ASTM E1822-02b
(Test Method)Standard Test Method for Fire Testing of Stacked Chairs
Standard Test Method for Fire Testing of Stacked Chairs
SCOPE
1.1 This is a fire-test-response standard.
1.2 This test method provides a means of determining the burning behavior of stacking chairs used in public occupancies by measuring specific fire-test responses when a stack of chairs is subjected to a specified flaming ignition source under well ventilated conditions.
1.3 This test method is limited to stacked chairs.
1.4 Test data are obtained describing the burning behavior following application of a specific ignition source, from ignition until all burning has ceased, a period of 1 h has elapsed, or flashover under test conditions appears inevitable.
1.5 This test method does not provide information on the fire performance of stacked chairs under fire conditions other than those conditions specified in this test method. In particular, this test method does not apply to smoldering ignition by cigarettes. See 5.11 for further information.
1.6 The rate of heat release of the burning test specimen is measured by an oxygen consumption method. See 5.11.4 for further information.
1.7 Other measurements are the production of light-obscuring smoke and the concentrations of certain toxic gas species in the combustion gases. See 5.11.5 for further information.
1.8 The burning behavior is documented visually by photographic or video recordings.
1.9 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.
1.10 Fire testing of products and materials is inherently hazardous, and adequate safeguards for personnel and property shall be employed in conducting these tests. This test method may involve hazardous materials, operations, and equipment.
1.11 Use the SI system of units in referee decisions; see Practice E 380. The units given in parentheses are for information only.
1.12 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: E 1822 – 02b
Standard Test Method for
1
Fire Testing of Stacked Chairs
This standard is issued under the fixed designation E1822; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 1.12 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
1.1 This is a fire-test-response standard.
responsibility of the user of this standard to establish appro-
1.2 This test method provides a means of determining the
priate safety and health practices and determine the applica-
burningbehaviorofstackingchairsusedinpublicoccupancies
bility of regulatory limitations prior to use.
bymeasuringspecificfire-testresponseswhenastackofchairs
is subjected to a specified flaming ignition source under well
2. Referenced Documents
ventilated conditions.
2.1 ASTM Standards:
1.3 This test method is limited to stacked chairs.
2
D123 Terminology Relating to Textiles
1.4 Test data are obtained describing the burning behavior
E84 Test Method for Surface Burning Characteristics of
following application of a specific ignition source, from
3
Building Materials
ignition until all burning has ceased, a period of1hhas
3
E176 Terminology of Fire Standards
elapsed, or flashover under test conditions appears inevitable.
E380 Practice for Use of the International System of Units
1.5 This test method does not provide information on the
4
(SI) (the Modernized Metric System)
fire performance of stacked chairs under fire conditions other
E800 Guide for Measurement of Gases Present or Gener-
than those conditions specified in this test method. In particu-
3
ated During Fires
lar, this test method does not apply to smoldering ignition by
E1354 Test Method for Heat and Visible Smoke Release
cigarettes. See 5.11 for further information.
Rates for Materials and Products Using an Oxygen Con-
1.6 The rate of heat release of the burning test specimen is
3
sumption Calorimeter
measured by an oxygen consumption method. See 5.11.4 for
E1474 TestMethodforDeterminingtheHeatReleaseRate
further information.
of Upholstered Furniture and Mattress Components or
1.7 Other measurements are the production of light-
Composites Using a Bench Scale Oxygen Consumption
obscuring smoke and the concentrations of certain toxic gas
3
Calorimeter
species in the combustion gases. See 5.11.5 for further infor-
E1537 Test Method for Fire Testing of Upholstered Furni-
mation.
3
ture
1.8 The burning behavior is documented visually by photo-
3
E1590 Test Method for Fire Testing of Mattresses
graphic or video recordings.
2.2 ISO Standards:
1.9 This standard is used to measure and describe the
5
ISO 3261 Fire Tests—Vocabulary
response of materials, products, or assemblies to heat and
ISO 4880 Burning Behaviour of Textiles and Textile
flame under controlled conditions, but does not by itself
5
Products—Vocabulary
incorporate all factors required for fire hazard or fire risk
ISO 9705 Fire Tests—Full Scale Room Test for Surface
assessment of the materials, products or assemblies under
5
Products
actual fire conditions.
2.3 UL Standards:
1.10 Fire testing of products and materials is inherently
6
UL 1056 Fire Test of Upholstered Furniture
hazardous,andadequatesafeguardsforpersonnelandproperty
6
UL 1895 Fire Test of Mattresses
shall be employed in conducting these tests. This test method
2.4 CA Standards:
may involve hazardous materials, operations, and equipment.
CATB129, FlammabilityTestProcedureforMattressesfor
1.11 Use the SI system of units in referee decisions; see
Practice E380. The units given in parentheses are for infor-
mation only.
2
Annual Book of ASTM Standards, Vol 07.01.
3
Annual Book of ASTM Standards, Vol 04.07.
1 4
This test method is under the jurisdiction of ASTM Committee E05 on Fire Annual Book of ASTM Standards, Vol 14.02.
5
Standards and is the direct responsibility of Subcommittee E05.15 on Furnishings Available from International Standardization Organization, P.O. Box 56,
and Contents. CH-1211, Geneva 20, Switzerland.
6
Current edition approved Sept. 10, 2002. Published November 2002. Originally Available from Underwriters Laboratories, Inc., 333 Pfingsten Road, North-
published as E1822–96. Last previous edition E1822–02a. brook, IL 60062.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
E 1822 – 02b
7
Use in Public Buildings 4.2 In Test Configurations A and B, the test specimen is
CA TB 133, Flammability Test Procedure for Seating Fur- placed on a
...