Standard Specification for Fiber-Reinforced Gypsum Panel

SCOPE
1.1 This specification covers fiber-reinforced gypsum panels described in .
1.1.1 Interior Fiber-Reinforced Gypsum Panels are designed to be used for walls, ceilings, or partitions and affords a suitable surface to receive decoration.
1.1.2 Water-Resistant Fiber-Reinforced Gypsum Backing Panels are designed primarily to be used as a base for the application of ceramic or plastic tile on walls or ceilings. This product is also suitable for decoration.
1.1.3 Exterior Fiber-Reinforced Gypsum Soffit Panels are designed for use on exterior soffits and carport ceilings that are completely protected from contact with liquid water.
1.1.4 Water-Resistant Exterior Fiber-Reinforced Gypsum Sheathing Panels are designed for use as sheathing on buildings.
1.2 Specifications applicable to all fiber-reinforced gypsum panels are located in Sections 1-4 and 9-11 except as modified by applicable product sections. Specifications applicable to specific panels are located in the following sections:
1.3 The values stated in either inch-pound units or SI (metric) are to be regarded separately as the standard. Within the text, the SI units are shown in brackets. The values stated in each system shall be used independently of the other. Values from the two systems shall not be combined.
1.4 The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes shall not be considered as requirements of the standard.

General Information

Status
Historical
Publication Date
31-Jul-2007
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1278/C1278M-07 - Standard Specification for Fiber-Reinforced Gypsum Panel
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 1278/C 1278M – 07
Standard Specification for
1
Fiber-Reinforced Gypsum Panel
This standard is issued under the fixed designation C 1278/C 1278M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope* 2. Referenced Documents
2
1.1 This specification covers fiber-reinforced gypsum pan- 2.1 ASTM Standards:
els described in 1.1.1-1.1.4. C11 Terminology Relating to Gypsum and Related Build-
1.1.1 Interior Fiber-Reinforced Gypsum Panels are de- ing Materials and Systems
signed to be used for walls, ceilings, or partitions and affords C 22/C 22M Specification for Gypsum
a suitable surface to receive decoration. C 473 Test Methods for Physical Testing of Gypsum Panel
1.1.2 Water-Resistant Fiber-Reinforced Gypsum Backing Products
Panels are designed primarily to be used as a base for the C 645 Specification for Nonstructural Steel Framing Mem-
application of ceramic or plastic tile on walls or ceilings. This bers
product is also suitable for decoration. C 1264 Specification for Sampling, Inspection, Rejection,
1.1.3 Exterior Fiber-Reinforced Gypsum Soffıt Panels are Certification, Packaging, Marking, Shipping, Handling,
designed for use on exterior soffits and carport ceilings that are and Storage of Gypsum Panel Products
completely protected from contact with liquid water. E84 Test Method for Surface Burning Characteristics of
1.1.4 Water-Resistant Exterior Fiber-Reinforced Gypsum Building Materials
Sheathing Panels are designed for use as sheathing on build- E 96/E 96M Test Methods for Water Vapor Transmission of
ings. Materials
1.2 Specifications applicable to all fiber-reinforced gypsum E119 Test Methods for Fire Tests of Building Construction
panels are located in Sections 1-4 and 9-11 except as modified and Materials
by applicable product sections. Specifications applicable to
3. Terminology
specific panels are located in the following sections:
3.1 Definitions—Definitions of terms shall be in accordance
Interior Fiber-Reinforced Gypsum Panels 5
Water-Resistant Fiber-Reinforced Gypsum Backing Panels 6
with TerminologyC11.
Exterior Fiber-Reinforced Gypsum Soffit Panels 7
3.1.1 nominal thickness, n—the manufacturer-stated frac-
Water-Resistant Exterior Fiber-Reinforced Gypsum Sheathing Panels 8
tional value of thickness of the gypsum panel product ex-
1.3 The values stated in either inch-pound units or SI
pressed in decimal value to the nearest one-thousandth (0.001)
(metric) are to be regarded separately as the standard. Within
of an inch.
the text, the SI units are shown in brackets. The values stated
in each system shall be used independently of the other. Values 4. Materials and Manufacture
from the two systems shall not be combined.
4.1 Fiber-reinforced gypsum panels shall consist essentially
1.4 The text of this specification references notes and
of gypsum with fibers dispersed throughout.
footnotes that provide explanatory material. These notes and
4.1.1 Gypsum—Specification C 22/C 22M.
footnotes shall not be considered as requirements of the
4.1.2 Fibers—Cellulose, derived from paper, paperboard
standard.
stock, wood, or other organic material.
4.2 Thebacksurfaceoffoil-backedfiber-reinforcedgypsum
panels shall in addition be covered with aluminum foil.
1
This specification is under the jurisdiction of ASTM Committee C11 on
Gypsum and Related Building Materials and Systems and is the direct responsi-
2
bility of Subcommittee C11.01 on Specifications and Test Methods for Gypsum For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Products. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Current edition approved Aug. 1, 2007. Published September 2007. Originally Standards volume information, refer to the standard’s Document Summary page on
approvedin1994.Lastpreviouseditionapprovedin2006asC 1278/C 1278M – 06. the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C 1278/C 1278M – 07
4.3 Water-resistant fiber-reinforced gypsum panels shall be 5.1.3 Nail Pull Resistance—The specimens shall have an
treated with a material that imparts water resistance through- average nail pull resistance of not less than the following:
out.
Thickness, in. [mm] Method B, lbf [N]
1
⁄2 [12.7] 120 [535]
4.4 Fiber-reinforced gypsum panels, type X (special fire-
5
⁄8 [15.9] 145 [645]
resistant)designatesfiber-reinforcedgypsumpanelscomplying
5.2 Dimensions and Tolerances of Interi
...