Standard Specification for PB Exterior Insulation and Finish Systems

ABSTRACT
This specification covers PB Exterior Insulation and Finish Systems (EIFS) defined as an exterior, non-bearing wall covering providing a weather-resistant exterior wall envelope on walls required to be combustible or noncombustible, fireresistance-rated or nonfire-resistance-rated. Further, PB EIFS is a system described as being applied over insulation board, an adhesive or mechanical attachment of the insulation board to a substrate, or both, glass fiber reinforcing mesh, a base coat on the face of the insulation board, and a textured protective finish coat. The following tests shall be performed in accordance to the following test methods: accelerated weathering; freeze/thaw; salt spray resistance; tensile bond adhesion; water penetration; water resistance; physical properties and requirements for EPS; alkali resistance of reinforcing mesh; fire endurance; full-scale multi-story fire test; and ignition resistance.
SCOPE
1.1 This specification covers PB Exterior Insulation and Finish Systems (EIFS) defined as an exterior, non-bearing wall covering providing a weather-resistant exterior wall envelope on walls required to be combustible or noncombustible, fire-resistance-rated or nonfire-resistance-rated. Further, PB EIFS is a system described as being applied over expanded polystyrene or polyisocyanurate insulation board, an adhesive or mechanical attachment of the insulation board to a substrate, or both, glass fiber reinforcing mesh, a base coat on the face of the insulation board, and a textured protective finish coat.  
1.2 This specification does not cover Class PB EIFS with drainage.
1.3 This specification qualifies EIFS products for use in normal service conditions and is not for evaluating in service EIFS installations.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Mar-2009
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM E2568-09e1 - Standard Specification for PB Exterior Insulation and Finish Systems
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM E2568-09e1 - Standard Specification for PB Exterior Insulation and Finish Systems
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation:E2568 −09
Standard Specification for
1
PB Exterior Insulation and Finish Systems
This standard is issued under the fixed designation E2568; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—Editorial changes were made throughout to comply with ASTM’s policy on Units in Standards (April 2009).
1. Scope C578 Specification for Rigid, Cellular Polystyrene Thermal
Insulation
1.1 This specification covers PB Exterior Insulation and
C1289 Specification for Faced Rigid Cellular Polyisocyanu-
Finish Systems (EIFS) defined as an exterior, non-bearing wall
rate Thermal Insulation Board
covering providing a weather-resistant exterior wall envelope
D2247 Practice for Testing Water Resistance of Coatings in
on walls required to be combustible or noncombustible, fire-
100 % Relative Humidity
resistance-rated or nonfire-resistance-rated. Further, PB EIFS
E84 Test Method for Surface Burning Characteristics of
is a system described as being applied over expanded polysty-
Building Materials
rene or polyisocyanurate insulation board, an adhesive or
E119 Test Methods for Fire Tests of Building Construction
mechanicalattachmentoftheinsulationboardtoasubstrate,or
and Materials
both,glassfiberreinforcingmesh,abasecoatonthefaceofthe
E330 Test Method for Structural Performance of Exterior
insulation board, and a textured protective finish coat.
Windows,Doors,SkylightsandCurtainWallsbyUniform
1.2 This specification does not cover Class PB EIFS with
Static Air Pressure Difference
drainage.
E331 Test Method for Water Penetration of Exterior
1.3 This specification qualifies EIFS products for use in Windows, Skylights, Doors, and Curtain Walls by Uni-
form Static Air Pressure Difference
normal service conditions and is not for evaluating in service
EIFS installations. E2098 Test Method for Determining Tensile Breaking
StrengthofGlassFiberReinforcingMeshforUseinClass
1.4 The values stated in inch-pound units are to be regarded
PB Exterior Insulation and Finish Systems (EIFS), after
as standard. The values given in parentheses are mathematical
Exposure to a Sodium Hydroxide Solution
conversions to SI units that are provided for information only
E2110 Terminology for Exterior Insulation and Finish Sys-
and are not considered standard.
tems (EIFS)
1.5 This standard does not purport to address all of the
E2134 Test Method for Evaluating the Tensile-Adhesion
safety concerns, if any, associated with its use. It is the
Performance of an Exterior Insulation and Finish System
responsibility of the user of this standard to establish appro-
(EIFS)
priate safety and health practices and determine the applica-
E2485 Test Method for Freeze/Thaw Resistance of Exterior
bility of regulatory limitations prior to use.
Insulation and Finish Systems (EIFS) and Water Resistive
Barrier Coatings
2. Referenced Documents
E2486 Test Method for Impact Resistance of Class PB and
2
2.1 ASTM Standards:
PI Exterior Insulation and Finish Systems (EIFS)
B117 Practice for Operating Salt Spray (Fog) Apparatus
G23 Practice for Operating Light-Exposure Apparatus
C297/C297M Test Method for Flatwise Tensile Strength of
(Carbon-Arc Type) With and Without Water for Exposure
3
Sandwich Constructions
of Nonmetallic Materials (Withdrawn 2000)
G26 Practice for Operating Light-Exposure Apparatus
(Xenon-Arc Type) With and Without Water for Exposure
1
This test method is under the jurisdiction of ASTM Committee E06 on
of Nonmetallic Materials (Discontinued 2001) (With-
Performance of Buildings and is the direct responsibility of Subcommittee E06.58
3
drawn 2000)
on Exterior Insulation and Finish Systems (EIFS).
Current edition approved April 1, 2009. Published May 2009. Originally
G153 Practice for Operating Enclosed Carbon Arc Light
approved in 2007. Last previous edition approved in 2007 as E2568 – 07. DOI:
Apparatus for Exposure of Nonmetallic Materials
10.1520/E2568-09E01.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on The last approved version of this historical standard is referenced on
the ASTM website. www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
´1
E2568−09
G155 Practice for Operating XenonArc LightApparatus for 5. Performance Requirements
Exposure of Non-Metallic Materials
5.1 The system and its components shall meet or exceed the
4
2.2
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
ϵ1
Designation:E 2568–07 Designation: E2568 – 09
Standard Specification for
1
PB Exterior Insulation and Finish Systems
This standard is issued under the fixed designation E2568; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (ϵ) indicates an editorial change since the last revision or reapproval.
1
ϵ NOTE—Editorial changes were made throughout to comply with ASTM’s policy on Units in Standards (April 2009).
1. Scope
1.1 This specification covers PB Exterior Insulation and Finish Systems (EIFS) defined as an exterior, non-bearing wall
covering providing a weather-resistant exterior wall envelope on walls required to be combustible or noncombustible,
fire-resistance-ratedornonfire-resistance-rated.Further,PBEIFSisasystemdescribedasbeingappliedoverexpandedpolystyrene
or polyisocyanurate insulation board, an adhesive or mechanical attachment of the insulation board to a substrate, or both, glass
fiber reinforcing mesh, a base coat on the face of the insulation board, and a textured protective finish coat.
1.2 This specification does not cover Class PB EIFS with drainage.
1.3 This specification qualifies EIFS products for use in normal service conditions and is not for evaluating in service EIFS
installations.
1.4
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
B117 Practice for Operating Salt Spray (Fog)(Fog) Apparatus
C297/C297M Test Method for Flatwise Tensile Strength of Sandwich Constructions
C578 Specification for Rigid, Cellular Polystyrene Thermal Insulation
C1289 Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
D2247 Practice for Testing Water Resistance of Coatings in 100%100 % Relative Humidity
E84 Test Method for Surface Burning Characteristics of Building Materials
E119 Test Methods for Fire Tests of Building Construction and Materials
E330 Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform StaticAir
Pressure Difference
E331 Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air
Pressure Difference
E631Terminology of Building Constructions
E2098 Test Method for Determining Tensile Breaking Strength of Glass Fiber Reinforcing Mesh for Use in Class PB Exterior
Insulation and Finish Systems (EIFS), after Exposure to a Sodium Hydroxide Solution
E2110 Terminology for Exterior Insulation and Finish Systems (EIFS)(EIFS)
E2134 TestMethodforEvaluatingtheTensile-AdhesionPerformanceofanExteriorInsulationandFinishSystem(EIFS)(EIFS)
E2485 Test Method for Freeze/Thaw Resistance of Exterior Insulation and Finish Systems (EIFS) and Water Resistive Barrier
Coatings
E2486 Test Method for Impact Resistance of Class PB and PI Exterior Insulation and Finish Systems (EIFS)
1
This test method is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.58 on Exterior
Insulation and Finish Systems (EIFS).
Current edition approved Sept. 1, 2007. Published September 2007.
Current edition approved April 1, 2009. Published May 2009. Originally approved in 2007. Last previous edition approved in 2007 as E2568 – 07. DOI:
10.1520/E2568-09E01.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
ϵ1
E2568 – 09
G23 PracticeforOperatingLight-ExposureApparatus(Carbon-ArcType)WithandWithoutWaterforExposureofNonmetallic
3
Materials
G26 Practice for Operating Light-ExposureApparatus (Xenon-ArcType)With andWithoutWater for Exposure of Nonmetallic
0
Materials (Discontinued 2001)
...

Questions, Comments and Discussion