Standard Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains

ABSTRACT
This specification covers single-cell precast conventionally reinforced concrete three-sided structures intended to be used for the construction of culverts and for the conveyance of storm water. Precast reinforced concrete three-sided structures manufactured in accordance with this specification shall be designated by span, rise, and design earth cover. The reinforced concrete shall consist of cementitious materials, mineral aggregates and water, in which steel has been embedded in such a manner that the steel and concrete act together. The three-sided section's dimensions and reinforcement details shall be as required by design. Splices in the circumferential reinforcement shall be made by lapping. The precast reinforced concrete three-sided structures shall be produced with tongue and groove ends, flat butt ends or key-way ends. The aggregates shall be sized, graded, proportioned, and mixed with such proportions of cementitious materials and water as will produce a homogeneous concrete mixture of such quality that each section will conform to the test and design requirements. The three-sided sections shall be cured for a sufficient length of time so that the concrete will develop the required compressive strength. The forms used in manufacture shall be sufficiently rigid and accurate to maintain the three-sided section dimensions within the permissible variations. Handling devices or holes shall be permitted in each three-sided section for the purpose of handling and laying. Cylinders and cores shall be obtained and tested for compressive strength to meet the requirements prescribed.
SCOPE
1.1 This specification covers single-cell precast conventionally reinforced concrete three-sided structures intended to be used for the construction of culverts and for the conveyance of storm water.  
1.2 A complete metric companion to Specification C1504 has been developed—C1504M; therefore, no metric equivalents are presented in this specification.Note 1—This specification is primarily a manufacturing and purchasing specification. The successful performance of this product depends upon the proper selection of the geometric section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete three-sided structure specified herein is cautioned that proper correlation of the loading conditions and the field requirements with the geometric section specified and provisions for inspection at the construction site are required.  
1.3 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.

General Information

Status
Historical
Publication Date
30-Jun-2013
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1504-13a - Standard Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C1504-13a - Standard Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1504 −13a
StandardSpecification for
Manufacture of Precast Reinforced Concrete Three-Sided
1
Structures for Culverts and Storm Drains
This standard is issued under the fixed designation C1504; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope C39/C39M Test Method for Compressive Strength of Cylin-
drical Concrete Specimens
1.1 This specification covers single-cell precast convention-
C150 Specification for Portland Cement
ally reinforced concrete three-sided structures intended to be
C260/C260M Specification for Air-Entraining Admixtures
used for the construction of culverts and for the conveyance of
for Concrete
storm water.
C309 Specification for Liquid Membrane-Forming Com-
1.2 A complete metric companion to Specification C1504
pounds for Curing Concrete
has been developed—C1504M; therefore, no metric equiva-
C494/C494M Specification for Chemical Admixtures for
lents are presented in this specification.
Concrete
C497 Test Methods for Concrete Pipe, Manhole Sections, or
NOTE 1—This specification is primarily a manufacturing and purchas-
ing specification. The successful performance of this product depends
Tile
upon the proper selection of the geometric section, bedding, backfill, and
C595 Specification for Blended Hydraulic Cements
care that the installation conforms to the construction specifications. The
C618 Specification for Coal Fly Ash and Raw or Calcined
purchaser of the precast reinforced concrete three-sided structure specified
Natural Pozzolan for Use in Concrete
herein is cautioned that proper correlation of the loading conditions and
C822 Terminology Relating to Concrete Pipe and Related
the field requirements with the geometric section specified and provisions
for inspection at the construction site are required.
Products
C989 Specification for Slag Cement for Use in Concrete and
1.3 The values stated in inch-pound units are to be regarded
Mortars
as standard. No other units of measurement are included in this
C1116 Specification for Fiber-Reinforced Concrete and
standard.
Shotcrete
2.2 AASHTO Standard:
2. Referenced Documents
3
AASHTO LRFD Bridge Design Specification
2
2.1 ASTM Standards:
2.3 ACI Standard:
A1064/A1064M Specification for Carbon-Steel Wire and
ACI 318 Building Code Requirements for Structural Con-
Welded Wire Reinforcement, Plain and Deformed, for
4
crete and Commentary
Concrete
A615/A615M SpecificationforDeformedandPlainCarbon-
3. Terminology
Steel Bars for Concrete Reinforcement
3.1 Definitions—For definitions of terms relating to geomet-
A706/A706M Specification for Low-Alloy Steel Deformed
ric sections, see Terminology C822.
and Plain Bars for Concrete Reinforcement
C31/C31M Practice for Making and Curing Concrete Test
4. Types
Specimens in the Field
4.1 Precast reinforced concrete three-sided structures manu-
C33 Specification for Concrete Aggregates
factured in accordance with this specification shall be desig-
nated by span, rise, and design earth cover.
1
This specification is under the jurisdiction of ASTM Committee C13 on 5. Basis of Acceptance
Concrete Pipe and is the direct responsibility of Subcommittee C13.07 on
5.1 Acceptability of the three-sided sections produced in
Acceptance Specifications and Precast Concrete Box Sections.
Current edition approved July 1, 2013. Published July 2013. Originally approved accordance with Section 7 shall be determined by the results of
in 2001. Last previous edition approved in 2013 as C1504 – 13. DOI: 10.1520/
C1504-13A.
2 3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or American Association of State Highway and Transportation Officials
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM (AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001.
4
Standards volume information, refer to the standard’s Document Summary page on Available fromAmerican Concrete Institute (ACI), P.O. Box 9094, Farmington
the ASTM website. Hills, MI 48333-9094, http://www.concrete.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1504 − 13a
the concrete compressive strength tests described in Section 6.6 Synthetic Fibers—Collated fibrillated virgin polypropyl-
10, by the material requirements described in Section 6, and by ene fibers may be used, at the manufacturer’s option, in
inspection of the finished three-sided sections.
three-sided structures as a nonstructural manufacturing mate-
rial. Only type III synthetic fibers designed and manufactured
5.2 Three-sided sect
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1504 − 13 C1504 − 13a
Standard Specification for
Manufacture of Precast Reinforced Concrete Three-Sided
1
Structures for Culverts and Storm Drains
This standard is issued under the fixed designation C1504; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers single-cell precast conventionally reinforced concrete three-sided structures intended to be used
for the construction of culverts and for the conveyance of storm water.
1.2 A complete metric companion to Specification C1504 has been developed—C1504M; therefore, no metric equivalents are
presented in this specification.
NOTE 1—This specification is primarily a manufacturing and purchasing specification. The successful performance of this product depends upon the
proper selection of the geometric section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of
the precast reinforced concrete three-sided structure specified herein is cautioned that he must properly correlate proper correlation of the loading
conditions and the field requirements with the geometric section specified and provideprovisions for inspection at the construction site.site are required.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformance with the as standard. No other units of measurement are included in this standard.
2. Referenced Documents
2
2.1 ASTM Standards:
A82/A82MA1064/A1064M Specification for Steel Wire, Plain, for Concrete ReinforcementCarbon-Steel Wire and Welded Wire
Reinforcement, Plain and Deformed, for Concrete
A185/A185M Specification for Steel Welded Wire Reinforcement, Plain, for Concrete
A496/A496M Specification for Steel Wire, Deformed, for Concrete Reinforcement
A497/A497M Specification for Steel Welded Wire Reinforcement, Deformed, for Concrete
A615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement
3
A616/A616M Specification for Rail-Steel Deformed and Plain Bars for Concrete Reinforcement (Withdrawn 1999)
3
A617/A617M Specification for Axle-Steel Deformed and Plain Bars for Concrete Reinforcement (Withdrawn 1999)
A706/A706M Specification for Low-Alloy Steel Deformed and Plain Bars for Concrete Reinforcement
C31/C31M Practice for Making and Curing Concrete Test Specimens in the Field
C33 Specification for Concrete Aggregates
C39/C39M Test Method for Compressive Strength of Cylindrical Concrete Specimens
C150 Specification for Portland Cement
C260/C260M Specification for Air-Entraining Admixtures for Concrete
C309 Specification for Liquid Membrane-Forming Compounds for Curing Concrete
C494/C494M Specification for Chemical Admixtures for Concrete
C497 Test Methods for Concrete Pipe, Manhole Sections, or Tile
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C822 Terminology Relating to Concrete Pipe and Related Products
C989 Specification for Slag Cement for Use in Concrete and Mortars
1
This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.07 on Acceptance
Specifications and Precast Concrete Box Sections.
Current edition approved Feb. 15, 2013July 1, 2013. Published March 2013July 2013. Originally approved in 2001. Last previous edition approved in 20102013 as
C1504 – 04 (2010).C1504 – 13. DOI: 10.1520/C1504-13.10.1520/C1504-13A.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1504 − 13a
C1116 Specification for Fiber-Reinforced Concrete and Shotcrete
2.2 AASHTO Standard:
3
Standard Specifications for Highway BridgesAASHTO LRFD Bridge Design Specification
2.3 ACI Standard:
4
ACI 318 Buil
...

Questions, Comments and Discussion