Standard Specification for Manufacture of Reinforced Concrete Sewer, Storm Drain, and Culvert Pipe for Direct Design (Metric)

ABSTRACT
This specification covers the manufacture and acceptance of reinforced concrete sewer, storm drain, and culvert pipe designed to conform to the owner's design requirements and to equivalent design specification. The reinforced concrete shall consist of cementitious materials; mineral aggregates; admixtures, if used; and water. The cementitious material shall be composed of cement, ground graduated blast-furnace; fly ash; allowable combinations of cementitious materials; a combination of Portland cement and ground granulated blast-furnace slag; a combination of Portland cement and fly ash; or a combination of Portland cement, ground granulated blast-furnace slag, and fly ash; aggregates; admixtures; air-entraining admixture; chemical admixtures; and steel reinforcement. The joints shall be designed and the ends of the concrete pipe sections shall be formed so that the sections can be laid together to make a continuous line of pipe. The pipe shall conform to the requirements of circumferential reinforcement, longitudinal reinforcement, and joint reinforcement. The specimen shall conform to the specified physical requirements after undertaking the following test procedures: concrete compressive strength testing; acceptance by cylinder tests; and acceptance by core tests.
SCOPE
1.1 This specification covers the manufacture and acceptance of precast concrete pipe designed to conform to the owner's design requirements and to the ASCE 15 or an equivalent design specification.
Note 1: The section on evaluation of core test results (14.3.3) and the Appendix are currently being reballoted.  
1.2 This specification is the SI companion to Specification C1417.

General Information

Status
Historical
Publication Date
31-Jan-2014
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1417M-14e1 - Standard Specification for Manufacture of Reinforced Concrete Sewer, Storm Drain, and Culvert Pipe for Direct Design (Metric)
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C1417M-14e1 - Standard Specification for Manufacture of Reinforced Concrete Sewer, Storm Drain, and Culvert Pipe for Direct Design (Metric)
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation:C1417M −14
StandardSpecification for
Manufacture of Reinforced Concrete Sewer, Storm Drain,
1
and Culvert Pipe for Direct Design (Metric)
This standard is issued under the fixed designation C1417M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—Editorially revised title of 6.4 in March 2015.
1. Scope C618 Specification for Coal Fly Ash and Raw or Calcined
Natural Pozzolan for Use in Concrete
1.1 This specification covers the manufacture and accep-
C655 Specification for Reinforced Concrete D-Load
tance of precast concrete pipe designed to conform to the
Culvert, Storm Drain, and Sewer Pipe
owner’s design requirements and to the ASCE 15 or an
C822 Terminology Relating to Concrete Pipe and Related
equivalent design specification.
Products
NOTE 1—The section on evaluation of core test results (14.3.3) and the
C989 Specification for Slag Cement for Use in Concrete and
Appendix are currently being reballoted.
Mortars
1.2 This specification is the SI companion to Specification
C1017/C1017M Specification for Chemical Admixtures for
C1417.
Use in Producing Flowing Concrete
C1602/C1602M Specification for Mixing Water Used in the
2. Referenced Documents
Production of Hydraulic Cement Concrete
2
2.1 ASTM Standards:
2.2 Other Standards:
A615/A615M SpecificationforDeformedandPlainCarbon-
ASCE 15 Standard Practice for the Direct Design of Buried
Steel Bars for Concrete Reinforcement
Precast Reinforced Concrete Pipe Using Standard Instal-
A706/A706M Specification for Deformed and Plain Low-
3
Alloy Steel Bars for Concrete Reinforcement lations (SIDD)
A1064/A1064M Specification for Carbon-Steel Wire and ACI 318 Building Code Requirements for Reinforced Con-
4
Welded Wire Reinforcement, Plain and Deformed, for
crete
Concrete
C33 Specification for Concrete Aggregates
3. Terminology
C76 Specification for Reinforced Concrete Culvert, Storm
3.1 Definitions:
Drain, and Sewer Pipe
3.1.1 For definitions of terms relating to concrete pipe, see
C150 Specification for Portland Cement
Terminology C822.
C260/C260M Specification for Air-Entraining Admixtures
for Concrete
3.1.2 group of pipe sections—each day’s production run of
C494/C494M Specification for Chemical Admixtures for
pipesectionsofasingleconcretestrengthforaspecificproject.
Concrete
3.1.3 lot of pipe sections—total of the number of groups of
C497 Test Methods for Concrete Pipe, Manhole Sections, or
pipe sections of a single concrete strength produced for a
Tile
specific project.
C595 Specification for Blended Hydraulic Cements
3.1.4 running average—average concrete compressive
strength of all groups of pipe sections of a single concrete
1
This specification is under the jurisdiction of ASTM Committee C13 on
strength produced for a specific project, generally determined
Concrete Pipe and is the direct responsibility of Subcommittee C13.05 on Special
as each group is tested.
Projects.
Current edition approved Feb. 1, 2014. Published February 2014. Originally
approved in 1998. Last previous edition approved in 2013 as C1417M – 13a. DOI:
10.1520/C1417M-14E01.
2 3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available from American Society of Civil Engineers (ASCE), 1801 Alexander
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Bell Dr., Reston, VA 20191, http://www.asce.org.
4
Standards volume information, refer to the standard’s Document Summary page on Available fromAmerican Concrete Institute (ACI), P.O. Box 9094, Farmington
the ASTM website. Hills, MI 48333-9094, http://www.aci-int.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
´1
C1417M−14
4. Basis of Acceptance of Design 6.2.2 Slag Cement—Slag cement shall conform to the re-
quirements of Grade 100 or 120 of Specification C989.
4.1 Manufacturing Design Data—The manufacturer shall
6.2.3 Fly Ash—Fly ash shall conform to the requirements of
submit the following manufacturing design data for the con-
Specification C618, Class F or Class C.
crete pipe to the owner for approval.
6.2.4 Allowable Combinations of Cementitious Materials—
4.1.1 Pipe wall thickness.
Thecombinationofcementitiousmaterialsusedintheconcrete
4.1.2 Concrete strength.
shall be one of the following:
4.1.3 Reinforcement:
6.2.4.1 Portland cement only.
4.1.3.1 Specification,
6.2.4.2 Portland blast-furnace slag cement only.
4.1.3.2 Reinforcement Type 1, 2, or 3, where:
6.2.4.3 Portland-pozzolan cement only.
Type 1: Smooth wire or plain bars
Type 2: Welded smooth wire rein
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation: C1417M − 14 C1417M − 14
Standard Specification for
Manufacture of Reinforced Concrete Sewer, Storm Drain,
1
and Culvert Pipe for Direct Design (Metric)
This standard is issued under the fixed designation C1417M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—Editorially revised title of 6.4 in March 2015.
1. Scope
1.1 This specification covers the manufacture and acceptance of precast concrete pipe designed to conform to the owner’s
design requirements and to the ASCE 15 or an equivalent design specification.
NOTE 1—The section on evaluation of core test results (14.3.3) and the Appendix are currently being reballoted.
1.2 This specification is the SI companion to Specification C1417.
2. Referenced Documents
2
2.1 ASTM Standards:
A615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement
A706/A706M Specification for Deformed and Plain Low-Alloy Steel Bars for Concrete Reinforcement
A1064/A1064M Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete
C33 Specification for Concrete Aggregates
C76 Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe
C150 Specification for Portland Cement
C260/C260M Specification for Air-Entraining Admixtures for Concrete
C494/C494M Specification for Chemical Admixtures for Concrete
C497 Test Methods for Concrete Pipe, Manhole Sections, or Tile
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C655 Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe
C822 Terminology Relating to Concrete Pipe and Related Products
C989 Specification for Slag Cement for Use in Concrete and Mortars
C1017/C1017M Specification for Chemical Admixtures for Use in Producing Flowing Concrete
C1602/C1602M Specification for Mixing Water Used in the Production of Hydraulic Cement Concrete
2.2 Other Standards:
ASCE 15 Standard Practice for the Direct Design of Buried Precast Reinforced Concrete Pipe Using Standard Installations
3
(SIDD)
4
ACI 318 Building Code Requirements for Reinforced Concrete
3. Terminology
3.1 Definitions:
3.1.1 For definitions of terms relating to concrete pipe, see Terminology C822.
3.1.2 group of pipe sections—each day’s production run of pipe sections of a single concrete strength for a specific project.
1
This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.05 on Special Projects.
Current edition approved Feb. 1, 2014. Published February 2014. Originally approved in 1998. Last previous edition approved in 2013 as C1417M – 13a. DOI:
10.1520/C1417M-14.10.1520/C1417M-14E01.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from American Society of Civil Engineers (ASCE), 1801 Alexander Bell Dr., Reston, VA 20191, http://www.asce.org.
4
Available from American Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI 48333-9094, http://www.aci-int.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
´1
C1417M − 14
3.1.3 lot of pipe sections—total of the number of groups of pipe sections of a single concrete strength produced for a specific
project.
3.1.4 running average—average concrete compressive strength of all groups of pipe sections of a single concrete strength
produced for a specific project, generally determined as each group is tested.
4. Basis of Acceptance of Design
4.1 Manufacturing Design Data—The manufacturer shall submit the following manufacturing design data for the concrete pipe
to the owner for approval.
4.1.1 Pipe wall thickness.
4.1.2 Concrete strength.
4.1.3 Reinforcement:
4.1.3.1 Specification,
4.1.3.2 Reinforcement Type 1, 2, or 3, where:
Type 1: Smooth wire or plain bars
Type 2: Welded smooth wire reinforcement, 200 mm maximum
spacing of longitudinals
Type 3: Welded deformed wire reinforcement, deformed wire,
deformed bars, or any reinforcement
...

Questions, Comments and Discussion