Standard Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster

ABSTRACT
This specification covers the minimum requirements for, and methods of, application of gypsum veneer base for gypsum veneer plasters. Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories. The materials shall be classified as follows: gypsum base for veneer plasters; gypsum backing board for coreboard; special fire-retardant gypsum base; foil-backed gypsum base; gypsum veneer plaster; nails; non-load bearing steel; load bearing steel; steel framing, non-load bearing; accessories; adhesives; steel framing load bearing; and wood framing. The maximum spacing of framing members for singly gypsum base construction shall be not more than then specified values. Application of gypsum base, single-ply gypsum base, adhesive-mechanical fastener, foil-backed gypsum base, two-ply gypsum base, and application over existing surfaces shall be indicated. Solid gypsum base partitions shall include face ply, core, and runners. Direct adhesive application shall be used only on interior masonry or concrete walls above grade, or inside of exterior masonry cavity walls. Gypsum base application over steel framing and furring shall include screw application, framing space, and screw spacing. Gypsum base applied to the soffit of arches shall be carefully bent into place and shall conform to the specified values of bending radii.
SCOPE
1.1 This specification covers the minimum requirements for, and methods of, application of gypsum veneer base for gypsum veneer plasters.
1.2 Gypsum veneer base shall not be used as a base for direct adhesive application of ceramic, metal, or plastic tile in areas exposed to abnormal moisture or humidity or temperature.
1.3 Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories.
1.4 Where a specific degree of sound control is required for veneer plaster assemblies and constructions, details of construction shall be in accordance with official reports of tests conducted in recognized sound testing laboratories in accordance with the applicable sound tests, Test Method C 423, Test Method E 90, or Test Method E 492.
1.5 Where this specification is more stringent (size or thickness of framing; spacing of fasteners) than the fire-rated construction, this specification shall govern; otherwise, the construction described in the fire test report shall govern.
1.6 Unheated spaces above gypsum veneer base ceilings shall be properly ventilated (see ).
1.7 The values stated in inch-pound units are to be regarded as the standard. The SI (metric) values given in parentheses are approximate and are provided for information purposes only.
1.8 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

General Information

Status
Historical
Publication Date
30-Sep-2004
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C844-04 - Standard Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C844 – 04
Standard Specification for
Application of Gypsum Base to Receive
1
Gypsum Veneer Plaster
This standard is issued under the fixed designation C844; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* 2. Referenced Documents
2
1.1 Thisspecificationcoverstheminimumrequirementsfor, 2.1 ASTM Standards:
andmethodsof,applicationofgypsumveneerbaseforgypsum C11 TerminologyRelatingtoGypsumandRelatedBuilding
veneer plasters. Materials and Systems
1.2 Gypsum veneer base shall not be used as a base for C423 Test Method for Sound Absorption and Sound Ab-
direct adhesive application of ceramic, metal, or plastic tile in sorption Coefficients by the Reverberation Room Method
areas exposed to abnormal moisture or humidity or tempera- C514 Specification for Nails for theApplication of Gypsum
ture. Board
1.3 Details of construction for a specific assembly to C587 Specification for Gypsum Veneer Plaster
achieve the required fire resistance shall be obtained from C588/C588M Specification for Gypsum Base for Veneer
3
reports of fire-resistance tests, engineering evaluations, or Plasters
listings from recognized fire testing laboratories. C754 Specification for Installation of Steel Framing Mem-
1.4 Where a specific degree of sound control is required for bers to Receive Screw-Attached Gypsum Panel Products
veneer plaster assemblies and constructions, details of con- C954 Specification for Steel Drill Screws for the Applica-
struction shall be in accordance with official reports of tests tion of Gypsum Panel Products or Metal Plaster Bases to
conducted in recognized sound testing laboratories in accor- Steel Studs from 0.033 in. (0.84 mm) to 0.112 in. (2.84
dance with the applicable sound tests, Test Method C423, Test mm) in Thickness
Method E90, or Test Method E492. C955 Specification for Load-Bearing (Transverse and
1.5 Where this specification is more stringent (size or Axial) Steel Studs, Runners (Tracks), and Bracing or
thickness of framing; spacing of fasteners) than the fire-rated Bridging for ScrewApplication of Gypsum Panel Products
construction, this specification shall govern; otherwise, the and Metal Plaster Bases
construction described in the fire test report shall govern. C1002 Specification for Steel Self-PiercingTapping Screws
1.6 Unheated spaces above gypsum veneer base ceilings for the Application of Gypsum Panel Products or Metal
shall be properly ventilated (see Appendix X3). Plaster Bases to Wood Studs or Steel Studs
1.7 The values stated in inch-pound units are to be regarded C1007 Specification for Installation of Load Bearing
as the standard.The SI (metric) values given in parentheses are (Transverse and Axial) Steel Studs and Related Accesso-
approximate and are provided for information purposes only. ries
1.8 The text of this standard references notes and footnotes C1047 Specification forAccessories for GypsumWallboard
which provide explanatory material. These notes and footnotes and Gypsum Veneer Base
(excluding those in tables and figures) shall not be considered C1546 Guide for Installation of Gypsum Products in Con-
as requirements of the standard. cealed Radiant Ceiling Heating Systems
1
This specification is under the jurisdiction of ASTM Committee C11 on
2
Gypsum and Related Building Material and Systems, and is the direct responsibility For referenced ASTM standards, visit the ASTM website, www.astm.org, or
of Subcommittee C11.03 on Specifications for Application of Gypsum and Other contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Products in Assemblies. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Oct. 1, 2004. Published October 2004. Originally the ASTM website.
3
approved in 1978. Last previous edition approved in 1999 as C844 – 99. DOI: Withdrawn. The last approved version of this historical standard is referenced
10.1520/C0844-04. on www.astm.org.
*ASummary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C844 – 04
E90 Test Method for Laboratory Measurement of Airborne 4.10 Steel Framing, Non-load bearing—Specification C645
Sound Transmission Loss of Building Partitions and Ele- for the specified design criteria.
ments 4.11 Accessories—Specification C1047.
E492 Test Method for Laboratory Measurement of Impact 4.12 Adhesive:
Sound Trans
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.