Standard Practice for Preparing Coupons for Flexural and Washout Tests on Glass Fiber Reinforced Concrete

SIGNIFICANCE AND USE
3.1 Flexural strengths, as determined by Test Method C947, are used for quality control and design of GFRC products and may be used to verify compliance with specifications and to collect data in research and development programs. It is, therefore, important that coupons be prepared according to a standard practice. The coupons are used to make test specimens for Test Method C947 and for Test Method C1229 to determine the amount of glass fiber reinforcement per unit volume of GFRC for quality control purposes.
SCOPE
1.1 This practice covers preparation of test coupons to be used in tests of plant manufactured thin-section glass fiber reinforced concrete (GFRC).  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Apr-2023
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C1228-96(2023) - Standard Practice for Preparing Coupons for Flexural and Washout Tests on Glass Fiber Reinforced Concrete
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: C1228 − 96 (Reapproved 2023)
Standard Practice for
Preparing Coupons for Flexural and Washout Tests on
Glass Fiber Reinforced Concrete
This standard is issued under the fixed designation C1228; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope may be used to verify compliance with specifications and to
collect data in research and development programs. It is,
1.1 This practice covers preparation of test coupons to be
therefore, important that coupons be prepared according to a
used in tests of plant manufactured thin-section glass fiber
standard practice. The coupons are used to make test specimens
reinforced concrete (GFRC).
for Test Method C947 and for Test Method C1229 to determine
1.2 The values stated in inch-pound units are to be regarded
the amount of glass fiber reinforcement per unit volume of
as standard. The values given in parentheses are mathematical
GFRC for quality control purposes.
conversions to SI units that are provided for information only
and are not considered standard.
4. Apparatus
1.3 This standard does not purport to address all of the
4.1 Form—The form shall be rectangular in shape; made
safety concerns, if any, associated with its use. It is the
from wood, fiberglass reinforced plastic (FRP), GFRC, or steel
responsibility of the user of this standard to establish appro-
with dimensions of ⁄2 in. (13 mm) deep by 18 in. (450 mm)
priate safety, health, and environmental practices and deter-
wide and 48 in. (1200 mm) long.
mine the applicability of regulatory limitations prior to use.
4.2 Steel Trowel, at least 20 in. (500 mm) long.
1.4 This international standard was developed in accor-
4.3 Serrated Roller, with handle.
dance with internationally recognized principles on standard-
ization established in the Decision on Principles for the
4.4 Strike-Off Bar (screed), at least 20 in. (500 mm) long,
Development of International Standards, Guides and Recom-
for leveling and thickness control of specimens.
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee. 5. Sampling
5.1 Sampling shall be in accordance with governing speci-
2. Referenced Documents
fications.
2.1 ASTM Standards:
C947 Test Method for Flexural Properties of Thin-Section
6. Procedure
Glass-Fiber-Reinforced Concrete (Using Simple Beam
6.1 For plant manufactured product quality control
With Third-Point Loading)
purposes, spray the glass fiber reinforced material into the test
C1229 Test Method for Determination of Glass Fiber Con-
form using the same method as used in production. The
tent in Glass Fiber Reinforced Concrete (GFRC) (Wash-
methods and conditions should be the same as for pr
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.