Standard Test Methods of Testing Cellular Glass Insulation Block

SIGNIFICANCE AND USE
4.1 From a general standpoint, these test methods outline the particular points which have to be taken into account when applying ASTM standard test methods to the case of cellular glass insulating block.
SCOPE
1.1 These test methods cover the testing of cellular glass insulation block for density, water absorption, compressive strength, flexural strength at ambient temperature; preparation for chemical analysis; and thermal conductivity measurements.  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Aug-2016
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C240-16 - Standard Test Methods of Testing Cellular Glass Insulation Block
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM C240-16 - Standard Test Methods of Testing Cellular Glass Insulation Block
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C240 − 16
Standard Test Methods of
1
Testing Cellular Glass Insulation Block
This standard is issued under the fixed designation C240; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D226/D226MSpecification for Asphalt-Saturated Organic
Felt Used in Roofing and Waterproofing
1.1 These test methods cover the testing of cellular glass
D4869/D4869M Specification for Asphalt-Saturated Or-
insulation block for density, water absorption, compressive
ganic Felt Underlayment Used in Steep Slope Roofing
strength, flexural strength at ambient temperature; preparation
2.2 ISO Standard:
forchemicalanalysis;andthermalconductivitymeasurements.
ISO 3951Sampling Procedure and Charts for Inspection by
1.2 Thevaluesstatedininch-poundunitsaretoberegarded
3
Variables for Percent Nonconforming
as standard. The values given in parentheses are mathematical
2.3 Military Standard:
conversions to SI units that are provided for information only
MIL-I-24244SpecificationInsulationMaterialswithSpecial
and are not considered standard.
4
Corrosion, Chloride, and Fluoride Requirements
1.3 This standard does not purport to address all of the
2.4 Other Standard:
safety concerns, if any, associated with its use. It is the
NRC 1.36Nonmetallic Thermal Insulation for Austenitic
responsibility of the user of this standard to establish appro-
5
Stainless Steel
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
3. Terminology
2. Referenced Documents
3.1 Definitions—Terminology C168 shall be considered as
2
applying to the terms considered in these test methods.
2.1 ASTM Standards:
C165TestMethodforMeasuringCompressivePropertiesof
4. Significance and Use
Thermal Insulations
C168Terminology Relating to Thermal Insulation 4.1 From a general standpoint, these test methods outline
the particular points which have to be taken into account when
C177Test Method for Steady-State Heat Flux Measure-
ments and Thermal Transmission Properties by Means of applying ASTM standard test methods to the case of cellular
glass insulating block.
the Guarded-Hot-Plate Apparatus
C203Test Methods for Breaking Load and Flexural Proper-
5. Test Methods
ties of Block-Type Thermal Insulation
C303Test Method for Dimensions and Density of Pre-
5.1 General Sample Preparation—All tests have to be run
formed Block and Board–Type Thermal Insulation
on dry specimens. In case of need, the sample must be
C390Practice for Sampling and Acceptance of Thermal
unpacked and stored in a dry place in such a way that all
Insulation Lots
surfaces are exposed to the ambient air for a minimum of 24
C518Test Method for Steady-State Thermal Transmission
hours before testing.
Properties by Means of the Heat Flow Meter Apparatus
5.2 Density—DeterminethedensityinaccordancewithTest
C871Test Methods for ChemicalAnalysis of Thermal Insu-
Method C303. Preferably, the density shall be measured on a
lationMaterialsforLeachableChloride,Fluoride,Silicate,
full block, 18 by 24 in. (450 by 600 mm) by full thickness.
and Sodium Ions
5.2.1 It shall be noted that density is interesting as such for
calculation of insulated equipment load and because it has
1
These test methods are under the jurisdiction of ASTM Committee C16 on
influence on the other important properties of cellular glass.
Thermal Insulation and are the direct responsibility of Subcommittee C16.32 on
Mechanical Properties.
Current edition approved Sept. 1, 2016. Published September 2016. Originally
3
approved in 1950. Last previous edition approved in 2012 as C240–08 (2012). Available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St.,
DOI: 10.1520/C0240-16. 4th Floor, New York, NY 10036, http://www.ansi.org.
2 4
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
5
Standards volume information, refer to the standard’s Document Summary page on Available from Director of Regulatory Standards, US Atomic Energy
the ASTM website. Commission, Washington, DC 20545.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C240 − 16
6
But it shall not be considered in itself as a criterion for 1007. Therepeatabilityorsingle-laboratoryoperatorprecision
2
acceptance in the case of cellular glass. is 60.00060 g/cm or 60.030 volume% (61S)
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C240 − 08 (Reapproved 2012) C240 − 16
Standard Test Methods of
1
Testing Cellular Glass Insulation Block
This standard is issued under the fixed designation C240; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 These test methods cover the testing of cellular glass insulation block for density, water absorption, compressive strength,
flexural strength at ambient temperature; preparation for chemical analysis; and thermal conductivity measurements.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C165 Test Method for Measuring Compressive Properties of Thermal Insulations
C168 Terminology Relating to Thermal Insulation
C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the
Guarded-Hot-Plate Apparatus
C203 Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation
C303 Test Method for Dimensions and Density of Preformed Block and Board–Type Thermal Insulation
C390 Practice for Sampling and Acceptance of Thermal Insulation Lots
C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
C871 Test Methods for Chemical Analysis of Thermal Insulation Materials for Leachable Chloride, Fluoride, Silicate, and
Sodium Ions
C226D226/D226M Specification for Air-Entraining Additions for Use in the Manufacture of Air-Entraining Hydraulic
CementAsphalt-Saturated Organic Felt Used in Roofing and Waterproofing
D4869/D4869M Specification for Asphalt-Saturated Organic Felt Underlayment Used in Steep Slope Roofing
2.2 ISO Standard:
3
ISO 3951 Sampling Procedure and Charts for Inspection by Variables for Percent Nonconforming
2.3 Military Standard:
4
MIL-I-24244 Specification Insulation Materials with Special Corrosion, Chloride, and Fluoride Requirements
2.4 Other Standard:
5
NRC 1.36 Nonmetallic Thermal Insulation for Austenitic Stainless Steel
3. Terminology
3.1 Definitions—Terminology C168 shall be considered as applying to the terms considered in these test methods.
1
These test methods are under the jurisdiction of ASTM Committee C16 on Thermal Insulation and are the direct responsibility of Subcommittee C16.32 on Mechanical
Properties.
Current edition approved Sept. 1, 2012Sept. 1, 2016. Published November 2012September 2016. Originally approved in 1950. Last previous edition approved in 20082012
ε1
as C240 – 08 (2012). . DOI: 10.1520/C0240-08R12.10.1520/C0240-16.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.
4
Available from DLA Document Services, Building 4/D, 700 Robbins Ave., Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
5
Available from Director of Regulatory Standards, US Atomic Energy Commission, Washington, DC 20545.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C240 − 16
4. Significance and Use
4.1 From a general standpoint, these test methods outline the particular points which have to be taken into account when
applying ASTM standard test methods to the case of cellular glass insulating block.
5. Test Methods
5.1 General Sample Preparation—All tests have to be run on dry specimens. In case of need, the sample must be unpacked and
stored in a dry place in such a way that all surfaces are exposed to the ambient air for a minimum of 24 hours before testing.
5.2 Density—Determine the density in accordance with Test Method C303. Pre
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.