing Concrete
relationship between field load condition and the strength classification of
C443M Specification for Joints for Concrete Pipe and
pipe. However, experience has shown that the successful performance of
Manholes, Using Rubber Gaskets (Metric)
this product depends upon the proper selection of the class of pipe, type
C494/C494M Specification for Chemical Admixtures for
of bedding and backfill, controlled manufacture in the plant, and care and
installation conforms to the construction specifications. The owner of the
Concrete
reinforced concrete pipe specified herein is cautioned that he must
C497M Test Methods for Concrete Pipe, Concrete Box
correlate the field requirements with the class of pipe specified and
Sections, Manhole Sections, or Tile (Metric)
provide inspection at the construction site.
C595/C595M Specification for Blended Hydraulic Cements
NOTE 2—Attention is called to the specification for reinforced concrete
D-load culvert, storm drain, and sewer pipe (ASTM Designation C655M).
C618 Specification for Coal Fly Ash and Raw or Calcined
Natural Pozzolan for Use in Concrete
1.3 This international standard was developed in accor-
dance with internationally recognized principles on standard- C655M Specification for Reinforced Concrete D-Load
Culvert, Storm Drain, and Sewer Pipe (Metric)
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom- C822 Terminology Relating to Concrete Pipe and Related
Products
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee. C989/C989M Specification for Slag Cement for Use in
Concrete and Mortars
2. Referenced Documents
C990M Specification for Joints for Concrete Pipe,
2
Manholes, and Precast Box Sections Using Preformed
2.1 ASTM Standards:
Flexible Joint Sealants (Metric)
A36/A36M Specification for Carbon Structural Steel
C1017/C1017M Specification for Chemical Admixtures for
A615/A615M SpecificationforDeformedandPlainCarbon-
3
Use in Producing Flowing Concrete (Withdrawn 2022)
C1116/C1116M Specification for Fiber-Reinforced Concrete
1
C1602/C1602M Specification for Mixing Water Used in the
This specification is under the jurisdiction of ASTM Committee C13 on
Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on
Production of Hydraulic Cement Concrete
Reinforced Sewer and Culvert Pipe.
C1628 Specification for Joints for Concrete Gravity Flow
Current edition approved Sept. 1, 2022. Published September 2022. Originally
Sewer Pipe, Using Rubber Gaskets
approved in 1980. Last previous edition approved in 2022 as C76M - 22. DOI:
10.1520/C0076M-22A.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on The last approved version of this historical standard is referenced on
the ASTM website. www.astm.org.
*A Summary of Changes section appears at the end of this standard
Copyri
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C76M − 22 C76M − 22a
Standard Specification for
Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe
1
(Metric)
This standard is issued under the fixed designation C76M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope*
1.1 This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and
storm water, and for the construction of culverts.
1.2 This specification is the SI companion to Specification C76; therefore, no inch-pound equivalents are presented in this
specification. Reinforced concrete pipe that conform to the requirements of C76 are acceptable under this Specification C76M
unless prohibited by the Owner.
NOTE 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship
between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product
depends upon the proper selection of the class of pipe, type of bedding and backfill, controlled manufacture in the plant, and care and installation conforms
to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements
with the class of pipe specified and provide inspection at the construction site.
NOTE 2—Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (ASTM Designation C655M).
1.3 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
A36/A36M Specification for Carbon Structural Steel
A615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement
A706/A706M Specification for Deformed and Plain Low-Alloy Steel Bars for Concrete Reinforcement
A1064/A1064M Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete
C33/C33M Specification for Concrete Aggregates
C150/C150M Specification for Portland Cement
C260/C260M Specification for Air-Entraining Admixtures for Concrete
C309 Specification for Liquid Membrane-Forming Compounds for Curing Concrete
1
This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on Reinforced Sewer
and Culvert Pipe.
Current edition approved March 1, 2022Sept. 1, 2022. Published March 2022September 2022. Originally approved in 1980. Last previous edition approved in 20202022
as C76M - 20.C76M - 22. DOI: 10.1520/C0076M-22.10.1520/C0076M-22A.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C76M − 22a
C443M Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets (Metric)
C494/C494M Specification for Chemical Admixtures for Concrete
C497M Test Methods for Concrete Pipe, Concrete Box Sections, Manhole Sections, or Tile (Metric)
C595/C595M Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C655M Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe (Metric)
C822 Terminology Relating to Concrete Pipe and Related Products
C989/C989M Specification for Slag Cement for Use in Concrete and Mortars
C990M Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants
(Metric)
3
C1017/C1017M Specification for Chemical Admixtures for Use in Producing
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.