ASTM F1678-96
(Test Method)Standard Test Method for Using a Portable Articulated Strut Slip Tester (PAST) (Withdrawn 2005)
Standard Test Method for Using a Portable Articulated Strut Slip Tester (PAST) (Withdrawn 2005)
SCOPE
1.1 This test method covers the operational procedures for using a portable articulated strut slip tester (PAST) for determining the slip resistance of footwear sole, heel, or related materials (test feet) against planar walkway surfaces or walkway surrogates (test surfaces) in either the laboratory or field under dry conditions. This test method does not address all methodological issues (for example, test surface and test foot material selection and preparation, experimental design, or report preparation).
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
WITHDRAWN RATIONALE
This test method covers the operational procedures for using a portable articulated strut slip tester (PAST) for determining the slip resistance of footwear sole, heel, or related materials (test feet) against planar walkway surfaces or walkway surrogates (test surfaces) in either the laboratory or field under dry conditions. This test method does not address all methodological issues (for example, test surface and test foot material selection and preparation, experimental design, or report preparation).
Formerly under the jurisdiction of Committee F13 on Pedestrian/Walkway Safety and Footwear, this test method was withdrawn in June 2005 in accordance with section 10.5.3.1 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.
General Information
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation:F1678–96
Standard Test Method for
Using a Portable Articulated Strut Slip Tester (PAST)
This standard is issued under the fixed designation F 1678; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 4.2 The measurement made by this apparatus relates to slip
resistance and the static coefficient of friction. Other factors
1.1 This test method covers the operational procedures for
can affect slip resistance.When this test method is used in field
using a portable articulated strut slip tester (PAST) for deter-
tests, relevant factors shall be described.
mining the slip resistance of footwear sole, heel, or related
materials (test feet) against planar walkway surfaces or walk-
5. Apparatus
way surrogates (test surfaces) in either the laboratory or field
5.1 Portable Articulated Strut Tribometer—See Fig. 1.
under dry conditions. This test method does not address all
5.2 Main Components:
methodological issues (for example, test surface and test foot
5.2.1 Frame, aluminum, U-shaped (a).
material selection and preparation, experimental design, or
5.2.2 Carriage Rails, two, steel, horizontal (b).
report preparation).
5.2.3 Carriage, aluminum (c).
1.2 The values stated in inch-pound units are to be regarded
5.2.4 Weight, cast steel (d).
as the standard. The values given in parentheses are for
5.2.5 Articulated Strut, aluminum, ladder shaped (e).
information only.
5.2.6 Trigger, steel (f).
1.3 This standard does not purport to address all of the
5.2.7 Trigger Adjustment Knob and Adjustment Lock
safety concerns, if any, associated with its use. It is the
Knob (g).
responsibility of the user of this standard to establish appro-
5.2.8 Trigger Stop (h).
priate safety and health practices and determine the applica-
5.2.9 Measuring Rod, steel, cylindrical, graduated (i).
bility of regulatory limitations prior to use.
5.2.10 Measuring Rod Index Mark, brass (j).
2. Referenced Documents 5.2.11 Test Foot Holder, magnetic (k).
5.2.12 Spring Collars (l).
2.1 ASTM Standards:
5.2.13 Spacer, 0.5 in. (13 mm) (not shown).
F 1646 Terminology Relating to Safety and Traction for
Footwear
6. Test Foot and Test Surface
3. Terminology 6.1 Test Foot:
6.1.1 The test foot is prepared by fastening a sample,
3.1 Definitions—For definitions of terms, refer to Terminol-
2 2
typically 3 by 3 in. (76.2 by 76.2 mm ), of the test foot
ogy F 1646.
material, appropriate side exposed, using a suitable adhesive,
4. Significance and Use such as double-stick tape.
6.1.2 The test foot is placed on the test foot holder, where it
4.1 The PAST is a tribometer designed to determine the
is held in place by magnetic attraction.
slip resistance of footwear materials, walkway surfaces, or
6.2 Test Surface—The floor surface specimens shall not be
surrogates under field or laboratory conditions so that their
less than 4 by 4 in. (10.16 by 10.16 cm) and should be
slip-resistant qualities may be evaluated.
surrounded by enough material of similar thickness or placed
in a suitable fixture so that the tribometer feet will be at the
This test method is under the jurisdiction ofASTM Committee F-13 on Safety
same elevation as the top of the specimen. The test foot
and Traction for Footwear and is the direct responsibility of Subcommittee F13.10
material shall fit within the area of the test surface.
on Traction.
Current edition approved February 10, 1996. Published May 1996.
Annual Book of ASTM Standards, Vol 15.07.
The portable articulated strut slip tester (PAST) was developed by Dr. Robert
4 2 2
BrungraberofBucknellUniversity,Lewisburg,PA.ThePASTiscoveredbyapatent The most convenient test foot material shape is a 3 in. (76.2 mm ), but if a
held by Slip-Test and is available from P.O. Box 387, Spring Lake, NJ 07762. It has differentshapeisdesireditmustbesymmetricalwithrespecttothecenterlineinthe
been found suitable for this use. Interested parties are invited to submit information directionoftestingandhavesomematerialatthefrontandrearedgesofthetestfoot
regarding the identification of acceptable alternatives to this patented item to the clip. This allows testing at various contact pressures.
Committee on Standards, ASTM Headquarters, 100 Barr Harbor Drive, West Floor surface materials of sizes smaller than 4 by 4 in. (100 by 100 mm) may
Conshohocken, PA 19428-2959. Your comments will receive careful consideration be combined in a matrix to create a surface area at least 4 by 4 in. (100 by 100 mm)
at a meeting of the responsible technical committee, which you may attend. in size.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
F1678–96
9.2 Using a clean cloth or paper napkin, thoroughly wipe all
parts of the vertical and horizontal carriage rails.
9.3 Select a test foot having a suitable facing material, and
attach it to the bottom of the test foot holder, making certain
that the vertical extension extends up through the hole in the
base plate and lies behind the trigger. Also be certain that the
foot is pushed back with respect to the test foot holder as far as
it will go, so that the vertical extension is thoroughly engaged
in the single notch at the front of the test foot holder.
9.4 Remove the measuring rod from the frame clips, and
wipe it thoroughly with a clean cloth or paper napkin. Insert its
magnetic end through the index mark tube (j), pushing the rod
back until the magnet engages the head of the adjustable
carbon steel bolt attached to the carriage. While inserting the
rod, be certain that the trigger assembly is released thoroughly
by pushing the test foot as far toward the rear of the tester as
it will go. It may be necessary to back off the trigger
adjustment knob if the rod fails to slide in easily. This is
accomplished by first releasing the trigger locknut.
not shown = spacer, 0.5 in. (13 mm)
9.5 Adjust the trigger by first putting the tester on a level
a =frame, aluminum, U-shaped
surface, with the test foot to the rear of its possible travel and
b =carriage rails, two, steel, horizontal
c =carriage, aluminum
with the carriage fully forward. Then adjust the trigger so that
d =weight, cast steel
the 0.05-in. (1.3-mm) thick spacer, supplied with the tester, can
e =articulated strut, aluminum, ladder shaped
be placed easily between the trigger and the vertical extension
f =trigger, steel
g =trigger adjustment knob and adjustment lock knob
on the front of the test foot.
h =trigger stop
9.6 Set the trigger
...